ECOSISTEMA DE SALUD INTELIGENTE (HERRAMIENTAS-APPS-DISPOSITIVOS) PARA LA MEDICINA PERSONALIZADA Y LA ASISTENCIA SANITARIA EN ENFERMEDADES RESPIRATORIAS Y TRASTORNOS DEL SUEÑO

RTI2018-098472-B-I00

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos I+D+i Retos de Investigación
Año convocatoria 2018
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario FUNDACIO INSTITUT DE BIOENGINYERIA DE CATALUNYA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 6
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Evaluation of Respiratory Muscle Activity by Means of Concentric Ring Electrodes

  • Estrada-Petrocelli, Luis
  • Torres, Abel
  • Sarlabous, Leonardo
  • Ràfols-de-Urquía, Magda
  • Jané, Raimon
  • Ye Lin, Yiyao|||0000-0003-2929-181X
  • Prats-Boluda, Gema|||0000-0002-9362-5055
  • Garcia-Casado, Javier|||0000-0003-1410-2721
[EN] Surface electromyography (sEMG) can be used for the evaluation of respiratory muscle activity. Recording sEMG involves the use of surface electrodes in a bipolar configuration. However, electrocardiographic (ECG) interference and electrode orientation represent considerable drawbacks to bipolar acquisition. As an alternative, concentric ring electrodes (CREs) can be used for sEMG acquisition and offer great potential for the evaluation of respiratory muscle activity due to their enhanced spatial resolution and simple placement protocol, which does not depend on muscle fiber orientation. The aim of this work was to analyze the performance of CREs during respiratory sEMG acquisitions. Respiratory muscle sEMG was applied to the diaphragm and sternocleidomastoid muscles using a bipolar and a CRE configuration. Thirty-two subjects underwent four inspiratory load spontaneous breathing tests which was repeated after interchanging the electrode positions. We calculated parameters such as (1) spectral power and (2) median frequency during inspiration, and power ratios of inspiratory sEMG without ECG in relation to (3) basal sEMG without ECG (R-ins/noise), (4) basal sEMG with ECG (R-ins/cardio) and (5) expiratory sEMG without ECG (R-ins/exp). Spectral power, R-ins/noise and R-ins/cardio increased with the inspiratory load. Significantly higher values (p < 0.05) of R-ins/cardio and significantly higher median frequencies were obtained for CREs. R-ins/noise and R-ins/exp were higher for the bipolar configuration only in diaphragm sEMG recordings, whereas no significant differences were found in the sternocleidomastoid recordings. Our results suggest that the evaluation of respiratory muscle activity by means of sEMG can benefit from the remarkably reduced influence of cardiac activity, the enhanced detection of the shift in frequency content and the axial isotropy of CREs which facilitates its placement., This work was supported in part by the CERCA Program/Generalitat de Catalunya, in part by the Secretaria d'Universitats i Recerca de la Generalitat de Catalunya under Grant GRC 2017 SGR 01770, in part by the Spanish Grants RTI2018-098472-B-I00, RTI2018-094449-A-I00-AR (MCIU/AEI/FEDER, UE) and DPI2015-68397-R (MINECO/FEDER), and in part by the Biomedical Research Networking Centre in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN, Instituto de Salud Carlos III/FEDER). The first author was supported by the IFARHU-SENACYT Scholarship Program from the Panama Government under Grant 270-2012-273.
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

The effect of walking on the estimation of breathing pattern parameters using wearable bioimpedance

