TRIBOCHEMISTRY AND SIDE EFFECT OF SLIDING-INDUCED DAMAGE ON REDUCED GRAPHENE OXIDE IN JOINT PROSTHESIS. CELLULAR RESPONSE TO WORN SURFACES AND IN VIVO REACTIONS TO WEAR DEBRIS

RTI2018-101506-B-C31

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos I+D+i Retos de Investigación
Año convocatoria 2018
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario AGENCIA ESTATAL CONSEJO SUPERIOR DE INVESTIGACIONES CIENTIFICAS (CSIC)

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Dataset for the paper "Barrier Graphene Oxide on a CoCr Alloy via Silane/GO Covalent Bonding and Its Electrochemical Behavior in a Simulated Synovial Fluid Electrolyte"

  • Sánchez-López, Luna
  • Chico, Belén
  • Escudero Rincón, María Lorenza
  • Lozano, R.M.
  • García-Alonso, M. C.
[EN] The electrochemical behaviour of each layer deposited on CoCr surfaces was examined by electrochemical impedance spectroscopy (EIS) for 7 days in 3 g/L hyaluronic acid (HA) aqueous solution. Impedance tests were performed in a three-electrode electrochemical cell with the modified CoCr surfaces acting as the working electrode, a Pt wire acting as counter electrode, and Ag/AgCl (3 M KCl) as a reference electrode. The testing area of the working electrode for all electrochemical tests was 0.39 cm2. An Autolab32 potentiostat/galvanostat was used to generate a sinusoidal wave of 10 mV amplitude in the frequency range 100 kHz to 1 mHz, logarithmically spaced by 5 points/decade, which was applied at the corrosion potential Ecorr. Nova software was used for the data acquisition. All the tests were performed in duplicate. The dataset includes only the experimental data used in the paper. The following files for each surface modification and each immersion time are included: CoCr, CoCr-OH, CoCr-OH-Si45, CoCr-OH-Si45-GO12h, CoCr-OH-Si45-GO24h, CoCr-OH-Si75, CoCr-OH-Si75-GO12h, CoCr-OH-Si75-GO24h. Each file is composed of 5 columns: frequency, real impedance (Z'), imaginary impedance (Z''), Impedance modulus (Z) and phase angle (Phase). All files are in open extension such as .txt and are protected by a Creative Commons Attribution 4.0 International (CC BY 4.0) licence. [ES] El comportamiento electroquímico de cada capa depositada en superficies de CoCr fue examinado mediante espectroscopía de impedancia electroquímica (EIS) durante 7 días sumergidas en una solución acuosa de ácido hialurónico (HA) al 3 g/L. Las pruebas de impedancia se realizaron en una celda electroquímica de tres electrodos con las superficies modificadas de CoCr actuando como electrodo de trabajo, un alambre de Pt actuando como electrodo auxiliar y Ag/AgCl (3 M KCl) como electrodo de referencia. El área de ensayo del electrodo de trabajo para todas las pruebas electroquímicas fue de 0.39 cm2. Se utilizó un potenciostato/galvanostato Autolab32 para generar una onda sinusoidal de amplitud de 10 mV en el rango de frecuencia de 100 kHz a 1 mHz, espaciada logarítmicamente por 5 puntos/década, que se aplicó en el potencial de corrosión Ecorr. Se utilizó el software Nova para la adquisición de datos. Todas las pruebas se realizaron por duplicado. El conjunto de datos incluye solo los datos experimentales utilizados en el artículo. Los siguientes archivos para cada modificación de superficie y cada tiempo de inmersión están incluidos: CoCr, CoCr-OH, CoCr-OH-Si45, CoCr-OH-Si45-GO12h, CoCr-OH-Si45-GO24h, CoCr-OH-Si75, CoCr-OH-Si75-GO12h, CoCr-OH-Si75-GO24h. Cada archivo está compuesto por 5 columnas: frecuencia, impedancia real (Z'), impedancia imaginaria (Z''), módulo de impedancia (Z) y