Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Proof of concept validation of bioresorbable optical fibers for diffuse correlation spectroscopy

  • Pandayil, Jawad T.
  • Boetti, Nadia G.
  • Janner, Davide
  • Durduran, Turgut
  • Cortese, Lorenzo
Optical quality bioresorbable materials have been gaining interest in recent years for various interstitial biomedical/medical application. An example of this is when the implant gradually dissolves in the body, providing physiological information over extended periods of time, hence reducing the need for revision surgeries. This study reports for the first time the in-house fabrication of single mode (at 785 nm) calcium phosphate glass (CPG) based bioresorbable optical fibers and investigates their suitability for microvascular blood flow monitoring using diffuse correlation spectroscopy (DCS). Ex vivo experiments in liquid phantom and non-invasive in vivo experiments on the human forearm muscle were conducted using multimode and single mode CPG bioresorbable optical fibers. The retrieved flow index from the correlation curves acquired using CPG fibers was in good agreement with that obtained using standard silica (Si) fibers, both ex vivo and in vivo. The results demonstrate the potential of CPG optical fibers for further exploration., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Near-infrared diffuse optical characterization of human thyroid using ultrasound-guided hybrid time-domain and diffuse correlation spectroscopies

  • Fernández Esteberena, Pablo
  • Cortese, Lorenzo
  • Zanolotti, Marta
  • Lo Presti, Giuseppe
  • Aranda Velázquez, Gloria
  • Ruiz Janer, Sabina
  • Buttafava, Mauro
  • Renna, Marco
  • Di Sieno, Laura
  • Tosi, Alberto
  • Dalla Mora, Alberto
  • Wojtkewicz, Stanislaw
  • Dehbhani, Hamid
  • de Fraguier, Sixte
  • Nguyen-Dinh, An
  • Rosinski, Bogdan
  • Weigel, Udo M.
  • Sarangi, Dibya J.
  • Squarcia, Mattia
  • hanzu, Felicia A.
  • Contini, Davide
  • Mora Porta, Mireia
  • Durduran, Turgut
Thyroid vascularization and hemodynamics become altered in thyroid pathologies and could thus inform diagnostics, therapy planning, and follow-up. However, the current non-invasive monitoring methods available in clinics lack the necessary sensitivity and/or are impractical for large-scale deployment. As a step towards proposing a new modality, we applied the first platform, to our knowledge, designed to do simultaneous measurements of neck anatomy and thyroid microvascular hemodynamics and metabolism in a single probe placement, integrating state-of-the-art near-infrared spectroscopy techniques and clinical ultrasound. A rich dataset was formed with sixty-five subjects (forty-eight females), including eighteen healthy volunteers and forty-seven patients with thyroid nodules, characterizing thyroid tissue and the effects of demographic and anatomical variables while preserving the standard clinical workflow. We have found marked reductions with age and body mass index in thyroid total hemoglobin concentration (THC), tissue oxygen saturation (StO2), and blood flow index (BFi), among others. Patients showed lower THC and BFi than healthy subjects, and the limited sample of malignant nodules showed a higher StO2 than the benign. These findings support the need for personalized clinical approaches., Peer Reviewed
Recercat. Dipósit de la Recerca de Catalunya
Publicación

On-skin, micro-objective enabled camera module for speckle contrast optical spectroscopy/tomography

  • Quiroga, Andres
  • Cortese, Lorenzo
  • Verma, Manish
  • Dannberg, Peter
  • Tachtsidis, Ilias
  • Danz, Norbert
  • Durduran, Turgut
In this paper, we introduce a speckle contrast optical spectroscopy/tomography (SCOS/SCOT) configuration based on an integrated imaging approach exploiting 113 microobjectives mounted on a commercial CMOS camera that operates without fiber coupling, suitable for direct skin contact measurements and simultaneous multiple source-detector separation acquisitions. This compact system was validated ex vivo on phantoms and in vivo by monitoring the blood flow on the forearm muscle of a healthy human subject. The measurements, performed at multiple source-detector separations and camera exposure times, demonstrate excellent agreement with the theory based on the correlation-diffusion model. In vivo data demonstrate the capability of tracking pulsatile blood flow with a high signal-to-noise ratio (>4 harmonics of the cardiac pulse frequency detected) and sensitivity to small changes in muscle blood flow. This micro-objective array-based design overcomes a key challenge towards wearable SCOS/SCOT devices., Peer Reviewed
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Proof of concept validation of bioresorbable optical fibers for diffuse correlation spectroscopy

  • Pandayil, Jawad T.
  • Boetti, Nadia G.
  • Janner, Davide
  • Durduran, Turgut
  • Cortese, Lorenzo
Optical quality bioresorbable materials have been gaining interest in recent years for various interstitial biomedical/medical application. An example of this is when the implant gradually dissolves in the body, providing physiological information over extended periods of time, hence reducing the need for revision surgeries. This study reports for the first time the in-house fabrication of single mode (at 785 nm) calcium phosphate glass (CPG) based bioresorbable optical fibers and investigates their suitability for microvascular blood flow monitoring using diffuse correlation spectroscopy (DCS). Ex vivo experiments in liquid phantom and non-invasive in vivo experiments on the human forearm muscle were conducted using multimode and single mode CPG bioresorbable optical fibers. The retrieved flow index from the correlation curves acquired using CPG fibers was in good agreement with that obtained using standard silica (Si) fibers, both ex vivo and in vivo. The results demonstrate the potential of CPG optical fibers for further exploration., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Near-infrared diffuse optical characterization of human thyroid using ultrasound-guided hybrid time-domain and diffuse correlation spectroscopies

  • Fernández Esteberena, Pablo
  • Cortese, Lorenzo
  • Zanolotti, Marta
  • Lo Presti, Giuseppe
  • Aranda Velázquez, Gloria
  • Ruiz Janer, Sabina
  • Buttafava, Mauro
  • Renna, Marco
  • Di Sieno, Laura
  • Tosi, Alberto
  • Dalla Mora, Alberto
  • Wojtkewicz, Stanislaw
  • Dehbhani, Hamid
  • de Fraguier, Sixte
  • Nguyen-Dinh, An
  • Rosinski, Bogdan
  • Weigel, Udo M.
  • Sarangi, Dibya J.
  • Squarcia, Mattia
  • hanzu, Felicia A.
  • Contini, Davide
  • Mora Porta, Mireia
  • Durduran, Turgut
Thyroid vascularization and hemodynamics become altered in thyroid pathologies and could thus inform diagnostics, therapy planning, and follow-up. However, the current non-invasive monitoring methods available in clinics lack the necessary sensitivity and/or are impractical for large-scale deployment. As a step towards proposing a new modality, we applied the first platform, to our knowledge, designed to do simultaneous measurements of neck anatomy and thyroid microvascular hemodynamics and metabolism in a single probe placement, integrating state-of-the-art near-infrared spectroscopy techniques and clinical ultrasound. A rich dataset was formed with sixty-five subjects (forty-eight females), including eighteen healthy volunteers and forty-seven patients with thyroid nodules, characterizing thyroid tissue and the effects of demographic and anatomical variables while preserving the standard clinical workflow. We have found marked reductions with age and body mass index in thyroid total hemoglobin concentration (THC), tissue oxygen saturation (StO2), and blood flow index (BFi), among others. Patients showed lower THC and BFi than healthy subjects, and the limited sample of malignant nodules showed a higher StO2 than the benign. These findings support the need for personalized clinical approaches., Peer Reviewed, Postprint (published version)