Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 6
Encontrada(s) 1 página(s)

TECNALIA Publications
Publicación Artículo científico (JournalArticle)

Data harmonisation for information fusion in digital healthcare: A state-of-the-art systematic review, meta-analysis and future research directions: A state-of-the-art systematic review, meta-analysis and future research directions

  • Nan, Yang
  • Ser, Javier Del
  • Walsh, Simon
  • Schönlieb, Carola
  • Roberts, Michael
  • Selby, Ian
  • Howard, Kit
  • Owen, John
  • Neville, Jon
  • Guiot, Julien
  • Ernst, Benoit
  • Pastor, Ana
  • Alberich-Bayarri, Angel
  • Menzel, Marion I.
  • Walsh, Sean
  • Vos, Wim
  • Flerin, Nina
  • Charbonnier, Jean-Paul
  • van Rikxoort, Eva
  • Chatterjee, Avishek
  • Woodruff, Henry
  • Lambin, Philippe
  • Cerdá-Alberich, Leonor
  • Martí-Bonmatí, Luis
  • Herrera, Francisco
  • Yang, Guang
Removing the bias and variance of multicentre data has always been a challenge in large scale digital healthcare studies, which requires the ability to integrate clinical features extracted from data acquired by different scanners and protocols to improve stability and robustness. Previous studies have described various computational approaches to fuse single modality multicentre datasets. However, these surveys rarely focused on evaluation metrics and lacked a checklist for computational data harmonisation studies. In this systematic review, we summarise the computational data harmonisation approaches for multi-modality data in the digital healthcare field, including harmonisation strategies and evaluation metrics based on different theories. In addition, a comprehensive checklist that summarises common practices for data harmonisation studies is proposed to guide researchers to report their research findings more effectively. Last but not least, flowcharts presenting possible ways for methodology and metric selection are proposed and the limitations of different methods have been surveyed for future research.
TECNALIA Publications
Publicación Artículo científico (JournalArticle)

AI-based medical e-diagnosis for fast and automatic ventricular volume measurement in patients with normal pressure hydrocephalus

  • Zhou, Xi
  • Ye, Qinghao
  • Yang, Xiaolin
  • Chen, Jiakun
  • Ma, Haiqin
  • Xia, Jun
  • Del Ser, Javier
  • Yang, Guang
Based on CT and MRI images acquired from normal pressure hydrocephalus (NPH) patients, using machine learning methods, we aim to establish a multimodal and high-performance automatic ventricle segmentation method to achieve an efficient and accurate automatic measurement of the ventricular volume. First, we extract the brain CT and MRI images of 143 definite NPH patients. Second, we manually label the ventricular volume (VV) and intracranial volume (ICV). Then, we use the machine learning method to extract features and establish automatic ventricle segmentation model. Finally, we verify the reliability of the model and achieved automatic measurement of VV and ICV. In CT images, the Dice similarity coefficient (DSC), intraclass correlation coefficient (ICC), Pearson correlation, and Bland–Altman analysis of the automatic and manual segmentation result of the VV were 0.95, 0.99, 0.99, and 4.2 ± 2.6, respectively. The results of ICV were 0.96, 0.99, 0.99, and 6.0 ± 3.8, respectively. The whole process takes 3.4 ± 0.3 s. In MRI images, the DSC, ICC, Pearson correlation, and Bland–Altman analysis of the automatic and manual segmentation result of the VV were 0.94, 0.99, 0.99, and 2.0 ± 0.6, respectively. The results of ICV were 0.93, 0.99, 0.99, and 7.9 ± 3.8, respectively. The whole process took 1.9 ± 0.1 s. We have established a multimodal and high-performance automatic ventricle segmentation method to achieve efficient and accurate automatic measurement of the ventricular volume of NPH patients. This can help clinicians quickly and accurately understand the situation of NPH patient’s ventricles.
TECNALIA Publications
Publicación Artículo científico (JournalArticle)

