Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Deep Learning Based Non-invasive Meningitis Screening Using High-Resolution Ultrasound in Neonates and Infants from Mozambique, Spain and Morocco

  • Jobst, Beatrice M.
  • Carandell, Francesc
  • Ajanovic, Sara
  • Sial, Hassan
  • Jiménez, Javier
  • Quesada, Rita
  • Santos, Fabião
  • Lopez-Azorín, Manuela
  • Valverde, Eva
  • Ybarra, Marta
  • Bravo, M. Carmen
  • Muñoz, David
  • Agut, Thais
  • Salas, Barbara
  • Carreras, Nuria
  • Alarcón, Ana
  • Iriondo, Martín
  • Luaces, Carles
  • Sidat, Muhammad
  • Zandamela, Mastalina
  • Rodrigues, Paula
  • Martins, Luzidina
  • Cassia, Uneisse
  • Bramugy, Justina
  • Cossa, Anelsio
  • Mucasse, Campos
  • Buck, W. Chris
  • Arias, Sara
  • El Abbass, Chaymae
  • Tligui, Houssain
  • Barkat, Amina
  • Amalik, Najat
  • Zizi, Imane
  • Ibáñez Rodríguez, Alberto
  • Parrilla, Montserrat
  • Elvira Segura, Luis
  • Calvo, Cristina
  • Pellicer, Adelina
  • Cabañas, Fernando
  • Bassat, Quique
  • Petrone, Paula
1st MICCAI Meets Africa Workshop, MImA 2024 and 1st MICCAI Student Board Workshop on Empowering Medical Information Computing and Research through Early-Career Expertise, EMERGE 2024, Held in Conjunction with MICCAI 2024. Medical Information Computing. MImA EMERGE 2024 2024. Communications in Computer and Information Science, vol 2240., Meningitis is a life-threatening disease, resulting in severe neurological damage or death if not treated in time. The standard diagnostic method is an invasive lumbar puncture (LP), not exempt of complications and not always feasible, especially in resource-poor settings. To overcome these challenges, we developed Neosonics®, a novel non-invasive high-resolution ultrasound (HRUS) technology that detects backscatter signals from white blood cells (WBCs) in cerebrospinal fluid (CSF) below the infant fontanel. Using deep learning (DL) for image analysis, this technology classifies patients based on WBC levels, providing a rapid, non-invasive screening method for infant meningitis and with this, limiting indications for LPs for positive cases only, if not contraindicated. A convolutional neural network was trained and validated using CSF HRUS patient data gathered from cohorts from three different countries, Mozambique, Spain and Morocco. Then, a soft voting ensemble-learning technique was applied to give a classification on a patient-level. The DL model showed on a single-image level a sensitivity (SE) and specificity (SP) of 71.1% and 87.0% for the Mozambican cohort, SE = 73.3% and SP = 75.5% for the Spanish cohort, and SE = 72.0% and SP = 88.7% for the Moroccan cohort. On a patient-level, the overall SE and SP was 94.4% and 94.8%, respectively. We demonstrate in this study the significance of combining HRUS and DL for the non-invasive detection of infant meningitis, offering an efficient, cost-effective solution suitable also for limited resource settings and remote areas., Kriba acknowledges support from the European Union’s Horizon Europe research and innovation programme, project code 190155553 - NEOSONICS. All authors with ISGlobal affiliation acknowledge support from the grant CEX2018-000806-S funded by MCIN/AEI/ https://doi.org/10.13039/501100011033, and support from the Generalitat de Catalunya through the CERCA Program. Mozambique: This work was supported by the Bill & Melinda Gates Foundation INV-048197. Morocco: This project was supported in part by Spanish Agency of Cooperation (AECID) under the reference number 2019/ACDE/001196. Project PI16/01822 from PI ENRIQUE BASSAT ORELLANA and project PI16/00738 funded by Instituto de Salud Carlos III, co-funded by the European Union (FEDER) “Una manera de hacer Europa”., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Non-invasive meningitis screening in neonates and infants: multicentre international study

  • THE UNITED STUDY GROUP
  • Ajanovic, Sara
  • Ibáñez Rodríguez, Alberto
  • Parrilla Romero, Montserrat
  • Elvira Segura, Luis
11 páginas, 4 figuras, 1 tabla, Background and objectives:Meningitis diagnosis requires a lumbar puncture (LP) to obtain cerebrospinal fluid (CSF) for a laboratory-based analysis. In high-income settings, LPs are part of the systematic approach to screen for meningitis, and most yield negative results. In low- and middle-income settings, LPs are seldom performed, and suspected cases are often treated empirically. The aim of this study was to validate a non-invasive transfontanellar white blood cell (WBC) counter in CSF to screen for meningitis.Methods:We conducted a prospective study across three Spanish hospitals, one Mozambican and one Moroccan hospital (2020-2023). We included patients under 24 months with suspected meningitis, an open fontanelle, and a LP performed within 24 h from recruitment. High-resolution-ultrasound (HRUS) images of the CSF were obtained using a customized probe. A deep-learning model was trained to classify CSF patterns based on LPs WBC counts, using a 30cells/mm3 threshold.Results:The algorithm was applied to 3782 images from 76 patients. It correctly classified 17/18 CSFs with >=\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\ge$$\end{document}30 WBC, and 55/58 controls (sensitivity 94.4%, specificity 94.8%). The only false negative was paired to a traumatic LP with 40 corrected WBC/mm3.Conclusions:This non-invasive device could be an accurate tool for screening meningitis in neonates and young infants, modulating LP indications.ImpactOur non-invasive, high-resolution ultrasound device achieved 94% accuracy in detecting elevated leukocyte counts in neonates and infants with suspected meningitis, compared to the gold standard (lumbar punctures and laboratory analysis).This first-in-class screening device introduces the first non-invasive method for neonatal and infant meningitis screening, potentially modulating lumbar puncture indications.This technology could substantially reduce lumbar punctures in low-suspicion cases and provides a viable alternative critically ill patients worldwide or in settings where lumbar punctures are unfeasible, especially in low-income countries)., All authors with ISGlobal affiliation acknowledge support from the grant CEX2018- 000806-S funded by MCIN/AEI/ 10.13039/501100011033, and support from the Generalitat de Catalunya through the CERCA Program. In Mozambique and Morocco this work was supported, in whole or in part, by the Gates Foundation INV-048197. Under the grant conditions of the Foundation, a Creative Commons Attribution 4.0 Generic License has already been assigned to the Author Accepted Manuscript version that might arise from this submission. In Spain the study was funded by Project PI16/01822 from PI ENRIQUE BASSAT ORELLANA, funded by Instituto de Salud Carlos III and co-funded by the European Union (FEDER) “Una manera de hacer Europa”. In Morocco this study has been funded by the Spanish Agency of Cooperation (AECID) Grant number 2019/ACDE/001196. Its content is Sara Ajanovic et al’s responsibility and does not necessarily reflect AECID’s opinion. Kriba acknowledges support from the European Union’s Horizon Europe research and innovation program under project code 190155553 - NEOSONICS. Bill & Melinda Gates Foundation, Instituto de Salud Carlos III, European Union (FEDER), Spanish Agency of Cooperation (AECID), European Union’s Horizon Europe research and innovation., Peer reviewed