Publicación Artículo científico (JournalArticle)

Breaks invisible to the DNA damage response machinery accumulate in ATM-deficient cells

  • Martín Flix, Marta|||0000-0001-7849-3616
  • Terradas, Mariona|||0000-0001-7813-1172
  • Iliakis, George
  • Tusell Padrós, Laura|||0000-0002-2848-345X
  • Genescà, Anna|||0000-0002-0509-956X
After irradiation, ATM defective cells accumulate unrepaired double strand breaks (DSBs) for several cell divisions. At the chromosome level, unresolved DSBs appear as chromosome breaks that can be efficiently scored by using telomeric and mFISH probes. H2AX is immediately activated by ATM in response to DNA damage and its phosphorylated form, γH2AX, flanks the DSB through several megabases. The γH2AX-labeling status of broken chromosome ends was analyzed in AT cells to check whether the DNA damage response was accurately taking place in these persistent DSBs. The results show that one quarter of the scored breaks are devoid of γH2AX foci in metaphase spreads from ATM-deficient cells, and this fraction is significantly higher than in normal cells (χ2 < 0.05). Accumulation of sensor and repair proteins at damaged sites is a key event in the cellular response to DSBs, so MRE11 labeling at broken ends was also analyzed. While all γH2AX foci scored at visible broken ends colocalize with MRE11 foci, all γH2AX-unlabeled breaks are also devoid of MRE11-labeling. The present results suggest that a significant subset of the AT long-lived DSBs may persist as " invisible" DSBs due to deficient detection by the DNA damage repair machinery. Eventually the properly signaled DSBs will be repaired while invisible breaks may indefinitely accumulate; most probably contributing to the AT cells' well known genomic instability.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

FISH on sperm, spot-counting to stop counting? Not yet

  • Molina, Oscar|||0000-0001-7585-4519
  • Sarrate Navas, Zaida|||0000-0001-9677-1376
  • Vidal, Francesca|||0000-0002-0985-7348
  • Blanco, Joan|||0000-0003-0647-3856
Objective: To evaluate the reliability and applicability of the spot-counting system (Cytovision Spot AX workstation) which offers an alternative to the tedious manual analysis of sperm fluorescence in situ hybridization (FISH). Design: Manual and automatic analyses were performed and compared. Setting: Universitat Autònoma de Barcelona. Patient(s): Twenty-four men who asked for information on infertility showing different seminal parameters. Intervention(s): A semen sample for each patient was collected and prepared for FISH. Main Outcome Measure(s): A dual-color FISH using specific probes for chromosomes 13 and 21 and a triple-color FISH with centromeric probes for chromosomes 18, X, and Y were used (Vysis). Standard FISH analysis was carried out. Automatic analysis was subsequently performed using a Spot AX system. Result(s): Overall, we performed 120 comparisons. In 116 out of 120 (96.67%), the percentage of anomalies reported using manual counting fell within the incidence detected using the automatic system. In the remaining comparisons, statistical differences were detected (4 out of 120; 3.33%). Time consumed by the automatic analysis was always higher than the manual one, being influenced by the characteristics of the preparations. Conclusion(s): The spot-counting system has potential, but before the service is ready to be offered, we still need to overcome some limitations associated with it.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Fluorescence in situ hybridization (FISH) protocol in human sperm

  • Anton, Ester|||0000-0002-8914-2667
  • Sarrate Navas, Zaida|||0000-0001-9677-1376
Aneuploidies are the most frequent chromosomal abnormalities in humans. Most of these abnormalities result from meiotic errors during the gametogenic process in the parents. In human males, these errors can lead to the production of spermatozoa with numerical chromosome abnormalities which represent an increased risk of transmitting these anomalies to the offspring. For this reason, the technique of fluorescence in situ hybridization (FISH) on sperm nuclei has become a protocol widely incorporated in the context of clinical diagnosis. This practice provides an estimate of the frequencies of numerical chromosome abnormalities in the gametes of the patients that seek for genetic reproductive advice. To date, the chromosomes most frequently included in sperm FISH analysis are chromosomes X, Y, 13, 18 and 21. This video-article describes, step by step, how to process and fix a human semen sample, how to decondense and denature the sperm chromatin, how to proceed to obtain sperm FISH preparations, and how to visualize the results at the microscope. Special remarks of the most relevant steps are given to achieve the best results.