Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 6
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Silicon Photonics Grating Coupler Array for Light Collection in Optical Wireless Communication

  • Wolny, Mikolaj
  • Koonen, Ton
  • Tangdiongga, Eduward
  • Maria Morant|||0000-0001-5565-7788
  • Roberto Llorente|||0000-0003-4799-2564
[EN] The receivers for Optical Wireless Communication (OWC) need to meet the challenging requirements for high-capacity data transmission. Photonic Integrated Circuits (PIC) allow separation of light collection and light detection. In this way, both functions can be optimized separately. Light can be coupled into a PIC from free space through a Surface Grating Coupler (SGC) and detected with a high-speed photodiode. This separation enables additional processing of light between the collection and detection, such as amplification or mixing with a local oscillator for coherent detection. In this paper, we focus on optimization of the light collection part of the receiver for OWC. We present a "windmill" array of SGC fabricated on a Silicon-on-Insulator (SOI) platform. The SOI SGC array consists of four focusing 85 mu m-long SGCs with 90 degrees opening angle (240-mu m array diameter) with measured vertical -3-dB field of view (FoV) of >6 degrees, and -7-dB 360 degrees horizontal FoV. We achieved error-free optical wireless data transmission of 8 Gbps NRZ OOK over a distance of 15 cm. The PIC structure presented here is a promising candidate for future advanced OWC receivers., This work was supported in part by the Nederlandse Organisatie Voo rWetenschappelijk Onderzoek (NWO, Dutch Research Council) under Grant 12128, in part by Optical Wireless Superhighways: Free Photons and in partby the Spanish Ministry of Science and Innovation Project iPHOEBE fundedby MCIU /AEI /10.13039/501100011033 / FEDER, UE, under Grant PID2023-152410OB-I00.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Optical microfluidic system based on ionophore modified gold nanoparticles for the continuous monitoring of mercuric ion

  • Gómez-De Pedro, S.
  • Lopes, D.
  • Miltsov, S.
  • Izquierdo, D.
  • Alonso-Chamarro, J.
  • Puyol, M.
An optical microfluidic system based on the use of modified gold nanoparticles for monitoring Hg(II) is presented. The system is based on the specific recognition of the heavy metal by a new synthesized ionophore based on a modified thiourea, which is attached to the gold nanoparticles. This interaction generates a change on the gold Surface Plasmon Resonance (SPR) band. The sensitivity and selectivity of the procedure is firstly studied in batch. The obtained results demonstrate the mercury selective response over the different tested ions that can be found in environmental water samples. Due to the remarkable unusual rapid signal change observed during the interaction of the metal and the modified gold nanoparticles, the reaction can be easily performed in a microfluidic system. Results obtained by using the microfluidic system revealed improved analytical features compared to batch experiments such as a lower detection limit (11 ppb), higher sensitivity and faster analysis time, all this with an easy and automated procedure. Therefore, the approach has shown great potential for designing low cost instrumentation for automatic in-field discrete or continuous measurements of Hg(II).
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Multi-parametric polymer-based potentiometric analytical microsystem for future manned space missions

  • Calvo-López, Antonio|||0000-0003-2728-8676
  • Puyol, Mar|||0000-0002-9274-2284
  • Casalta, Joan Manel
  • Alonso-Chamarro, Julián|||0000-0002-6804-6027
The construction and evaluation of a Cyclic Olefin Copolymer (COC)-based continuous flow potentiometric microanalyzer to simultaneously monitor potassium, chloride and nitrate ions in samples from an on-board water recycling process expected to be installed in future manned space missions is presented. The main goals accomplished in this work address the specific required characteristics for a miniaturized on-line monitoring system to control water quality in such missions. To begin with, the integration of three ion-selective electrodes (ISEs) and a reference electrode in a compact microfluidic platform that incorporates a simple automatic autocalibration process allows obtaining information about the concentration of the three ions with optimal analytical response characteristics, but moreover with low reagents consumption and therefore with few waste generation, which is critical for this specific application. By a simple signal processing (signal removal) the chloride ion interference on the nitrate electrode response can be eliminated. Furthermore, all fluidics management is performed by computer-controlled microvalves and micropumps, so no manual intervention of the crew is necessary. The analytical features provided by the microsystem after the optimization process were a linear range from 6.3 to 630 mg L-1 and a detection limit of 0.51 mg L-1 for the potassium electrode, a linear range from 10 to 1000 mg L-1 and a detection limit of 1.58 mg L-1 for the chloride electrode and a linear range from 10 to 1000 mg L-1 and a detection limit of 3.37 mg L-1 for the nitrate electrode with a reproducibility (RSD) of 4%, 2% and 3% respectively. Sample throughput was 12 h-1 with a reagent consumptions lower than 2 mL per analysis.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Potentiometric analytical microsystem based on the integration of a gas-diffusion step for on-line ammonium determination in water recycling processes in manned space missions

