Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Association of cut-point free metrics and common clinical tests among older adults after proximal femoral fracture

  • Younesian, Hananeh
  • Singleton, David
  • Vereijken, Beatrix
  • García Aymerich, Judith
  • Rochester, Lynn
  • Aursand Berge, Martin
  • Engdal, Monika
  • Buekers, Joren
  • Koch, Sarah
  • Helbostad, Jorunn L.
  • Alvarez, Paula
  • Jansen, Carl-Philipp
  • Aminian, Kamiar
  • Paraschiv-Ionescu, Anisoara
  • Becker, Clemens
  • Caulfield, Brian
  • Mobilise-D consortium
Wearable and lightweight devices facilitate real-world physical activity (PA) assessments. MX metrics, as a cut-point-free parameter, evaluate acceleration above which the most active X minutes are accumulated. It provides insights into the intensity of PA over specific durations. This study evaluated the association of MX metrics and clinical tests in older adults recovering from proximal femoral fracture (PFF). Analyses were conducted on the PFF cohort from the baseline assessment of the Mobilise-D project using an accelerometer-based device. Participants (N = 396) were categorized into four recovery groups: acute, post-acute, extended recovery, and long-term recovery. Mobility capacity was assessed through the 6 min walking test (6MinWT), Short Physical Performance Battery (SPPB), 4-m walking test (4MWT), and hand grip (HG) strength. Mobility perception was evaluated using the Late-Life Function and Disability Instrument (LLFDI). Eight MX metrics (M1-M90) were calculated using the GGIR package in R. Results showed a moderate to strong positive correlation between M1 and M30 and lower limb mobility capacity tests and mobility perception (Lower Extremity domains) particularly in the extended and long-term recovery groups. MX metrics can be used for measuring PA intensity among older adults recovering from PFF. Hence, MX metrics have a high potential for clinical use as personalized PA targets in PFF rehabilitation., H.Y. has received funding from the European Union’s Horizon 2020 research and innovation program under the Marie Skłodowska-Curie grant agreement No 101034252. This research is supported by Taighde Éireann—Research Ireland. The Mobilise-D consortium received funding from the Innovative Medicines Initiative 2 Joint Undertaking under grant agreement No 820820. This Joint Undertaking receives support from the European Union’s Horizon 2020 research and innovation program and EFPIA.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

An Exploratory Study on the Utility of Patient-Generated Health Data as a Tool for Health Care Professionals in Multiple Sclerosis Care

  • Guardado, Sharon
  • Mylonopoulou, Vasiliki
  • Rivera-Romero, Octavio
  • Patt, Nadine
  • Bansi, Jens
  • Giunti, Guido
[EN] Background Patient-generated health data (PGHD) are data collected through technologies such as mobile devices and health apps. The integration of PGHD into health care workflows can support the care of chronic conditions such as multiple sclerosis (MS). Patients are often willing to share data with health care professionals (HCPs) in their care team; however, the benefits of PGHD can be limited if HCPs do not find it useful, leading patients to discontinue data tracking and sharing eventually. Therefore, understanding the usefulness of mobile health (mHealth) solutions, which provide PGHD and serve as enablers of the HCPs' involvement in participatory care, could motivate them to continue using these technologies.Objective The objective of this study is to explore the perceived utility of different types of PGHD from mHealth solutions which could serve as tools for HCPs to support participatory care in MS.Method A mixed-methods approach was used, combining qualitative research and participatory design. This study includes three sequential phases: data collection, assessment of PGHD utility, and design of data visualizations. In the first phase, 16 HCPs were interviewed. The second and third phases were carried out through participatory workshops, where PGHD types were conceptualized in terms of utility.Results The study found that HCPs are optimistic about PGHD in MS care. The most useful types of PGHD for HCPs in MS care are patients' habits, lifestyles, and fatigue-inducing activities. Although these subjective data seem more useful for HCPs, it is more challenging to visualize them in a useful and actionable way.Conclusion HCPs are optimistic about mHealth and PGHD as tools to further understand their patients' needs and support care in MS. HCPs from different disciplines have different perceptions of what types of PGHD are useful; however, subjective types of PGHD seem potentially more useful for MS care., The More Stamina project has received funding from Business Finland, and O.R.-R. has received funding from the Universidad de Sevilla and the Ministerio de Universidades of the Spanish Government under the call"Recualificacion del Sistema Espanol de Universidades" funded by European Union-NextGeneration EU. The study was partly funded by the EU's Horizon 2020 Research and Innovation Programme under the Marie Sklodowska-Curie grant agreement No. 101034252 and by a research grant from Science Foundation Ireland (SFI) under Grant Number 16/RC/3948.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Association of cut-point free metrics and common clinical tests among older adults after proximal femoral fracture

  • Younesian, Hananeh
  • Singleton, David
  • Vereijken, Beatrix
  • García Aymerich, Judith
  • Rochester, Lynn
  • Aursand Berge, Martin
  • Engdal, Monika
  • Buekers, Joren
  • Koch, Sarah
  • Helbostad, Jorunn L.
  • Alvarez, Paula
  • Jansen, Carl-Philipp
  • Aminian, Kamiar
  • Paraschiv-Ionescu, Anisoara
  • Becker, Clemens
  • Caulfield, Brian
  • Mobilise-D consortium
Wearable and lightweight devices facilitate real-world physical activity (PA) assessments. MX metrics, as a cut-point-free parameter, evaluate acceleration above which the most active X minutes are accumulated. It provides insights into the intensity of PA over specific durations. This study evaluated the association of MX metrics and clinical tests in older adults recovering from proximal femoral fracture (PFF). Analyses were conducted on the PFF cohort from the baseline assessment of the Mobilise-D project using an accelerometer-based device. Participants (N = 396) were categorized into four recovery groups: acute, post-acute, extended recovery, and long-term recovery. Mobility capacity was assessed through the 6 min walking test (6MinWT), Short Physical Performance Battery (SPPB), 4-m walking test (4MWT), and hand grip (HG) strength. Mobility perception was evaluated using the Late-Life Function and Disability Instrument (LLFDI). Eight MX metrics (M1-M90) were calculated using the GGIR package in R. Results showed a moderate to strong positive correlation between M1 and M30 and lower limb mobility capacity tests and mobility perception (Lower Extremity domains) particularly in the extended and long-term recovery groups. MX metrics can be used for measuring PA intensity among older adults recovering from PFF. Hence, MX metrics have a high potential for clinical use as personalized PA targets in PFF rehabilitation., H.Y. has received funding from the European Union’s Horizon 2020 research and innovation program under the Marie Skłodowska-Curie grant agreement No 101034252. This research is supported by Taighde Éireann—Research Ireland. The Mobilise-D consortium received funding from the Innovative Medicines Initiative 2 Joint Undertaking under grant agreement No 820820. This Joint Undertaking receives support from the European Union’s Horizon 2020 research and innovation program and EFPIA.