Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 8
Encontrada(s) 1 página(s)

DAU Arxiu Digital de la Universitat Ramon Llull
Publicación Artículo científico (JournalArticle)

Life Cycle Assessment of the Separation and Recycling of Fluorinated Gases Using Ionic Liquids in a Circular Economy FrameworkClick to copy article link

  • Jovell, Daniel
  • Pou, Josep Oriol
  • Llovell Ferret, Félix Lluís
  • González Olmos, Rafael
The stricter regulation regarding the use of fluorinated gases (F-gases), as a consequence of their high Global Warming Potential (GWP), represents a challenge for the refrigeration industry. The design of alternatives requires the recycling of the low to moderate GWP compounds from current refrigerant blends. However, there is not a developed and standardized technology available to recover them, and once the life cycle of the refrigeration equipment has ended, most gases are incinerated. Fluorinated ionic liquids (FILs) can effectively perform as absorbents to the complex separation of F-gas mixtures. In this work, a methodology based on the COSMO-RS thermodynamic package integrated into an Aspen Plus process simulator was used to evaluate the performance of an FIL to recover difluoromethane (R-32) from the commercial blend R-407F. The environmental sustainability of the recovery process (circular economy scenario) was analyzed with a life cycle assessment (LCA) approach, comparing the obtained results with the conventional R-32 production (benchmark scenario). The results reveal a 30% recovery of 98 wt % R-32 suitable for further reuse with environmental load reduction in the 86–99% range compared to the R-32 production. This study can guide the development of new F-gas recovery technologies to improve the environmental impacts of these compounds from a circular economy perspective., info:eu-repo/semantics/publishedVersion
DAU Arxiu Digital de la Universitat Ramon Llull
Publicación Artículo científico (JournalArticle)

Combining biological processes with UV/H2O2 for metoprolol and metoprolol acid removal in hospital wastewater

  • Jaén-Gil, Adrián
  • Buttiglieri, Gianluigi
  • Benito, Aleix
  • Mir Tutusaus, Josep Anton
  • González Olmos, Rafael
  • Caminal, Gloria
  • Barceló, Damià
  • Sarrà, Montserrat
  • Rodriguez-Mozaz, Sara
The transformation products (TPs) of water contaminants generated during wastewater treatment can sometimes be equally or even more hazardous than the parent compounds. Therefore, for a comprehensive assessment of removal efficiency of a water treatment technology, it is mandatory to monitor not only the pollutants but also of their TPs. However, this type of evaluation studies is lacking in the case of water combined treatments. In this study, the elimination of metoprolol (MTP), metoprolol acid (MTPA) and the TPs generated was evaluated in pure water and hospital wastewater (HWW) using UV/H2O2 before and after fungal (FG) or conventional activated sludge (CAS). The major transformation pathways were suggested in terms of transformation of the parent compounds through bio-transformation and photo-transformation mechanisms. The results reveal an extended removal of MTP, MTPA and TPs after UV/H2O2 single experiment treating spiked pure water at 2.5 mg/L, without increasing the treated effluents toxicity. However, combined treatments were required to achieve similar removal percentages in spiked real HWW at 2.0 μg/L: while AOPs combined with FG exhibited lower removal efficiencies with generation of persistent intermediates (such as α-HMTP and TP240), AOPs combined with CAS attained the higher persistent TPs removal. In particular, AOP + CAS was classified as the most effective combination for HWW with the highest removal of the parent compounds (86% for MTP and 100% for MTPA), of the intermediates generated (up to 85%) and with a low presence of toxic TPs (such as O-DMTP). This study demonstrates that comprehensive evaluation of the intermediates generated along water treatment technologies is highly recommended to successfully evaluate their removal efficiencies., info:eu-repo/semantics/publishedVersion
DAU Arxiu Digital de la Universitat Ramon Llull
Publicación Artículo científico (JournalArticle)

A computational drop-in assessment of hydrofluoroethers in Organic Rankine Cycles