  • Calvo-López, Antonio|||0000-0003-2728-8676
  • Ymbern Llorens, Oriol|||0000-0003-1997-6794
  • Puyol, Mar|||0000-0002-9274-2284
  • Casalta, Joan Manel
  • Alonso-Chamarro, Julián|||0000-0002-6804-6027
The design, construction and evaluation of a versatile cyclic olefin copolymer (COC)-based continuous flow potentiometric microanalyzer to monitor the presence of ammonium ion in recycling water processes for future manned space missions is presented. The microsystem integrates microfluidics, a gas-diffusion module and a detection system in a single substrate. The gas-diffusion module was integrated by a hydrophobic polyvinylidene fluoride (PVDF) membrane. The potentiometric detection system is based on an all-solid state ammonium selective electrode and a screen-printed Ag/AgCl reference electrode. The analytical features provided by the analytical microsystem after the optimization process were a linear range from 0.15 to 500mgL-1 and a detection limit of 0.07±0.01mgL-1. Nevertheless, the operational features can be easily adapted to other applications through the modification of the hydrodynamic variables of the microfluidic platform.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Gas diffusion as a new fluidic unit operation for centrifugal microfluidic platforms

  • Ymbern Llorens, Oriol|||0000-0003-1997-6794
  • Sández, Natàlia|||0000-0003-1712-3552
  • Calvo-López, Antonio|||0000-0003-2728-8676
  • Puyol, Mar|||0000-0002-9274-2284
  • Alonso-Chamarro, Julián|||0000-0002-6804-6027
A centrifugal microfluidic platform prototype with an integrated membrane for gas diffusion is presented for the first time. The centrifugal platform allows multiple and parallel analysis on a single disk and integrates at least ten independent microfluidic subunits, which allow both calibration and sample determination. It is constructed with a polymeric substrate material and it is designed to perform colorimetric determinations by the use of a simple miniaturized optical detection system. The determination of three different analytes, sulfur dioxide, nitrite and carbon dioxide, is carried out as a proof of concept of a versatile microfluidic system for the determination of analytes which involve a gas diffusion separation step during the analytical procedure.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Biparametric potentiometric analytical microsystem for nitrate and potassium monitoring in water recycling processes for manned space missions

  • Calvo-López, Antonio|||0000-0003-2728-8676
  • Arasa-Puig, Eva|||0000-0002-0702-0069
  • Puyol, Mar|||0000-0002-9274-2284
  • Casalta, Joan Manel
  • Alonso-Chamarro, Julián|||0000-0002-6804-6027
The construction and evaluation of a Low Temperature Co-fired Ceramics (LTCC)-based continuous flow potentiometric microanalyzer prototype to simultaneously monitor the presence of two ions (potassium and nitrate) in samples from the water recycling process for future manned space missions is presented. The microsystem integrates microfluidics and the detection system in a single substrate and it is smaller than a credit card. The detection system is based on two ion-selective electrodes (ISEs), which are built using all-solid state nitrate and potassium polymeric membranes, and a screen-printed Ag/AgCl reference electrode. The obtained analytical features after the optimization of the microfluidic design and hydrodynamics are a linear range from 10 to 1000mgL-1 and from 1.9 to 155mgL-1 and a detection limit of 9.56mgL-1 and 0.81mgL-1 for nitrate and potassium ions respectively.