Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Electrical Stimulation of Cells: Drivers, Technology, and Effects

  • Kadan-Jamal, Kian
  • Wronowski, Filip
  • Jin, Amy
  • Naegele, Tobias E.
  • Rincón Montes, Viviana
  • Tao, Xudong
  • DomÍnguez Alfaro, Antonio
  • Lee, Chaeyeon
  • Malliaras, George G.
Published as part of Chemical Reviews special issue “Electric Fields in Chemistry and Biology”, Exposure of cells to electric fields is used in applications as diverse as deep brain stimulation to treat the symptoms of Parkinson's disease, tumor-treating fields to delay the progression of hard-to-treat cancers, and electroporation to deliver genetic materials to cells. It is also used to study the fundamental properties of electrically active cells and to induce changes in cell behavior, such as the directed outgrowth of neurites, that may one day find applications in the clinic. This review discusses some of the effects elicited on cells upon exposure to electric fields, both acutely and at longer time scales, and considers the underlying mechanisms proposed. It also provides an overview of the technology used to study the effects of exposure of cell to electric fields, including the different types of metal/electrolyte interfaces and the electrode materials used in in vitro and in vivo applications. The aim is to bring together concepts from different communities to highlight similarities, identify potential synergies, and create common ground that may lead to cross-fertilization and advances in the field., The authors acknowledge funding from EPSRC (IRC in Targeted Delivery for Hard-to-Treat Cancers EP/S009000/1 and program grant EP/W017091/1), a Horizon Europe UKRI underwrite Innovate grant (COPE-Nano, 10078978), and the NIHR Cambridge Biomedical Research Centre (NIHR203312). KKJ gratefully acknowledges support from the Presidential Scholarship for Postdoctoral studies for women (Tel Aviv University) and the Blavatnik Cambridge Postdoctoral Fellowship. The views expressed are those of the authors and not necessarily those of the NIHR or the Department of Health and Social Care. For the purpose of open access, the author has applied a Creative Commons Attribution (CC BY) licence to any Author Accepted Manuscript version arising., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

PEDOT:PSS conducting eutectogel for enhanced electrical recording and stimulation in implantable neural interfaces

  • Kasavetov, Martin
  • Ruiz-Mateos Serrano, Rubén
  • Domínguez Alfaro, Antonio
  • Lee, Chaeyeon
  • Picchio, Matias L.
  • Mecerreyes, David
  • Malliaras, George G.
  • Rincón Montes, Viviana
  • Güemes, Amparo
Conductive polymers such as PEDOT:PSS are widely used in bioelectronic interfaces due to their mixed ionic–electronic conductivity and biocompatibility. However, their mechanical fragility and limited processability constrain their performance in implantable devices. Deep eutectic solvents (DES), when combined with PEDOT:PSS, form eutectogels that enable thick, soft coatings. Here, we present a PEDOT:PSS-based eutectogel incorporating choline chloride, lactic acid and GOPS, integrated into flexible thin-film electrode arrays for sciatic nerve interfacing. These implants feature an array of electrodes and a pre-formed spiral geometry to conformally wrap small-diameter nerves. Devices were fabricated using standard photolithography and reactive ion etching techniques, allowing side-by-side comparison of PEDOT:PSS/DES with conventional PEDOT:PSS electrodes. PEDOT:PSS/DES enabled single-layer films up to 800 nm thick, significantly greater than PEDOT:PSS, and yielding over three-fold improvements in impedance and charge injection capacity in vitro. Acute in vivo electrophysiology in rats confirmed enhanced neural recording and stimulation capabilities, with lower impedance, higher capacitance, and reduced motor activation thresholds. While PEDOT:PSS/DES more reliably elicited motor responses at lower stimulation currents, electromyogram signal amplitudes from the tibialis anterioris at matched stimulation levels were comparable between materials. These results suggest that while superior electrochemical properties improve neural interface performance, local electrode–tissue interactions remain critical. Overall, this work establishes DES-modified PEDOT:PSS as a promising electrode material for soft neural interfaces and highlights its potential for advancing implantable bioelectronics., The authors thank the Helmholtz Nano Facility (HNF) at Forschungszentrum Jülich for facilitating the microfabrication and S. Decke, E. Yilmaz, and R. Stockmann for providing support during microfabrication. The authors also thank E. Brauweiler-Reuters for carrying out FIB sectioning and SEM. The authors thank A. Offenhäusser for infrastructural and scientific support. R. R. M. acknowledges support from EPSRC grant [EP/S022139/1]. G. G. M. and A. D. A. acknowledge support from Horizon Europe UKRI Underwrite Innovate grant COPE-Nano under project number 10078978. M. L. P. and D. M. gratefully acknowledge the financial support from IKERBASQUE-Basque Foundation for Science and the Marie Sklodowska-Curie Research and Innovation Staff Exchanges program under grant agreement IONBIKE 2.0 MSCA-SE 101129945. A. G. acknowledges support from the Royal Academy of Engineering and Rosetrees Trust through grant no. RF-2324-23-284. This work was funded by UKRI grants and was supported by the Deutsche Forschungsgemeinschaft (DFG, German Research Foundation; GRK2610 (project number 424556709)). For the purpose of open access, the author has applied a Creative Commons Attribution (CC BY) licence to any Author Accepted Manuscript version arising., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Body surface potential mapping of the cortico-muscular axis using smart textile electrode arrays