ángulo de fase (Fase). Todos los archivos están en extensión abierta como .txt y están protegidos por una licencia Creative Commons Attribution 4.0 International (CC BY 4.0)., [EN] This is the experimental dataset used in the paper “Barrier Graphene Oxide on a CoCr Alloy via Silane/GO Covalent Bonding and Its Electrochemical Behavior in a Simulated Synovial Fluid Electrolyte". The article includes the experimental procedure carried out for the deposition of graphene oxide on CoCr surfaces: CoCr was hydroxylated through alkalization in NaOH 5 M for 2 h, (sample named CoCr-OH). Subsequently, silanization was carried out using APTES. APTES was pre-mixed at 2% vol in isopropanol-water (200:1 v/v) and stirred for 1 h. After this, CoCr-OH samples were immersed in the APTES solution at room temperature for 1 min. The silane-coated samples were kept under curing conditions at 45 °C (CoCr-OH-Si45 sample) and 75 °C (CoCr-OH-Si75 sample) for 24 h and 30 min, respectively. Finally, CoCr-OH-Si45 and CoCr-OH-Si75 surfaces were immersed in 4 g/L GO aqueous suspension at 60 °C for 12 h and 24 h to obtain CoCr-OH-Si45-GO12h, CoCr-OH-Si75-GO12h and CoCr-OH-Si45-GO24h, and CoCr-OH-Si75-GO24h. This data set includes the results of the electrochemical impedance data obtained for each CoCr surface: CoCr (CoCr, CoCr-OH, CoCr-OHSi45, CoCr-OH-Si75 CoCr-OH-Si45-GO12h, CoCr-OH-Si75-GO12h y CoCr-OH-Si45-GO24h, y CoCr-OH-Si75-GO24h, immersed in 3 g/L Hyaluronic acid solution for 7 days., [ES] Este es el conjunto de datos experimentales utilizado en el artículo "Barrera de Óxido de Grafeno en una Aleación CoCr mediante enlace covalente de Silano/GO y su comportamiento electroquímico en un electrolito de fluido sinovial simulado". El artículo incluye el procedimiento experimental llevado a cabo para la deposición de óxido de grafeno sobre superficies de CoCr: CoCr fue hidroxilado mediante alcalinización en NaOH 5 M durante 2 horas (muestra denominada CoCr-OH). Posteriormente, se llevó a cabo la silanización utilizando APTES. APTES fue premezclado al 2% en volumen en isopropanol-agua (200:1 v/v) y agitado durante 1 hora. Después, las muestras de CoCr-OH fueron sumergidas en la solución de APTES a temperatura ambiente durante 1 minuto. Las muestras recubiertas con silano se mantuvieron bajo condiciones de curado a 45 °C (muestra CoCr-OH-Si45) y 75 °C (muestra CoCr-OH-Si75) durante 24 horas y 30 minutos, respectivamente. Finalmente, las superficies CoCr-OH-Si45 y CoCr-OH-Si75 fueron sumergidas en suspensión acuosa de 4 g/L GO a 60 °C durante 12 y 24 horas obteniendo las superficies CoCr-OH-Si45-GO12h, CoCr-OH-Si75-GO12h y CoCr-OH-Si45-GO24h, y CoCr-OH-Si75-GO24h. Este conjunto de datos incluye los resultados de los datos de impedancia electroquímica obtenidos para cada superficie de CoCr (CoCr, CoCr-OH, CoCr-OHSi45, CoCr-OH-Si75 CoCr-OH-Si45-GO12h, CoCr-OH-Si75-GO12h y CoCr-OH-Si45-GO24h, y CoCr-OH-Si75-GO24h sumergidas en una solución de 3 g/L ácido hialurónico durante 7 días., We acknowledge financial support from the Spanish Ministerio de Ciencia, Innovación y Univeesidades, “ERDF A way of making Europe” and “ESF Investing in your future” through projects RTI2018-101506-B-C31 and RTI2018-101506-B-C33, and PRE2019-090122., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Raman and EIS Dataset for the paper "Macrophage Proteomic Analysis of Covalent Immobilization of Hyaluronic Acid and Graphene Oxide on CoCr Alloy in a Tribocorrosive Environment"

  • Sánchez-López, Luna
  • Chico, Belén
  • García-Alonso, M. C.
  • Lozano, R.M.