  • Blanco Almazán, María Dolores|||0000-0002-8532-5394
  • Groenendaal, Willemijn
  • Catthoor, Francky
  • Jané Campos, Raimon|||0000-0002-6541-8729
© 2022 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works., Wearable bioimpedance is a technique proposed to estimate breathing parameters such as respiratory rate (RR). However, its potential application lies in clinical investigation of daily-life activities like walking. This study evaluated the effect of the walking interference on the estimation of breathing parameters. 50 chronic obstructive pulmonary disease patients performed static and active measurements during thoracic bioimpedance acquisition. The static measurements included respiratory airflow for reference. The active measurements were used to estimate the walking interference from bioimpedance, and the obtained signals were added to static measurements for comparison with the reference. Afterward, we applied four different preprocessing methods to remove this walking interference and the resulting signals were used to detect the respiratory cycles and estimate breathing parameters (inspiratory time, expiratory time, duty cycle, and RR). The methods performed differently in terms of accuracy and mean average percentage error (MAPE), showing the need for specific preprocessing for active measurements. Furthermore, the MAPE values in the RR estimation were close to 3 % indicating that breathing parameters can be accurately estimated during walking. Accordingly, the present study reinforces the applicability of wearable bioimpedance for respiratory monitoring. Clinical relevance- This study exhibits the suitability of wearable bioimpedance to estimate accurate breathing param-eters during walking activities., This work was supported in part by the Universities and Research Secretariat from the Generalitat de Catalunya under Grant GRC 2017 SGR 01770 and, GrantFI-DGR, in part by the Agencia Estatal de Investigación from the Spanish Ministry of Science, Innovation and Universities and the European Regional Development Fund, under the Grant RTI 2018 098472B-I00, and in part by the CERCA Programme/Generalitat de Catalunya., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Breathing pattern estimation using wearable bioimpedance for assessing COPD severity

  • Blanco Almazán, María Dolores|||0000-0002-8532-5394
  • Groenendaal, Willemijn
  • Lijnen, Lien
  • Önder, Rana
  • Smeets, Christophe
  • Ruttens, David
  • Catthoor, Francky
  • Jané Campos, Raimon|||0000-0002-6541-8729
Breathing pattern has been shown to be different in chronic obstructive pulmonary disease (COPD) patients compared to healthy controls during rest and walking. In this study we evaluated respiratory parameters and the breathing variability of COPD patients as a function of their severity. Thoracic bioimpedance was acquired on 66 COPD patients during the performance of the six-minute walk test (6MWT), as well as 5 minutes before and after the test while the patients were seated, i.e. resting and recovery phases. The patients were classified by their level of airflow limitation into moderate and severe groups. We characterized the breathing patterns by evaluating common respiratory parameters using only wearable bioimpedance. Specifically, we computed the median and the coefficient of variation of the parameters during the three phases of the protocol, and evaluated the statistical differences between the two COPD severity groups. We observed significant differences between the COPD severity groups only during the sitting phases, whereas the behavior during the 6MWT was similar. Particularly, we observed an inverse relationship between breathing pattern variability and COPD severity, which may indicate that the most severely diseased patients had a more restricted breathing compared to the moderate patients., This work was supported in part by the Universities and Research Secretariat from the Ministry of Business and Knowledge/Generalitat de Catalunya under the Grant GRC 2017 SGR 01770, in part by the Agencia Estatal de Investigacion from the Spanish Ministry of Science ánd Innovation and the European Regional Development Fund, under the Grants RTI2018 098472-B-I00 and PID2021-126455OB-I00, and in part by the CERCA Programme/Generalitat de Catalunya., Peer Reviewed
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Breathing pattern estimation using wearable bioimpedance for assessing COPD severity

  • Blanco Almazán, María Dolores
  • Groenendaal, Willemijn
  • Lijnen, Lien
  • Önder, Rana
  • Smeets, Christophe
  • Ruttens, David
  • Catthoor, Francky
  • Jané Campos, Raimon
Breathing pattern has been shown to be different in chronic obstructive pulmonary disease (COPD) patients compared to healthy controls during rest and walking. In this study we evaluated respiratory parameters and the breathing variability of COPD patients as a function of their severity. Thoracic bioimpedance was acquired on 66 COPD patients during the performance of the six-minute walk test (6MWT), as well as 5 minutes before and after the test while the patients were seated, i.e. resting and recovery phases. The patients were classified by their level of airflow limitation into moderate and severe groups. We characterized the breathing patterns by evaluating common respiratory parameters using only wearable bioimpedance. Specifically, we computed the median and the coefficient of variation of the parameters during the three phases of the protocol, and evaluated the statistical differences between the two COPD severity groups. We observed significant differences between the COPD severity groups only during the sitting phases, whereas the behavior during the 6MWT was similar. Particularly, we observed an inverse relationship between breathing pattern variability and COPD severity, which may indicate that the most severely diseased patients had a more restricted breathing compared to the moderate patients., This work was supported in part by the Universities and Research Secretariat from the Ministry of Business and Knowledge/Generalitat de Catalunya under the Grant GRC 2017 SGR 01770, in part by the Agencia Estatal de Investigacion from the Spanish Ministry of Science ánd Innovation and the European Regional Development Fund, under the Grants RTI2018 098472-B-I00 and PID2021-126455OB-I00, and in part by the CERCA Programme/Generalitat de Catalunya., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

