Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 1
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Effect of feature extraction for brain tumor classification based on short echo time 1H MR spectra

  • Luts, Jan
  • Poullet, Jean-Baptiste
  • Heerschap, Arend
  • Robles, Montserrat
  • Suykens, Johan A.K.
  • Van Huffel, Sabine
  • Garcia-Gomez, Juan M
[EN] This study examines the effect of feature extraction methods prior to automated pattern recognition based on magnetic resonance spectroscopy (MRS) for brain tumor diagnosis. Since individual inspection of spectra is time-consuming and requires specific spectroscopic expertise, the introduction of clinical decision support systems.(DSSs) is expected to strongly promote the clinical use of MRS. This study focuses on the feature extraction step in the preprocessing protocol of MRS when using a DSS. On two independent data sets, encompassing single-voxel and multi-voxel data, it is observed that the use of the full spectra together with a kernel-based technique, handling high dimensional data, or using an automated pattern recognition method based on independent component analysis or Relief-F achieves accurate performances. In addition, these approaches have low cost and are easy to automate. When sophisticated quantification methods are used in a DSS, user interaction should be minimized. The computationally intensive quantification techniques do not tend to increase the performance in these circumstances. The results suggest to simplify the feature reduction step in the preprocessing protocol when using a DSS purely for classification purposes. This can greatly speed up the execution of classifiers and DSSs and may accelerate their introduction into clinical practice., The authors thank the Institute for Molecules and Materials, Analytical Chemistry, Chemometrics Research Department of the Radboud University Nijmegen for preprocessing the MRSI data. Margarida Julia-Sape is gratefully acknowledged for all data management tasks; the clinical partners represented by Dr. Witold Gajewicz (MUL, Lodzi, Poland) and Jorge Andres Calvar (FLENI, Ciudad de Buenos Aires, Argentina) are gratefully acknowledged for providing data. Grant sponsors: Institute for the Promotion of Innovation through Science and Technology in Flanders (IWT-Vlaanderen), Research Council KUL: GOA-AMBioRICS, Centers-of-Excellence in Optimisation; Grant sponsor: IDO; Grant number: 05/010 EEG-fMRI; Grant sponsor: Flemish Government: FWO; Grant numbers: G.0360.05, G.0519.06, G.0341.07, G.0321.06, G.0302.07; Grant sponsors: ICCoS, ANMMM, IWT; Grant sponsor: Belgian Federal Government: DWTC; Grant numbers: IUAP IV-02 (1996 2001), IUAP V-22 (2002 2006);Grant sponsor: Belgian Federal Science Policy Office;Grant number: IUAP P6/04; Grant sponsor: EU; Grant number: IST-1999-10310; Grant sponsor: BIOPATTERN; Grant number: FP6-2002-IST 508803; Grant sponsor: eTUMOUR; Grant number: FP6-2002-LIFESCIHEALTH 503094; Grant sponsor: HealthAgents; Grant number: FP6-2005-IST 027213; Grant sponsor: FAST; Grant number: FP6-019279-2; Grant sponsor: ESA: Cardiovascular Control; Grant number: Prodex-8 C90242.