[EN] CoCrGO and CoCrGOHA surfaces were characterized by Raman spectroscopy and electrochemical impedance spectroscopy (EIS). Raman spectra were collected with a Raman spectrometer B&W TEK (BTC675N) using a 532 nm wavelength laser. Exposure time was set at 100 ms per scan. Spectral data were processed using BWSpec4 software with dark-frame substraction. Spectra were collected from 50 cm-1 to 4000 cm-1 with integration times of 100 s for CoCrGO and CoCrGOH surfaces and 300 s for graphene oxide (GO) reference sample and 20 s for hyaluronic acid (HA) reference sample. EIS data for CoCrGOHA surfaces were recorded up to 23 days of immersion in 3 g/L HA aqueous electrolyte. A three-electrode electrochemical cell consisting of CoCrGO or CoCrGOHA surfaces as working electrodes, a Pt wire as counter electrode and Ag/AgCl (3 M KCl) as reference electrode were used. The testing area of the working electrode for all electrochemical tests was 0.39 cm2. An Autolab32 potentiostat/galvanostat was used to generate a sinusoidal wave of 10 mV amplitude applied at the corrosion potential Ecorr in the 100 kHz- 1 mHz frequency range logarithmically spaced by 5 points/decade. Nova software was used for the data acquisition. All the tests were performed in duplicate. The dataset includes only the experimental data used in the paper. The following folders are included: RamanCoCrGO+CoCrGOHA and EISCoCrGO+CoCrGOHA. Inside Raman spectra folder, Raman files corresponding to CoCrGO and CoCrGOHA surfaces and GO and HA as reference are added. Each Raman file is composed of 8 columns, corresponding to pixel, wavelength, wavenumber, Ramanshift, Reference, Rawdata and Dark substracted. Each file of EIS data is composed of 5 columns: frequency, real impedance (Z’), imaginary impedance (imag Z), Impedance modulus (Z) and phase angle (Phase). All files are in open extension such as .txt and are protected by a Creative Commons Attribution 4.0 International (CC BY 4.0) licence. [ES] Las superficies de CoCrGO y CoCrGOHA fueron caracterizadas mediante espectroscopía Raman y espectroscopía de impedancia electroquímica (EIS). Los espectros Raman fueron recogidos con un espectrómetro Raman B&W TEK (BTC675N) utilizando un láser de longitud de onda de 532 nm. El tiempo de exposición se estableció en 100 ms para cada barrido. Los datos espectrales fueron procesados utilizando el software BWSpec4 con substracción de marco oscuro. Los espectros fueron registrados desde 50 cm-1 hasta 4000 cm-1 con tiempos de integración de 100 s para las superficies de CoCrGO y CoCrGOHA, y de 300 s para la muestra de referencia de GO y de 20 s para la muestra referencia de ácido hialurónico (HA). Los datos de EIS para las superficies CoCrGOHA fueron registrados hasta 23 días de inmersión en electrolito acuoso de 3 g/L HA. Se utilizó una celda electroquímica de tres electrodos consistente en las superficies CoCrGO o CoCrGOHA como electrodos de trabajo, un alambre de Pt como electrodo auxiliar y Ag/AgCl (3 M KCl) como electrodo de referencia. El área de ensayo del electrodo de trabajo para todas las pruebas electroquímicas fue de 0.39 cm2. Se utilizó un potenciostato/galvanostato Autolab32 para generar una onda sinusoidal de amplitud de 10 mV aplicada sobre el potencial de corrosión Ecorr en el rango de frecuencia de 100 kHz a 1 mHz espaciado logarítmicamente 5 puntos/década. Se utilizó el software Nova para la adquisición de datos. Todas las pruebas se realizaron por duplicado. El conjunto de datos incluye únicamente los datos experimentales utilizados en el artículo. Las siguientes carpetas están incluidas: RamanCoCrGO+CoCrGOHA y EISCoCrGO+CoCrGOHA. Dentro de la carpeta de espectros Raman, se agregan archivos Raman correspondientes a las superficies CoCrGO y CoCrGOHA, y las referencias de GO y HA. Dentro de la carpeta de impedancia (EIS) se han añadido los archivos de las superficies de CoCrGO y CoCrGOHA. Cada archivo Raman está compuesto por 8 columnas, correspondientes a píxel, longitud de onda, número de onda, desplazamiento Raman, referencia, datos en crudo y sustracción de fondo. Cada archivo de EIS está compuesto por 5 columnas: frecuencia, impedancia real (Z’), impedancia imaginaria (imag Z), módulo de impedancia (Z) y ángulo de fase (Fase). Todos los archivos están en formato de texto (.txt) y están protegidos por una licencia Creative Commons Attribution 4.0 International (CC BY 4.0)., [EN] This is the experimental dataset used in the paper “Macrophage Proteomic Analysis of Covalent Immobilization of Hyaluronic Acid and Graphene Oxide on CoCr Alloy in a Tribocorrosive Environment". The article includes the experimental procedure carried out for the deposition of graphene oxide and posterior immobilization