The effect of walking on the estimation of breathing pattern parameters using wearable bioimpedance

  • Blanco Almazán, María Dolores
  • Groenendaal, Willemijn
  • Catthoor, Francky
  • Jané Campos, Raimon
© 2022 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works., Wearable bioimpedance is a technique proposed to estimate breathing parameters such as respiratory rate (RR). However, its potential application lies in clinical investigation of daily-life activities like walking. This study evaluated the effect of the walking interference on the estimation of breathing parameters. 50 chronic obstructive pulmonary disease patients performed static and active measurements during thoracic bioimpedance acquisition. The static measurements included respiratory airflow for reference. The active measurements were used to estimate the walking interference from bioimpedance, and the obtained signals were added to static measurements for comparison with the reference. Afterward, we applied four different preprocessing methods to remove this walking interference and the resulting signals were used to detect the respiratory cycles and estimate breathing parameters (inspiratory time, expiratory time, duty cycle, and RR). The methods performed differently in terms of accuracy and mean average percentage error (MAPE), showing the need for specific preprocessing for active measurements. Furthermore, the MAPE values in the RR estimation were close to 3 % indicating that breathing parameters can be accurately estimated during walking. Accordingly, the present study reinforces the applicability of wearable bioimpedance for respiratory monitoring. Clinical relevance- This study exhibits the suitability of wearable bioimpedance to estimate accurate breathing param-eters during walking activities., This work was supported in part by the Universities and Research Secretariat from the Generalitat de Catalunya under Grant GRC 2017 SGR 01770 and, GrantFI-DGR, in part by the Agencia Estatal de Investigación from the Spanish Ministry of Science, Innovation and Universities and the European Regional Development Fund, under the Grant RTI 2018 098472B-I00, and in part by the CERCA Programme/Generalitat de Catalunya., Peer Reviewed, Postprint (author's final draft)
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Detection of Sleep-Disordered Breathing in Patients with Spinal Cord Injury Using a Smartphone

  • Castillo-Escario, Yolanda|||0000-0002-7493-1268
  • Kumru, Hatice|||0000-0002-0501-1660
  • Ferrer-Lluis, Ignasi|||0000-0002-0281-9023
  • Vidal, Joan|||0000-0002-3952-2442
  • Jané Campos, Raimon|||0000-0002-6541-8729
Patients with spinal cord injury (SCI) have an increased risk of sleep-disordered breathing (SDB), which can lead to serious comorbidities and impact patients' recovery and quality of life. However, sleep tests are rarely performed on SCI patients, given their multiple health needs and the cost and complexity of diagnostic equipment. The objective of this study was to use a novel smartphone system as a simple non-invasive tool to monitor SDB in SCI patients. We recorded pulse oximetry, acoustic, and accelerometer data using a smartphone during overnight tests in 19 SCI patients and 19 able-bodied controls. Then, we analyzed these signals with automatic algorithms to detect desaturation, apnea, and hypopnea events and monitor sleep position. The apnea-hypopnea index (AHI) was significantly higher in SCI patients than controls (25 ± 15 vs. 9 ± 7, p < 0.001). We found that 63% of SCI patients had moderate-to-severe SDB (AHI ≥ 15) in contrast to 21% of control subjects. Most SCI patients slept predominantly in supine position, but an increased occurrence of events in supine position was only observed for eight patients. This study highlights the problem of SDB in SCI and provides simple cost-effective sleep monitoring tools to facilitate the detection, understanding, and management of SDB in SCI patients.