Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

New Upper Limit on the Axion-Photon Coupling with an Extended CAST Run with a Xe-Based Micromegas Detector

  • Altenmüller, K.
  • Anastassopoulos, V.
  • Cogollos, Cristian
  • CAST Collaboration
CAST Collaboration: K. Altenmüller et al., Hypothetical axions provide a compelling explanation for dark matter and could be emitted from the hot solar interior. The CERN Axion Solar Telescope has been searching for solar axions via their back conversion to x-ray photons in a 9-T 10-m long magnet directed toward the Sun. We report on an extended run with the International Axion Observatory pathfinder detector, doubling the previous exposure time. The detector was operated with a xenon-based gas mixture for part of the new run, providing technical insights for future configurations. No counts were detected in the 95% signal-encircling region during the new run, while 0.75 were expected. The new data improve the axion-photon coupling limit to 5.8×10−11  GeV−1 at 95% CL (for 𝑚𝑎≲0.02  eV), the most restrictive experimental limit to date., We thank CERN for hosting the experiment and for technical support to operate the magnet and cryogenics. We thank V. Burwitz, G. Hartner of the MPE PANTER x-ray test facility for providing the opportunity to calibrate the x-ray telescope and for assistance in collecting and analysing the characterization data. We acknowledge support from NSERC (Canada); MSE (Croatia); CEA (France); BMBF (Germany) under the Grants No. 05 CC2EEA/9 and No. 05 CC1RD1/0, DFG (Germany) under Grants No. HO 1400/7-1 and No. EXC-153, GSRI (Greece); Agence Nationale de la Recherche (France) ANR-19-CE31-133 0024; the Spanish Agencia Nacional de Investigación (AEI) under Grants No. PID2019–108122 GB-C31 and No. PID2022-137268NB-C51, funded by MCIN/AEI/10.13039/501100011033/FEDER, as well as the “Planes complementarios, Programa de Astrofísica y Física de Altas Energías” from the “European Union NextGenerationEU/PRTR” funds; the University of Rijeka with Grant No. 18-126 and Projects No. KK.01.1.01.0001 and No. RC.2.2.06.-0001 financed by the EU; the European Research Council (ERC) under Grants No. ERC-2017-AdG 788781 ( IAXO + ) and No. ERC 802836; the Marie Skłodowska-Curie Grant Agreement No. 101026819 (LOBRES); Turkish Atomic Energy Authority (TAEK); NSF (USA) under Grant No. 0239812; NASA under the Grant No. NAG5-10842; and IBS (Korea) with code IBS-R017-D1. Part of this work was performed under the auspices of the US Department of Energy by Lawrence Livermore National Laboratory under Contract No. DE-AC52-07NA27344 and funded through Lawrence Livermore National Laboratory Directed Research and Development project LDRD-17-ERD-030., Peer reviewed
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Micromegas with GEM preamplification for enhanced energy threshold in low-background gaseous time projection chambers

  • Castel Pablo, Juan Francisco
  • Cebrián Guajardo, Susana
  • Dafni, Theopisti
  • Díez Ibáñez, David
  • Galán Lacarra, Javier
  • García Pascual, Juan Antonio
  • Ezquerro Sastre, Álvaro
  • García Irastorza, Igor
  • Luzón Marco, Gloria
  • Margalejo Blasco, Cristina
  • Mirallas Sánchez, Héctor
  • Obis Aparicio, Luis
  • Ortiz de Solórzano, Alfonso
  • Pérez Lázaro, Óscar
  • Porrón Lafuente, Jorge
  • Jiménez Puyuelo, María
Background We develop the concept of a Micromegas readout plane with an additional GEM preamplification stage placed a few millimetres above it to increase the maximum effective gain of the combined readout. Methods We implement it and test it in realistic conditions for its application to low-background dark matter searches like the TREX-DM experiment. For this, we use a Micromegas of Microbulk type, built with radiopure materials. Results We report on GEM effective extra gain factors of about 90, 50 and 20 in 1, 4 and 10 bar of Ar-1%iC4H10. These results are obtained in a small test chamber allowing for systematic scanning of voltages and pressures. In addition, a TREX-DM full-scale set-up has also been built and tested, featuring a replica of the fully-patterned TREX-DM Microbulk readout. Conclusions The results here obtained show promise to lower the threshold of the experiment down to 50 eV ee , corresponding to substantially enhanced sensitivity to low-mass WIMPs.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Detecting supernova axions with IAXO

  • Carenza, P.
  • García Pascual, J. A.
  • Giannotti, M.
  • Irastorza, I. G.
  • Kaltschmidt, M.
  • Lella, A.
  • Lindner, A.
  • Lucente, G.
  • Mirizzi, A.
  • Jiménez Puyuelo, M.
  • Schiffer, T.
We investigate the potential of IAXO and its intermediate version, BabyIAXO, to detect axions produced in core-collapse supernovae (SNe). Our study demonstrates that these experiments have realistic chances of identifying SN axions, offering crucial insights into both axion physics and SN dynamics. IAXO's sensitivity to SN axions allows for the exploration of regions of the axion parameter space inaccessible through solar observations. In addition, in the event of a nearby SN, d ∼ (100) pc, and sufficiently large axion couplings, gaγ ≳ 10-11 GeV-1, IAXO could have a chance to significantly advance our understanding of axion production in nuclear matter and provide valuable information about the physics of SNe, such as pion abundance, the equation of state, and other nuclear processes occurring in extreme environments.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Using Micromegas Detectors for Direct Dark Matter Searches: Challenges and Perspectives

  • Luzón, Gloria
  • Dafni, Theopisti
  • Altelmueller, Konrad
  • Antolín, Itxaso
  • Calvet, Denis
  • Candón, Francisco
  • Cebrián, Susana
  • Castel, Juan
  • Cogollos, Cristian
  • Díez Ibáñez, David
  • Ferrer-Ribas, Esther
  • Galán, Javier
  • García, Juan Antonio
  • Gómez, Héctor
  • Gu, Yikun
  • Ezquerro, Álvaro
  • García Irastorza, Igor
  • Margalejo, Cristina
  • Mirallas, Héctor
  • Porrón, Jorge
  • Quintana, Ana
  • Obis, Luis
  • Ortiz de Solorzano, Alfonso
  • Papaevangelou, Thomas
  • Pérez, Óscar
  • Picatoste, Eduardo
  • Jiménez Puyuelo, María
  • Ruiz-Chóliz, Elisa
  • Ruz, Jaime
  • Vogel, Julia
Gaseous Time Projection Chambers (TPCs) with Micromegas pixelated readouts are being used in darkmatter searches and other rare-event searches, due to their potential in terms of low background levels, energy and spatial resolution, gain, and operational stability. Moreover, these detectors can provideprecious features, such as topological information, allowing for event directionality and powerful signalbackground discrimination. The Micromegas technology of the microbulk type is particularly suited tolow-background applications and is being exploited by detectors for CAST and IAXO (solar axions) andTREX-DM (low-mass WIMPs) experiments. Challenges for the future include reducing intrinsic background levels, reaching lower energy detection levels, and technical issues such as robustness of the detector, new design choices, novel gas mixtures and operation points, scaling up to larger detector sizes,handling large readout granularity, etc. We report on the status and prospects of the development ongoing in the context of IAXO and TREX-DM experiments, pointing to promising perspectives for the use ofMicromegas detectors in direct dark matter searches.