Publicación Artículo científico (JournalArticle)

Assessing the energetic and environmental impacts of the operation and maintenance of Spanish sewer networks from a life-cycle perspective

  • Petit-Boix, Anna|||0000-0003-2048-2708
  • Sanjuan Delmas, David|||0000-0002-5238-2069
  • Chenel, Sergio
  • Marín, Desirée
  • Martínez Gasol, Carles|||0000-0003-3002-9229
  • Farreny Gaya, Ramon
  • Villalba, Gara|||0000-0001-6392-0902
  • Suárez Ojeda, María Eugenia|||0000-0003-2520-2701
  • Gabarrell Durany, Xavier|||0000-0003-1730-4337
  • Josa Garcia-Tornel, Alejandro|||0000-0003-1180-7910
  • Rieradevall, Joan|||0000-0003-3360-6829
The environmental impacts resulting from sewer networks are best analysed from a life-cycle perspective to integrate the energy requirements into the infrastructure design. The energy requirements for pumping wastewater depend on the configuration of the city (e.g., climate, population, length of the sewer, topography, etc.). This study analyses and models the effect of such site-specific features on energy consumption and related effects in a sample of Spanish cities. The results show that the average annual energy used by sewers (6.4 kWh/capita and 0.014 kWh/m³ of water flow) must not be underestimated because they may require up to 50 % of the electricity needs of a typical treatment plant in terms of consumption per capita. In terms of Global Warming Potential, pumping results in an average of 2.3 kg CO₂eq./capita. A significant positive relationship was demonstrated between the kWh consumed and the length of the sewer and between other factors such as the population and wastewater production. In addition, Atlantic cities can consume 5 times as much energy as Mediterranean or Subtropical regions. A similar trend was shown in coastal cities. Finally, a simple predictive model of the electricity consumption was presented that considers the analysed parameters.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Environmental assessment of drinking water transport and distribution network use phase for small to medium-sized municipalities in Spain

  • Sanjuan Delmas, David|||0000-0002-5238-2069
  • Petit-Boix, Anna|||0000-0003-2048-2708
  • Martínez Gasol, Carles|||0000-0003-3002-9229
  • Farreny Gaya, Ramon
  • Villalba, Gara|||0000-0001-6392-0902
  • Suárez Ojeda, María Eugenia|||0000-0003-2520-2701
  • Gabarrell Durany, Xavier|||0000-0003-1730-4337
  • Josa Garcia-Tornel, Alejandro|||0000-0003-1180-7910
  • Rieradevall, Joan|||0000-0003-3360-6829
Previous studies assessing the environmental impacts of drinking water supply networks have considered a bottom-up approach, analysing single case studies. This paper presents a top-down approach for the assessment of the operational phase of a water supply network. A representative sample of 50 cities was statistically analysed to find relations between different variables regarding electricity and water consumption linked with the environmental impacts of the network. The results show that some of the variables are clearly related to the relative energy consumption of the network. Such is the case for population size, where small municipalities have up to 14 times higher relative electricity consumption compared with medium-sized municipalities (1.15E-2 as opposed to 8.3E-4 kWh/m³ registered water km of network) due to case-specific factors such as a strong gradient between a water tank and the consumption point. Similarly, the cases showing low population density exhibit 7 times higher relative electricity consumption because of the longer distances that must be covered and the correlation between population density and size. The values found for greenhouse gas (GHG) emissions derived from the energy consumption are consistent with results from previous studies: on average, 5.53 kg of CO₂ eq. emissions/inhabitant·year are released, but the variability is very high, ranging from 0.005 to 67.8 kg of CO₂ eq. emissions/inhabitant·year. No clearly significant correlations were found between the relative water demand and variables such as seasonality or income per capita, which might indicate that water consumption depends on individual decisions of the population rather than on the variables assessed. Models for the estimation of water demand, length of network and electricity consumption were defined. However, the modelling of electricity consumption presented more difficulties because of its high variability. A protocol for data collection should be defined and implemented in the future to enable the analysis of more high quality case studies and for the definition of more accurate and reliable models.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Environmental assessment of different pipelines for drinking water transport and distribution network in small to medium cities: a case from Betanzos, Spain, Environmental assessment of a drinking water transport and distribution network in small to medium cities and application to a case study network