Swin transformer for fast MRI

  • Huang, Jiahao
  • Fang, Yingying
  • Wu, Yinzhe
  • Wu, Huanjun
  • Gao, Zhifan
  • Li, Yang
  • Ser, Javier Del
  • Xia, Jun
  • Yang, Guang
Magnetic resonance imaging (MRI) is an important non-invasive clinical tool that can produce high-resolution and reproducible images. However, a long scanning time is required for high-quality MR images, which leads to exhaustion and discomfort of patients, inducing more artefacts due to voluntary movements of the patients and involuntary physiological movements. To accelerate the scanning process, methods by k-space undersampling and deep learning based reconstruction have been popularised. This work introduced SwinMR, a novel Swin transformer based method for fast MRI reconstruction. The whole network consisted of an input module (IM), a feature extraction module (FEM) and an output module (OM). The IM and OM were 2D convolutional layers and the FEM was composed of a cascaded of residual Swin transformer blocks (RSTBs) and 2D convolutional layers. The RSTB consisted of a series of Swin transformer layers (STLs). The shifted windows multi-head self-attention (W-MSA/SW-MSA) of STL was performed in shifted windows rather than the multi-head self-attention (MSA) of the original transformer in the whole image space. A novel multi-channel loss was proposed by using the sensitivity maps, which was proved to reserve more textures and details. We performed a series of comparative studies and ablation studies in the Calgary-Campinas public brain MR dataset and conducted a downstream segmentation experiment in the Multi-modal Brain Tumour Segmentation Challenge 2017 dataset. The results demonstrate our SwinMR achieved high-quality reconstruction compared with other benchmark methods, and it shows great robustness with different undersampling masks, under noise interruption and on different datasets. The code is publicly available at https://github.com/ayanglab/SwinMR.
TECNALIA Publications
Publicación Artículo científico (JournalArticle)

Edge-enhanced dual discriminator generative adversarial network for fast MRI with parallel imaging using multi-view information

  • Huang, Jiahao
  • Ding, Weiping
  • Lv, Jun
  • Yang, Jingwen
  • Dong, Hao
  • Del Ser, Javier
  • Xia, Jun
  • Ren, Tiaojuan
  • Wong, Stephen T.
  • Yang, Guang
In clinical medicine, magnetic resonance imaging (MRI) is one of the most important tools for diagnosis, triage, prognosis, and treatment planning. However, MRI suffers from an inherent slow data acquisition process because data is collected sequentially in k-space. In recent years, most MRI reconstruction methods proposed in the literature focus on holistic image reconstruction rather than enhancing the edge information. This work steps aside this general trend by elaborating on the enhancement of edge information. Specifically, we introduce a novel parallel imaging coupled dual discriminator generative adversarial network (PIDD-GAN) for fast multi-channel MRI reconstruction by incorporating multi-view information. The dual discriminator design aims to improve the edge information in MRI reconstruction. One discriminator is used for holistic image reconstruction, whereas the other one is responsible for enhancing edge information. An improved U-Net with local and global residual learning is proposed for the generator. Frequency channel attention blocks (FCA Blocks) are embedded in the generator for incorporating attention mechanisms. Content loss is introduced to train the generator for better reconstruction quality. We performed comprehensive experiments on Calgary-Campinas public brain MR dataset and compared our method with state-of-the-art MRI reconstruction methods. Ablation studies of residual learning were conducted on the MICCAI13 dataset to validate the proposed modules. Results show that our PIDD-GAN provides high-quality reconstructed MR images, with well-preserved edge information. The time of single-image reconstruction is below 5ms, which meets the demand of faster processing.
Addi. Archivo Digital para la Docencia y la Investigación
Publicación Artículo científico (JournalArticle)