of hyaluronic acid on CoCr surfaces. CoCr was hydroxylated through alkalization in NaOH 5 M for 2 h. Subsequently, silanization was carried out using APTES. APTES was pre-mixed at 2% vol in isopropanol-water (200:1 v/v) and stirred for 1 h. After this, CoCr-OH samples were immersed in the APTES solution at room temperature for 1 min. The silane-coated samples were kept under curing conditions at 45 °C for 24 h. Then, silanized CoCr surfaces were immersed in 4 g/L GO aqueous suspension at 60 °C for 24 h. Carboxylic groups of graphene oxide in GO/CoCr samples were activated by immersing in distilled water (50 mL) with N-(3-dimethylaminopropyl)-N-ethylcarbodiimide hydrochloride (EDC, 250 mg) and N-hydroxysuccinimide (NHS, 750 mg) during 24 h under mild orbital saking. After that, the GO/CoCr surfaces with activated carboxyl groups were immersed in distilled water (100 mL) with dissolved adipic dihydrazide (ADH, 1.04 g) and let to react for another 24 h under mild orbital shaking. Pre-activated HA-(EDC/NHS) solution was obtained by dissolving HA (100 mg), EDC (253 mg) and NHS (754 mg) in 100 mL phosphate buffer saline (PBS) and stirred for 24h to activate the carboxylic acids of HA. After that, ADH/GO/CoCr surfaces were immersed in pre-activated HA-(EDC/NHS) solution and let to react for 24h under mild orbital motion (samples named HA/GO/CoCr). This data set includes the results of the final surface by Raman Spectroscopy and Electrochemical Impedance Spectroscopy. Raman was obtained from CoCr/GO/HA surfaces in comparison with GO/CoCr surfaces and HA powder. Electrochemical impedance data of CoCr/GO/HA were obtained under immersion in 3 g/L Hyaluronic acid solution up to 23 days., [ES] Este es el conjunto de datos experimentales utilizado en el artículo " Macrophage Proteomic Analysis of Covalent Immobilization of Hyaluronic Acid and Graphene Oxide on CoCr Alloy in a Tribocorrosive Environment". El artículo incluye el procedimiento experimental realizado para la deposición de óxido de grafeno y la posterior inmovilización de ácido hialurónico sobre superficies de CoCr. Las superficies de CoCr fueron hidroxiladas mediante alcalinización en NaOH 5 M durante 2 h. Posteriormente, se realizó la silanización utilizando APTES premezclado al 2% en volumen en isopropanol-agua (200:1 v/v) agitada durante 1 h. Las muestras de CoCr hidroxiladas se sumergieron en la solución de APTES a temperatura ambiente durante 1 minuto. Posteriormente, se mantuvieron en condiciones de curado a 45 °C durante 24 h. Transcurrido este tiempo, las superficies de CoCr silanizadas se sumergieron en una suspensión acuosa de 4g/L GO a 60 °C durante 24 h. Los grupos carboxílicos del óxido de grafeno en las muestras GO/CoCr se activaron mediante inmersión en 50 mL agua destilada que contenía hidrocloruro de N-(3-dimetilaminopropil)-N-etilcarbodiimida (EDC, 250 mg) y N-hidroxisuccinimida (NHS, 750 mg), durante 24 h en agitación orbital suave. Las superficies de GO/CoCr con grupos carboxílicos activados se sumergieron en 100 mL de agua destilada con dihidracida adipídica disuelta (ADH, 1.04 g) y se dejaron reaccionar durante otras 24 h en agitación orbital suave. La solución de HA preactivada (EDC/NHS) se obtuvo disolviendo HA (100 mg), EDC (253 mg) y NHS (754 mg) en 100 mL de solución salina de fosfato (PBS) y agitando durante 24 h para activar los ácidos carboxílicos de la HA. Después, las superficies de ADH/GO/CoCr se sumergieron en la solución de HA preactivada (EDC/NHS) y se dejaron reaccionar durante 24 h en movimiento orbital suave (muestras denominadas HA/GO/CoCr). Este conjunto de datos incluye los resultados de la caracterización superficial final mediante espectroscopía Raman y espectroscopia de impedancia electroquímica. Se obtuvieron espectros Raman de superficies de HA/GO/CoCr, GO/CoCr, y se compararon con GO y ácido hialurónico, utilizados como referencia. Los datos de impedancia electroquímica de CoCr/GO/HA se obtuvieron en inmersión en solución de 3 g/L ácido hialurónico hasta 23 días., We acknowledge financial support from the Ministerio de Ciencia, Innovación y Universidades (MICIN), "ERDF A way of making Europe” and “ESF Investing in your future" through projects RTI2018-101506-B-C31 and RTI2018-101506-B-C31 and the predoctoral grant PRE2019-090122., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Dataset collection of proteomic data for the paper "Effect of wear-corrosion of CoCr functionalized with reduced graphene oxide and hyaluronic acid on the proteomic response of J774A.1 macrophages"

  • Sánchez-López, Luna
  • Ropero de Torres, Noelia
  • Chico, Belén
  • Fagali, Natalia Soledad
  • Ríos, Vivian de los
  • Escudero, María Lorenza
  • García-Alonso, M. C.