  • Sanjuan Delmas, David|||0000-0002-5238-2069
  • Petit-Boix, Anna|||0000-0003-2048-2708
  • Martínez Gasol, Carles|||0000-0003-3002-9229
  • Villalba, Gara|||0000-0001-6392-0902
  • Suárez Ojeda, María Eugenia|||0000-0003-2520-2701
  • Gabarrell Durany, Xavier|||0000-0003-1730-4337
  • Josa Garcia-Tornel, Alejandro|||0000-0003-1180-7910
  • Rieradevall, Joan|||0000-0003-3360-6829
Until now, few studies had focused on the environmental impact of the construction phase of a drinking water transport and distribution network (DWTDN). Using the life cycle assessment (LCA) methodology, this article compares the environmental impact of pipes made of different materials as constructive solutions for the DWTDN. Two pipe diameters (90 and 200 mm) commonly used in small to medium-sized cities are analysed. The results show that polyvinyl chloride (PVC), high density polyethylene (HDPE) and low density PE have similar environmental impacts in the case of 90 mm pipe diameter. In the case of 200 mm pipe diameter, ductile iron (DI) and glass fibre reinforced polyester show higher environmental impacts than HDPE and PVC, which in the case of DI are between 3 and 11 times higher than those of HDPE for all the midpoint impact categories. Regarding the different construction phases, installation has a higher percentage of environmental impact for 90 mm pipe diameter (40-68% for HDPE in all the impact categories) than for 200 mm pipe diameter (24-57% for an HDPE) due to the difference in the amount of material required for the manufacture of the pipe. The assessment methodology was applied to calculate the environmental burdens derived from a case study. The impact of the different elements of the case study network has been added to obtain the global impact. The potential reduction of the environmental impacts of the case study has been calculated substituting the whole actual network by less impacting constructive solutions. A potential reduction of between 6 and 16% of the impact has been found for the case study, although the savings might be greater in networks with greater abundance of more impacting pipe materials such as DI. This methodology allows the improvement of the network and the design of more eco-efficient DWTDN.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Environmental assessment of sewer construction in small to medium sized cities using life cycle assessment

  • Petit-Boix, Anna|||0000-0003-2048-2708
  • Sanjuan Delmas, David|||0000-0002-5238-2069
  • Martínez Gasol, Carles|||0000-0003-3002-9229
  • Villalba, Gara|||0000-0001-6392-0902
  • Suárez Ojeda, María Eugenia|||0000-0003-2520-2701
  • Gabarrell Durany, Xavier|||0000-0003-1730-4337
  • Josa Garcia-Tornel, Alejandro|||0000-0003-1180-7910
  • Rieradevall, Joan|||0000-0003-3360-6829
In a world with an increasing urban population, analysing the construction impacts of sanitation infrastructures through Life Cycle Assessment (LCA) is necessary for defining the best environmental management strategies. In this study, the environmental impacts of one linear meter of sewer constructive solution were analysed for different pipe materials and diameters used in Southern Europe; a unit of different sewer appurtenances (pump, manhole and inspection chamber) was also considered. The impacts of the pipe materials were compared considering different lifespan periods and high-density polyethylene (HDPE) turned out to be the worst option, being polyvinyl chloride (PVC) and concrete the most favourable ones. Few data are available on the material and energy flows in the installation stage; therefore, a comparative analysis of trenches with sand and concrete bedding was conducted. The results show that the installation stage represents up to 80% of the total life-cycle impact of the constructive solutions. Concrete pipes with half-concrete/half-sand bedding are the best option and produce 20-30% of the impact of HDPE pipes with concrete bedding. Hence, designers should focus not only on the pipe but also on the trench model. A methodology was presented to enable the impact aggregation of the different sewer elements, and Betanzos (Spain) was selected to conduct a pilot study in small cities. In the future, studies will need to incorporate the use and maintenance stage, as it is not standard and varies according to the physical features of the cities. Finally, this study provides basic concepts for developing eco-efficiency indicators.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Environmental and geometric optimisation of cylindrical drinking water storage tanks

  • Sanjuan Delmas, David|||0000-0002-5238-2069
  • Gabarrell Durany, Xavier|||0000-0003-1730-4337
  • Rieradevall, Joan|||0000-0003-3360-6829
  • Hernando-Canovas, Elena
  • Pujadas Álvarez, Pablo|||0000-0001-5634-7431
  • Fuente Antequera, Albert de la|||0000-0002-8016-1677
  • Josa Garcia-Tornel, Alejandro|||0000-0003-1180-7910
Purpose: Urban water cycle construction processes are an important element to consider when assessing the sustainability of urban areas. The present study focuses on a structural and environmental analysis of cylindrical water tanks. The goal is to optimise cylindrical water tanks from both an environmental (environmental impacts due of life cycle assessment (LCA)) and a geometric perspective (building material quantities for construction purposes depending on the tank characteristics). Methods: A sample of 147 cases was defined based on different positions (buried, superficial and partially buried), dimensions (combinations of heights and radii) and storage capacities (between 100 and 10,000 m3). A structural analysis was conducted for a defined set of cases to determine the quantities of steel and concrete required for its construction. The environmental impacts of the entire life cycle were assessed through a life cycle assessment (LCA). Additionally, environmental standards (the less impactful option for each dimension assessed: geometry, storage capacity and position) defined in the study were applied to realistic cases to evaluate potential environmental savings. Results and discussion: The LCA shows that materials are the main contributor to environmental impacts (more than transport, installation and end of life cycle stages). For this reason, the results of the structural and environmental assessments coincide. Taller water tanks have shown to be less impactful (60 to 70 % less impact for a 10.000-m3 tank). Regarding the position, superficial water tanks have shown to have between 15 and 35 % less impact than buried ones. The environmentally preferred water storage capacity is between 1000 and 2500 m3, being between 20 and 40 % less impact. For instance, an 8000-m3 tank would emit 1040 t of CO2 eq. Applying the environmental standards 170.5 t of CO2 eq could be saved (16 % of the total amount). Conclusions: The results of this study show that among the cases analysed, superficially positioned cylindrical water tanks of 8.5 m in height and of between 1000 and 2500 m3 in storage capacity present fewer impacts. The use of these standards in municipal water tanks construction projects may significantly reduce environmental impacts (10 to 40 %) in all impact categories.