Swin transformer for fast MRI

  • Huang, Jiahao
  • Fang, Yingying
  • Wu, Yinzhe
  • Wu, Huanjun
  • Gao, Zhifan
  • Li, Yang
  • Del Ser Lorente, Javier
  • Xia, Jun
  • Yang, Guang
Magnetic resonance imaging (MRI) is an important non-invasive clinical tool that can produce high -resolution and reproducible images. However, a long scanning time is required for high-quality MR images, which leads to exhaustion and discomfort of patients, inducing more artefacts due to voluntary movements of the patients and involuntary physiological movements. To accelerate the scanning process, methods by k-space undersampling and deep learning based reconstruction have been popularised. This work introduced SwinMR, a novel Swin transformer based method for fast MRI reconstruction. The whole network consisted of an input module (IM), a feature extraction module (FEM) and an output module (OM). The IM and OM were 2D convolutional layers and the FEM was composed of a cascaded of residual Swin transformer blocks (RSTBs) and 2D convolutional layers. The RSTB consisted of a series of Swin transformer layers (STLs). The shifted windows multi-head self-attention (W-MSA/SW-MSA) of STL was performed in shifted windows rather than the multi-head self-attention (MSA) of the original trans -former in the whole image space. A novel multi-channel loss was proposed by using the sensitivity maps, which was proved to reserve more textures and details. We performed a series of comparative studies and ablation studies in the Calgary-Campinas public brain MR dataset and conducted a downstream seg-mentation experiment in the Multi-modal Brain Tumour Segmentation Challenge 2017 dataset. The results demonstrate our SwinMR achieved high-quality reconstruction compared with other benchmark methods, and it shows great robustness with different undersampling masks, under noise interruption and on different datasets. The code is publicly available at https://github.com/ayanglab/SwinMR., This work was supported in part by the UK Research and Innovation Future Leaders Fellowship [MR/V023799/1] , in part by the Medical Research Council [MC/PC/21013] , in part by the European Research Council Innovative Medicines Initiative [DRAGON,H2020-JTI-IMI2 101005122] , in part by the AI for Health Imaging Award [CHAIMELEON, H2020-SC1-FA-DTS-2019-1 952172] , in part by the British Heart Foundation [Project Number: TG/18/5/34111, PG/16/78/32402] , in part by the NVIDIA Academic Hardware Grant Program, in part by the Project of Shenzhen International Cooper-ation Foundation [GJHZ20180926165402083] , in part by the Bas-que Government through the ELKARTEK funding program [KK-2020/00049] , and in part by the consolidated research group MATHMODE [IT1294-19] .
Addi. Archivo Digital para la Docencia y la Investigación
Publicación Artículo científico (JournalArticle)

Data harmonisation for information fusion in digital healthcare: A state-of-the-art systematic review, meta-analysis and future research directions

  • Nan, Yang
  • Del Ser Lorente, Javier
  • Walsh, Simon
  • Schönlieb, Carola
  • Roberts, Michael
  • Selby, Ian
  • Howard, Kit
  • Owen, John
  • Neville, Jon
  • Guiot, Julien
  • Ernst, Benoit
  • Jiménez Pastor, Ana
  • Alberich Bayarri, Ángel
  • Menzel, Marion I.
  • Walsh, Sean
  • Vos, Wim
  • Flerin, Nina
  • Charbonnier, Jean Paul
  • van Rikxoort, Eva
  • Chatterjee, Avishek
  • Woodruff, Henry
  • Lambin, Philippe
  • Cerdá Alberich, Leonor
  • Martí Bonmatí, Luis
  • Herrera Triguero, Francisco
  • Yang, Guang
Removing the bias and variance of multicentre data has always been a challenge in large scale digital healthcare studies, which requires the ability to integrate clinical features extracted from data acquired by different scanners and protocols to improve stability and robustness. Previous studies have described various computational approaches to fuse single modality multicentre datasets. However, these surveys rarely focused on evaluation metrics and lacked a checklist for computational data harmonisation studies. In this systematic review, we summarise the computational data harmonisation approaches for multi-modality data in the digital healthcare field, including harmonisation strategies and evaluation metrics based on different theories. In addition, a comprehensive checklist that summarises common practices for data harmonisation studies is proposed to guide researchers to report their research findings more effectively. Last but not least, flowcharts presenting possible ways for methodology and metric selection are proposed and the limitations of different methods have been surveyed for future research., This study was supported in part by the European Research Council Innovative Medicines Initiative (DRAGON#, H2020-JTI-IMI2 101005122), the AI for Health Imaging Award (CHAIMELEON##, H2020-SC1-FA-DTS-2019-1 952172), the UK Research and Innovation Future Leaders Fellowship (MR/V023799/1), the British Heart Foundation (Project Number: TG/18/5/34111, PG/16/78/32402), the SABRE project supported by Boehringer Ingelheim Ltd, the European Union's Horizon 2020 research and innovation programme (ICOVID, 101016131), the Euskampus Foundation (COVID19 Resilience, Ref. COnfVID19), and the Basque Government (consolidated research group MATHMODE, Ref. IT1294-19, and 3KIA project from the ELKARTEK funding program, Ref. KK-2020/00049).