  • Lozano, R.M.
The presence of a worn surface in the implanted material, as in the case of a replacement of a damaged osteoarticular joint, is the normal condition after implantation. This manuscript focuses precisely on the comparative study of the cellular behavior on worn CoCr surfaces, analyzing the effect of different surface modifications on macrophages’ responses. CoCr surfaces were modified by the deposition of electrochemically reduced graphene oxide (CoCrErGO), followed by additional surface functionalization with hyaluronic acid (CoCrErGOHA). After the wear corrosion processes, the macrophage response was studied. In addition, macrophage supernatants exposed to the surfaces, before and after wear, were also evaluated for osteoblast response through the analysis of the metabolic activity, plasma membrane damage, and phosphatase alkaline activity (ALP). The proteomic analysis and the quantitative TNF- /IL-10 ratios of the J774A.1 macrophages exposed to the surfaces under study showed a polarization shift from M0 (basal state) to M1, associated with the pro-inflammatory response of all surfaces. A lower M1 polarization was observed upon exposure to the surface modification with ErGO, whereas posterior HA functionalization attenuated, even more, the M1 polarization. The wear corrosion process contributed to inflammation and exacerbated the M1 polarization response on macrophages to CoCr, which was diminished for the ErGO and attenuated the most for the ErGOHA surfaces. Comparative proteomics showed that the pathways related to M1 polarization were downregulated on the surfaces of CoCrErGOHA, which suggests mechanisms for the observed attenuation of M1 polarization. The suitable immuno-modulatory potential induced by the ErGOHA surface, with and without wear, together with the stimulation of ALP activity in osteoblasts induced by macrophage supernatants, promotes the mineralization processes necessary for bone repair. This makes it feasible to consider the adsorption of ErGOHA on CoCr as a recommended surface treatment for the use of biomaterials in osseous joint applications., RTI2018-101506-B-C31 and RTI2018-101506-B-C33 from the Ministerio de Ciencia, Innovación y Universidades (MICIU/FEDER) in Spain. MICIU for the predoctoral contract PRE2019-090122., Proteome Dataset: Effect of wear-corrosion of CoCr functionalized with reduced graphene oxide and hyaluronic acid on the proteomic response of J774A.1 Macrophages, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Dataset for the paper "Hematological response to particle debris generated during wear–corrosion processes of CoCr surfaces modified with gra-phene oxide and hyaluronic acid for joint prostheses"

  • Escudero Rincón, , María Lorenza
  • García-Alonso, M. C.
