Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

On the rejection and reversibility of fouling in ultrafiltration as assessed by hydraulic impedance spectroscopy

  • Martí Calatayud, Manuel César|||0000-0002-0745-1918
  • Schneider, S.
  • Wessling, Matthias
[EN] The manifestation of critical fluxes in membrane filtration has typically served to set an upper value above which detrimental fouling events and a substantial increase of membrane resistance occurs. Despite the usefulness of critical flux concepts for conducting sustainable membrane processes, the specific phenomena causing them cannot be easily identified via conventional membrane filtration modes. Usually arbitrary fouling rates are selected to delimit the boundary between under- and over-critical flux operation. Timescales respective for colloidal matter accumulation are overlooked. Frequency response analysis of transmembrane pressures has been recently presented as a highly-sensitive method to track fouling in ultrafiltration. This hydraulic impedance spectroscopy method allows not only measuring membrane resistances but also corresponding time constants related to colloidal matter accumulation. In this work, hydraulic impedance spectra are gained for the ultrafiltration of different model foulants to assess the origin of critical fluxes for two different membranes. A correlation among characteristic impedance features and the type of fouling could be established: the evolution of phase shift between flux and pressure at increasing fluxes allows identifying the formation of external fouling layers, while registering of hysteresis loops at reversed frequency sequences signals the development of irreversible internal fouling. The hydraulic impedance method emerges as a precise and more sensitive monitoring tool to diagnose the beginning and nature of critical fouling., M.W. acknowledges the support through an Alexander-von-Humboldt Professorship. M.C. Marti-Calatayud is grateful for the funding received from the Generalitat Valenciana (APOSTD/2017/059). M.C. Marti-Calatayud also appreciates the helpful suggestions received by Tao Luo and Georg Linz, as well as the fruitful discussions with Sarah Armbruster. This work was supported by the German Federal Ministry of Education and Research (BMBF) through the project BRAMAR (02WCL1334A). We thank Synder Filtration for the supplied membranes.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Interplay between physical cleaning, membrane pore size and fluid rheology during the evolution of fouling in membrane bioreactors

  • Martí Calatayud, Manuel César|||0000-0002-0745-1918
  • Schneider, S.
  • Yüce, S.
  • Wessling, M.
[EN] Fouling is one of the most pressing limitations during operation of membrane bioreactors, as it increases operating costs and is the cause of short membrane lifespans. Conducting effective physical cleanings is thus essential for keeping membrane operation above viable performance limits. The nature of organic foulants present in the sludge and the membrane properties are among the most influential factors determining fouling development and thus, efficiency of fouling mitigation approaches. The role of other factors like sludge viscosity on fouling is still unclear, given that contradictory effects have been reported in the literature. In the present study we use a new research approach by which the complex interplay between fouling type, levels of permeate flux, membrane material and feed properties is analyzed, and the influence of these factors on critical flux and membrane permeability is evaluated. A variety of systems including activated sludge and model solutions with distinct rheological behavior has been investigated for two membranes differing in pore size distribution. We present a novel method for assessing the efficiency of fouling removal by backwash and compare it with the efficiency achieved by means of relaxation. Results obtained have proven that backwash delays development of critical fouling as compared with relaxation and reduces fouling irreversibility regardless of fluid rheology. It was shown that backwash is especially effective for membranes for which internal fouling is the main cause of loss in permeability. Nonetheless, we found out that for membranes with tight pores, both relaxation and backwash are equally effective. The critical flux decreases significantly for high-viscosity fluids, such as activated sludge. This effect is mainly caused by an intensified concentration polarization at the feed side rather than by internal fouling events. However, membrane permeability has been proven to rely more on the permeate viscosity than on the feed viscosity: poor rejection of organic fractions showcasing high viscosity causes an acute decline in membrane permeability as a consequence of increased shear stress inside the membrane pores. (C) 2018 Elsevier Ltd. All rights reserved., M.W. acknowledges the support through an Alexander-von-Humboldt Professorship. M.C. Marti-Calatayud acknowledges the support to Generalitat Valenciana through the funding APOSTD2017. M.C. Marti-Calatayud thanks the contributions of Sybille Hanisch, Sanchita Khandelwal and Sara Vivanco. This work was supported by the German Federal Ministry of Education and Research (BMBF) through the project BRAMAR (02WCL1334A). We thank Synder Filtration for the supplied membranes
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Transients of micropollutant removal from high-strength wastewaters in PAC-assisted MBR and MBR coupled with high-retention membranes