  • Ruiz-Mateos Serrano, Rubén
  • Brunt, Charlie
  • Tao, Xudong
  • Zajaczkowski, Maciej
  • Domínguez Alfaro, Antonio
  • Picchio, Matias L.
  • Mantione, Daniele
  • Drakakis, Emmanuel M.
  • Mecerreyes, David
  • Malliaras, George G.
Cutaneous electrophysiology is a fundamental non-invasive technique for assessing electrically active organs such as the brain, heart, and muscles. Standard approaches, however, are limited in spatial resolution, reducing sensitivity to certain pathological features. The development of body surface potential mapping using electrode arrays has helped overcome these limitations, enhancing the diagnostic power of cutaneous recordings, yet clinical adoption remains constrained by challenges in electrode performance, wiring complexity, wearability, data transmission, and interpretability. Here, we present a hybrid e-textile electrode array system that overcomes these barriers, enabling simultaneous mapping of electrical activity along the cortico-muscular axis. The system combines application-specific conducting polymer coatings to improve electrode performance, a flexible fabrication process for robust connectivity and wearability, and interpretable machine learning algorithms for data analysis. In controlled single-subject experiments, we demonstrate reliable muscle and brain recordings, enabling classification of grasped object shapes and somatosensory stimuli. Simultaneous multi-site recordings along the cortico-muscular axis provide spatial maps of reaction time distributions and allow prediction of muscle activation patterns from cortical activity. This platform establishes a framework for wearable, multi-modal electrophysiological mapping and non-invasive study of cortico-muscular dynamics, representing a step towards practical brain–body interfaces with applications in neurorehabilitation, prosthetics, and human–machine interaction., This work was supported by EPSRC [grants EP/S022139/1 and EP/W017091/1]. M.L.P. is thankful to the IKERBASQUE-Basque Foundation for Science and the Spanish Research Agency (AEI) (RYC2024-048187-I from RyC program) for the financial support. M.L.P. gratefully acknowledges the financial support from the Basque Government, Department of Education (IT1766-22). Part of this work was funded by the European Union under the IONBIKE 2.0 project (Grant agreement No. 101129945, https://doi.org/10.3030/101129945). The authors acknowledge support from a HORIZON EUROPE UKRI UNDERWRITE INNOVATE grant (COPE-Nano, 10078978) and from the NIHR Cambridge Biomedical Research Centre (NIHR203312). The views expressed are those of the authors and not necessarily those of the NIHR or the Department of Health and Social Care. D.M. thanks Ayuda RYC2021-031668-I financed by MCIN/AEI/10.13039/501100011033 and by the European Union NextGenerationEU/PRTR. M.L.P. is thankful to the IKERBASQUE-Basque Foundation for Science, grant RYC2024-048187-I funded by MICIU/AEI/10.13039/501100011033 and FSE+, and the Basque Government, Department of Education (IT1766-22) for the financial support. Partial support by the EPSRC Transformative Healthcare NISNEM Technology Grant (EP/T020970/1) is acknowledged., Peer reviewed