Evaluation of Respiratory Muscle Activity by Means of Concentric Ring Electrodes
[EN] Surface electromyography (sEMG) can be used for the evaluation of respiratory muscle activity. Recording sEMG involves the use of surface electrodes in a bipolar configuration. However, electrocardiographic (ECG) interference and electrode orientation represent considerable drawbacks to bipolar acquisition. As an alternative, concentric ring electrodes (CREs) can be used for sEMG acquisition and offer great potential for the evaluation of respiratory muscle activity due to their enhanced spatial resolution and simple placement protocol, which does not depend on muscle fiber orientation. The aim of this work was to analyze the performance of CREs during respiratory sEMG acquisitions. Respiratory muscle sEMG was applied to the diaphragm and sternocleidomastoid muscles using a bipolar and a CRE configuration. Thirty-two subjects underwent four inspiratory load spontaneous breathing tests which was repeated after interchanging the electrode positions. We calculated parameters such as (1) spectral power and (2) median frequency during inspiration, and power ratios of inspiratory sEMG without ECG in relation to (3) basal sEMG without ECG (R-ins/noise), (4) basal sEMG with ECG (R-ins/cardio) and (5) expiratory sEMG without ECG (R-ins/exp). Spectral power, R-ins/noise and R-ins/cardio increased with the inspiratory load. Significantly higher values (p < 0.05) of R-ins/cardio and significantly higher median frequencies were obtained for CREs. R-ins/noise and R-ins/exp were higher for the bipolar configuration only in diaphragm sEMG recordings, whereas no significant differences were found in the sternocleidomastoid recordings. Our results suggest that the evaluation of respiratory muscle activity by means of sEMG can benefit from the remarkably reduced influence of cardiac activity, the enhanced detection of the shift in frequency content and the axial isotropy of CREs which facilitates its placement., This work was supported in part by the CERCA Program/Generalitat de Catalunya, in part by the Secretaria d'Universitats i Recerca de la Generalitat de Catalunya under Grant GRC 2017 SGR 01770, in part by the Spanish Grants RTI2018-098472-B-I00, RTI2018-094449-A-I00-AR (MCIU/AEI/FEDER, UE) and DPI2015-68397-R (MINECO/FEDER), and in part by the Biomedical Research Networking Centre in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN, Instituto de Salud Carlos III/FEDER). The first author was supported by the IFARHU-SENACYT Scholarship Program from the Panama Government under Grant 270-2012-273.
Proyecto:
Agencia Estatal de Investigación / Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020 RTI2018-094449-A-I00
,
Generalitat de Catalunya / Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020 2017 SGR 01770
,
Agencia Estatal de Investigación RTI2018-098472-B-I00
,
Secretaría Nacional de Ciencia 270-2012-273
,
Tecnología e Innovación DPI2015-68397-R