  • Jovell, Daniel
  • González Olmos, Rafael
  • Llovell Ferret, Félix Lluís
Organic Rankine Cycles (ORCs) are experiencing a growing interest due to their ability to generate electricity from residual low waste heat sources. HFC-245fa is a representative working fluid for ORC applications, but it has recently been phased-out in new equipment because of its high global warming potential (GWP). In this work, the soft-SAFT molecular-based equation of state is used to evaluate the capacity of nine promising low-GWP hydrofluoroethers (HFEs) as alternative working fluids in ORC applications using different key performance indicators focused on energy efficiency and service fluids consumption. The thermodynamic model has been employed to characterize these fluids by describing saturated densities, vapor pressure, surface tension, temperature-enthalpy, and temperature-entropy diagrams, including further validation with binary mixtures. Then, based on technical criteria focused on the thermal efficiency and working and service fluids consumption, the soft-SAFT model has been used to conduct a feasibility study of HFEs as direct substitutes for HFC-245fa in such applications. Although pure fluids can not reach the same efficiency as the benchmark, HFE-356mmz, HFE-7000, and HFE-7100 appear as promising replacements, capable of approaching system requirements operating at low pressure with low cooling water and heating fluid flow rates, while exhibiting lower GWP values., info:eu-repo/semantics/publishedVersion
DAU Arxiu Digital de la Universitat Ramon Llull
Publicación Artículo científico (JournalArticle)

A consistent thermodynamic molecular model of n-hydrofluoroolefins and blends for refrigeration applications, Modèle moléculaire thermodynamique cohérent des n-hydrofluoroléfines et de leurs mélanges pour des applications dans le domaine du froid

  • Llovell Ferret, Félix Lluís
  • Albà, Carlos G.
  • Vega, Lourdes F.
This work presents a thermodynamic model that characterizes 4th-generation hydrofluoroolefins (HFOs)-based refrigerants with the molecular-based soft-SAFT equation of state (Blas and Vega, 1998) as well as its application in process simulations for a selected refrigeration application. The evaluation of the HFOs has been done building on a molecular model transferred from the equivalent hydrofluorocarbons (HFCs), taking advantage of the similarities between the two chemical families. The model has been used to calculate all thermophysical properties of the selected HFOs relevant for their application as refrigerants, including the saturated density, vapor pressure, heat capacity, speed of sound, surface tension and viscosity, providing good agreement with experimental available data. In addition, phase equilibria, interfacial behavior and viscosity calculations have been performed for blends between HFCs and the two most common HFOs, R1234yf and R1234ze(E). The obtained thermodynamic properties have been used for a process simulation of a vapor compression refrigeration system, comparing the 3rd generation refrigerant R410A with these 4th generation blends, including the Coefficient of Performance for different cases, in order to establish the best alternative to R410A. Overall, this work shows how molecular modeling tools can be used now a day, as a complementary tool to generate reliable data for process simulation, in this case related to the search for alternative refrigerants.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Life Cycle Assessment of the Separation and Recycling of Fluorinated Gases Using Ionic Liquids in a Circular Economy FrameworkClick to copy article link

  • Jovell, Daniel
  • Pou, Josep Oriol
  • Llovell Ferret, Félix Lluís
  • González Olmos, Rafael
The stricter regulation regarding the use of fluorinated gases (F-gases), as a consequence of their high Global Warming Potential (GWP), represents a challenge for the refrigeration industry. The design of alternatives requires the recycling of the low to moderate GWP compounds from current refrigerant blends. However, there is not a developed and standardized technology available to recover them, and once the life cycle of the refrigeration equipment has ended, most gases are incinerated. Fluorinated ionic liquids (FILs) can effectively perform as absorbents to the complex separation of F-gas mixtures. In this work, a methodology based on the COSMO-RS thermodynamic package integrated into an Aspen Plus process simulator was used to evaluate the performance of an FIL to recover difluoromethane (R-32) from the commercial blend R-407F. The environmental sustainability of the recovery process (circular economy scenario) was analyzed with a life cycle assessment (LCA) approach, comparing the obtained results with the conventional R-32 production (benchmark scenario). The results reveal a 30% recovery of 98 wt % R-32 suitable for further reuse with environmental load reduction in the 86–99% range compared to the R-32 production. This study can guide the development of new F-gas recovery technologies to improve the environmental impacts of these compounds from a circular economy perspective., info:eu-repo/semantics/publishedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Combining biological processes with UV/H2O2 for metoprolol and metoprolol acid removal in hospital wastewater