  • Chico, Belén
  • Lozano, Rosa María
  • Sánchez-López, Luna
  • Flores-Sáenz, Manuel
  • Cristóbal-Aguado, Soledad
  • Moreno-Gómez-Toledano, Rafael
  • Aguado-Henche, Soledad
The dataset includes data on particle characterization of debris collected from wear-corrosion tests and blood analysis from rats after 30 days of inoculation. Particle size distribution of the debris was measured using a MasterSizer 3000 with laser diffraction technology. This device features a red He-Ne laser (wavelength: 632.8 nm), a blue LED laser (wavelength: 470 nm), and a Hydro SV small volume dispersion unit with stirring. Measurements were taken with laser obscuration set between 3% and 15%, and sample dispersion was achieved at 1200 rpm. Two debris samples were analyzed, each with three measurements. The dataset contains six files, each with two columns labeled "size" and "volume."Blood analysis was conducted prior to euthanizing the animals in a CO2 chamber, with 1.5 mL of intracardiac blood extracted. Serum samples were prepared by centrifugation at 3,000 x g for 15 minutes, then separated and stored in 1.5 mL Eppendorf tubes in a cold chamber for transport to a laboratory. Hematological analysis was performed by UNILABS (Madrid, Spain) using a Sysmex Kx-21n hematology autoanalyzer (Sysmex Corporation, Kobe, Japan). The dataset file consists of 21 columns, detailing results by treatment group (Serum control, Hyaluronic acid, and Graphene) and particle concentrations (0.63 mg/ml, 1.83 mg/ml, 1.65 mg/ml, and 2.35 mg/ml). Hematological parameters in the dataset include hemoglobin (Hgb), hematocrit (Hct), white blood cell (WBC) count, red blood cell (RBC) count, mean corpuscular volume (MCV), mean corpuscular hemoglobin concentration (MCHC), and platelet (PLT) count. Biochemical parameters measured in serum samples are creatinine (Crea), aspartate aminotransferase (AST), alanine aminotransferase (ALT), lactate dehydrogenase (LDH), total protein (TP), triglycerides (TG), and cholesterol (CHO). Coagulation parameters include prothrombin time (PT), thromboplastin time (TT), and fibrinogen (F)., [EN] This is the experimental dataset used in the paper "Hematological response to particle debris generated during wear–corrosion processes of CoCr surfaces modified with graphene oxide and hyaluronic acid for joint prostheses". The paper includes the results of the potential biological responses and consequences of wear-corrosion processes associated with CoCr surfaces modified with graphene oxide and hyaluronic acid (CoCr-GO-HA), through in vitro (macrophage cultures) and in vivo (rat models) assays. Once the graphene oxide functionalized with hyaluronic acid was deposited on CoCr surfaces, wear-corrosion tests were performed by applying a 5N load at a rotational speed of 120 rpm over 30,000 m (682,000 cycles) in an aqueous solution of 3 g/L hyaluronic acid (HA), continuously recirculated during the experiment. The generated particles were collected and redispersed in 0.9% NaCl at concentrations of 0.63 mg/mL, 1.65 mg/mL, 1.83 mg/mL, and 2.35 mg/mL. The particles were intra-articularly injected into the knees of rats. This dataset includes the results of the wear particle characterization and the hematological analysis and biochemical parameters, 30 days after intra-articular knee injection in rats. Whole-blood hematological parameters included hemoglobin (Hgb), hematocrit (Hct), white blood cell (WBC) count, red blood cell (RBC) count, mean corpuscular volume (MCV), mean corpuscular hemoglobin concentration (MCHC), and platelet (PLT) count., [ES] Este es el conjunto de datos experimentales utilizado en el artículo "Respuesta hematológica a los desechos de partículas generados durante los procesos de desgaste-corrosión de superficies de CoCr modificadas con óxido de grafeno y ácido hialurónico para prótesis articulares". El artículo incluye los resultados de las posibles respuestas biológicas y consecuencias de los procesos de desgaste-corrosión asociados con superficies de CoCr modificadas con óxido de grafeno y ácido hialurónico (CoCr-GO-HA), mediante ensayos in vitro (cultivos de macrófagos) e in vivo (modelos de ratas). Una vez depositado el óxido de grafeno funcionalizado con ácido hialurónico sobre superficies de CoCr, se realizaron ensayos de desgaste-corrosión aplicando una carga de 5N a una velocidad de rotación de 120 rpm durante 30,000 m (682,000 ciclos) en una solución acuosa 3 g/L de ácido hialurónico (HA), recirculada continuamente durante el experimento. Las partículas generadas se recogieron y se redispersaron en NaCl al 0.9%, a concentraciones de 0.63 mg/mL, 1.65 mg/mL, 1.83 mg/mL y 2.35 mg/mL. Las partículas fueron inyectadas intra-articularmente en rodilla de ratas. Este conjunto de datos incluye los resultados de la caracterización de partículas generadas durante los experimentos de desgaste-corrosión y los análisis hematológicos y parámetros bioquímicos después de 30 días de la inyección intraarticular en las rodillas de las ratas. Los parámetros hematológicos de sangre completa incluyeron hemoglobina (Hgb), hematocrito (Hct), conteo de glóbulos blancos (WBC), conteo de glóbulos rojos (RBC), volumen corpuscular medio (MCV), concentración media de hemoglobina corpuscular (MCHC) y conteo de plaquetas (PLT)., Ministerio de Ciencia e Innovación (MCIN), No