Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

A Method for Visualizing Corneal Dynamics Through Pixel Intensity Tracking

  • Ramos Arizcuren, Ana M.
  • Consejo, Alejandra
Purpose: To develop a methodology for analyzing dynamic corneal images using pixel intensity tracking and hue, saturation, and value (HSV) color space transformation, aiming to quantify and visually interpret corneal responsiveness to mechanical stimulation. Methods: This study utilized the OCULUS Corvis ST device to obtain dynamic corneal images from two subject groups (young and older individuals). To ensure accurate pixel tracking, segmentation and registration techniques were implemented. To counteract potential biases due to alterations in curvature and eye retraction caused by the air-puff mechanical stimulus, the last 30 frames available post-stimulus were used for analysis. Pixel intensity tracking calculations were then performed in the frequency domain to compute H, S, and V values for each pixel within the overall region of interest. Additionally, corneal biomechanical parameters from the Corvis ST were extracted to examine their relationship with HSV values. Results: The HSV transformation provided a quantitative visual interpretation of corneal dynamics, with reddish vibrant areas indicating higher responsiveness to mechanical stimulation and dull blue areas indicating lower responsiveness. Additionally, significant differences were found between the young and older groups in each of the three HSV channels (all P < 0.001). Four biomechanical parameters showed statistically significant differences between groups (P < 0.05), but no statistically significant correlation with HSV values was found. Conclusions: The HSV methodology effectively visualizes and quantifies corneal responsiveness to mechanical stimulation, offering a new approach for assessing corneal dynamics. Translational Relevance: HSV color space analysis has the potential to enhance the diagnosis and management of conditions in which corneal dynamics are affected.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Deep learning-based keratoconus detection from Scheimpflug images

  • Casado-Moreno, Juan
  • Masia, Belén
  • Lu, Nanji
  • Cui, Lele
  • Consejo, Alejandra
This study evaluates the effectiveness of deep learning techniques applied to raw Scheimpflug corneal images for keratoconus detection, with a particular focus on forme fruste (FF) keratoconus, which refers to preclinical cases. Using an original dataset of 22,750 images from 910 eyes, a deep learning model based on transfer learning with a pre-trained VGG16 architecture was trained, incorporating specific preprocessing steps and data augmentation strategies. The proposed approach achieved an overall accuracy of 90.70%, with a sensitivity of 80.57%, and a specificity of 80.56% for FF keratoconus classification, and an AUC of 0.89. For clinical keratoconus, the model demonstrated a sensitivity of 93.28%, a specificity of 99.40%, and an AUC of 1.00. These findings highlight the potential of leveraging raw Scheimpflug images in deep learning-based keratoconus detection, particularly for identifying early-stage structural changes that may not be apparent in conventional topographic assessments.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Influence of iris color on corneal densitometry

  • Arizcuren, Ana R.
  • Consejo, Alejandra
Purpose: To determine whether iris pigmentation introduces a measurable bias in corneal densitometry (CD) values obtained via Scheimpflug imaging, and to develop an objective metric for iris color quantification. Methods: This observational study included 91 eyes from 47 healthy adults. CD was assessed as mean pixel intensity (MPI) from 25 Scheimpflug images per eye. Brightness artefacts from the iris were quantified using automated image processing. Iris color was objectively characterized from slit-lamp photographs using an objective singlevalue metric (IrisColor) derived from normalized CIELAB components. Associations among CD, iris brightness, and iris pigmentation were evaluated using Pearson correlation and linear mixed-effects models (LMMs). Results: CD correlated positively with iris brightness artefacts (r = 0.47, β = 1.49, p < 0.001), which in turn showed a strong negative correlation with IrisColor (r = −0.83, β = −1.11, p < 0.001). Lighter-colored irises (lower IrisColor values) exhibited statistically significantly higher CD values equivalent to a 6.6% relative overestimation. Groupwise comparisons confirmed that iris pigmentation significantly influences both CD and overall image brightness. Conclusion: Iris pigmentation induces a measurable bias in Scheimpflug-based CD estimates, primarily through increased brightness artefacts in light-colored eyes. The proposed IrisColor metric enables objective, continuous classification of iris color and could support future corrections for pigmentation-induced bias in CD-based diagnostics.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Estimating the optical properties of corneal tissue from the OCT speckle

  • Miazdzyk, Maria
  • Consejo, Alejandra
  • Iskander, D. Robert
Estimating the scattering coefficient µs and scattering anisotropy factor g of the corneal tissue is currently limited to methods utilizing double integrating spheres or spectroscopic techniques, prohibiting such corneal tissue evaluation from being performed in a clinical setting. This paper presents a new concept of statistical matching between a given corneal optical coherence tomography (OCT) scan and a set of multi-reference phantom OCT B-scans, suitably simulated using the Monte Carlo method. The statistical matching that exploits the information present in the speckle includes an ensemble of distance measures. Using a set of OCT scans from 11 porcine eyeballs, for which epithelium was removed, it is demonstrated that the proposed statistical matching approach leads to a precise estimation of the optical properties of corneal stroma. The group mean of the scattering coefficient and the scattering anisotropy factor for the porcine stroma were µ¯s = 0.146 ± 0.020 mm−1 and g¯ = 0.893 ± 0.021, respectively. These estimates match previously reported values established with other methods. The proposed approach of utilizing information present in the speckle can be readily extended to in vivo OCT imaging of human corneal tissue.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Combination of tissue-derived and shape-based parameters for subclinical keratoconus detection

  • Casado-Moreno, Juan
  • Ramos Arizcuren, Ana
  • Rozema, Jos J.
  • Consejo, Alejandra
This study investigates whether combining clinically conventional shape-based tomographic parameters and image-derived descriptors extracted from raw Scheimpflug corneal images improves the detection of subclinical keratoconus (SKC). A dataset of 186 eyes (30 SKC and 156 controls) was analyzed, from which 100 candidate parameters were computed, encompassing both shape-based indices and image-derived metrics based on statistical, textural, and frequency-domain features. Feature selection using bootstrapping identified a subset of five highly discriminative parameters, comprising three image-derived descriptors and two shape-based metrics used to construct a directly interpretable predictive equation. When evaluated with an XGBoost classifier, this reduced 5-feature set achieved an overall accuracy of 96.78% and an area under the ROC curve of 0.993, closely matching the performance obtained using the full feature set. These results demonstrate that integrating image-derived information with traditional morphological parameters enhances SKC detection while maintaining interpretability, providing a practical and clinically translatable framework for subclinical-stage keratoconus screening.