  • Jaén-Gil, Adrián
  • Buttiglieri, Gianluigi
  • Benito, Aleix
  • Mir Tutusaus, Josep Anton
  • González Olmos, Rafael
  • Caminal, Gloria
  • Barceló, Damià
  • Sarrà, Montserrat
  • Rodriguez-Mozaz, Sara
The transformation products (TPs) of water contaminants generated during wastewater treatment can sometimes be equally or even more hazardous than the parent compounds. Therefore, for a comprehensive assessment of removal efficiency of a water treatment technology, it is mandatory to monitor not only the pollutants but also of their TPs. However, this type of evaluation studies is lacking in the case of water combined treatments. In this study, the elimination of metoprolol (MTP), metoprolol acid (MTPA) and the TPs generated was evaluated in pure water and hospital wastewater (HWW) using UV/H2O2 before and after fungal (FG) or conventional activated sludge (CAS). The major transformation pathways were suggested in terms of transformation of the parent compounds through bio-transformation and photo-transformation mechanisms. The results reveal an extended removal of MTP, MTPA and TPs after UV/H2O2 single experiment treating spiked pure water at 2.5 mg/L, without increasing the treated effluents toxicity. However, combined treatments were required to achieve similar removal percentages in spiked real HWW at 2.0 μg/L: while AOPs combined with FG exhibited lower removal efficiencies with generation of persistent intermediates (such as α-HMTP and TP240), AOPs combined with CAS attained the higher persistent TPs removal. In particular, AOP + CAS was classified as the most effective combination for HWW with the highest removal of the parent compounds (86% for MTP and 100% for MTPA), of the intermediates generated (up to 85%) and with a low presence of toxic TPs (such as O-DMTP). This study demonstrates that comprehensive evaluation of the intermediates generated along water treatment technologies is highly recommended to successfully evaluate their removal efficiencies., info:eu-repo/semantics/publishedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

A computational drop-in assessment of hydrofluoroethers in Organic Rankine Cycles

  • Jovell, Daniel
  • González Olmos, Rafael
  • Llovell Ferret, Félix Lluís
Organic Rankine Cycles (ORCs) are experiencing a growing interest due to their ability to generate electricity from residual low waste heat sources. HFC-245fa is a representative working fluid for ORC applications, but it has recently been phased-out in new equipment because of its high global warming potential (GWP). In this work, the soft-SAFT molecular-based equation of state is used to evaluate the capacity of nine promising low-GWP hydrofluoroethers (HFEs) as alternative working fluids in ORC applications using different key performance indicators focused on energy efficiency and service fluids consumption. The thermodynamic model has been employed to characterize these fluids by describing saturated densities, vapor pressure, surface tension, temperature-enthalpy, and temperature-entropy diagrams, including further validation with binary mixtures. Then, based on technical criteria focused on the thermal efficiency and working and service fluids consumption, the soft-SAFT model has been used to conduct a feasibility study of HFEs as direct substitutes for HFC-245fa in such applications. Although pure fluids can not reach the same efficiency as the benchmark, HFE-356mmz, HFE-7000, and HFE-7100 appear as promising replacements, capable of approaching system requirements operating at low pressure with low cooling water and heating fluid flow rates, while exhibiting lower GWP values., info:eu-repo/semantics/publishedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

A consistent thermodynamic molecular model of n-hydrofluoroolefins and blends for refrigeration applications, Modèle moléculaire thermodynamique cohérent des n-hydrofluoroléfines et de leurs mélanges pour des applications dans le domaine du froid

  • Llovell Ferret, Félix Lluís
  • Albà, Carlos G.
  • Vega, Lourdes F.
This work presents a thermodynamic model that characterizes 4th-generation hydrofluoroolefins (HFOs)-based refrigerants with the molecular-based soft-SAFT equation of state (Blas and Vega, 1998) as well as its application in process simulations for a selected refrigeration application. The evaluation of the HFOs has been done building on a molecular model transferred from the equivalent hydrofluorocarbons (HFCs), taking advantage of the similarities between the two chemical families. The model has been used to calculate all thermophysical properties of the selected HFOs relevant for their application as refrigerants, including the saturated density, vapor pressure, heat capacity, speed of sound, surface tension and viscosity, providing good agreement with experimental available data. In addition, phase equilibria, interfacial behavior and viscosity calculations have been performed for blends between HFCs and the two most common HFOs, R1234yf and R1234ze(E). The obtained thermodynamic properties have been used for a process simulation of a vapor compression refrigeration system, comparing the 3rd generation refrigerant R410A with these 4th generation blends, including the Coefficient of Performance for different cases, in order to establish the best alternative to R410A. Overall, this work shows how molecular modeling tools can be used now a day, as a complementary tool to generate reliable data for process simulation, in this case related to the search for alternative refrigerants.