  • Martí Calatayud, Manuel César|||0000-0002-0745-1918
  • Hessler, R.
  • Schneider, S.
  • Bohner, C.
  • Yüce, S.
  • Wessling, M.
  • de Sena, R.F.
  • Athayde Júnior, G.B.
[EN] Removal of micropollutants from wastewaters is crucial to ensure safe water reuse and protect natural water-courses. Although membrane bioreactors (MBRs) yield improved degradation of organic compounds, hydraulic retention times are often too short to satisfy acceptable removal rates of recalcitrant organics. Often, results regarding micropollutant removal in treatment plants are susceptible to uncontrolled feed concentrations, which are concomitant to seasonality and consumer habits. In this work, we investigate the concentration transients of four selected pesticides (carbendazim, diuron, 2,4-D and atrazine), which were constantly dosed to a MBR pilot plant treating high-strength industrial effluents (COD values ). In addition to the regular MBR operation, two feasible means of extending pesticide retention in bioreactors were evaluated: (i) addition of small concentrations of powdered activated carbon (PAC) into the activated sludge and (ii) coupling of the PAC-assisted MBR and a reverse osmosis unit (RO) with recirculation of the retentate. The aim of this work is to provide reliable information on the fate of micropollutants within wastewater treatment plants using different configurations under controlled feed conditions. Results have shown that carbendazim was the only pesticide efficiently (>80%) removed during regular MBR operation, which has been attributed to the presence of electron donating groups attached to its aromatic ring structure. Improved retention of diuron by addition of PAC enhanced its long-term removal, whereas the effect of PAC addition on the removal of 2,4-D and atrazine was only temporary, thus being mainly attributed to an adsorption effect. Additionally, the function of PAC as platform for biofloc formation limited sludge production and slowed down membrane fouling, further improving the general performance of the MBR. The MBR-RO hybrid process was the most effective one in increasing the residence time of pesticides in the bioreactor, regardless of their functional groups and properties, thus facilitating a generalized removal of micropollutants., M.W. acknowledges the support through an Alexander-von-Humboldt Professorship. M.C. Marti-Calatayud acknowledges the support to Generalitat Valenciana through the funding APOSTD2017. This work was supported by the German Federal Ministry of Education and Research (BMBF) through the project BRAMAR (02WCL1334A). The authors thank the company Intrafrut S.A., Almir Gomes da Costa, Lisa Awater, Thiago Santos, Carlos Pereira and Sybille Hanisch for their cooperation.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Membrane bioreactor applied to the treatment of a fruit processing industry wastewater in Northeast Brazil

  • Pereira de Morais, Carlos Eduardo
  • Awater, Lisa Christina
  • Athayde Júnior, Gilson Barbosa
  • de Sena, Rennio Félix
  • Bohner, Christoph
  • Martí Calatayud, Manuel César|||0000-0002-0745-1918
[EN] The market for Membrane Bioreactors (MBR) technology has recently grown due to increasingly strict standards for effluent discharge and the need for alternative water sources. The high quality of the effluent produced, enabling the possibility of reuse is one of the most attractive characteristics of this technology. The objective of this article was to evaluate the treatment efficiency of a pilot-scale MBR plant in a fruit processing industry, including an analysis of the possibilities for effluent reuse. The pilot plant comprised a MBR with approximately 5000L in capacity, with porous type ultrafiltration grade polyethersulfone membranes. Other details for the membranes were: submerged configuration, flat plate type geometry, pore diameter ranging from 0.035 to 0.1 ¿m and total area of 25m². The industrial effluent came from fruits processing, floors and machinery washing, and was characterized by physical, chemical and bacteriological parameters. Results showed that permeability decreased about 50% during the monitoring, indicating the need of membrane cleaning. The removal efficiency for COD, BOD5, total nitrogen and total phosphorus, was 97.1%, 98.7%; 95.7 % and 53.5%, respectively. There was an absence of both total coliform and E. Coli at the inlet and outlet of the system. The permeate fits into agricultural, urban, environmental, industrial and aquaculture reuse modalities., This article is part of a master dissertation presented at the Postgraduate Program of Civil and Environmental Engineering of Federal University of Paraíba (Brazil) ¿ PPGECAM/UFPB. Acknowledgments are also due to CNPq (scholarship), FINEP and BMBF for research funding (BRAMAR Project). We also acknowledge the Brazilian National Council for Scientific and Technological Development - CNPq (through funding process 423869/2016-7 - Project Universal) for finantial support.