Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Synchronization study of electrohysterography for discrimination of imminent delivery in pregnant women with threatened preterm labor

  • Li, Wanting
  • Yang, Yongxiu
  • Li, Guangfei
  • Hao, Dongmei
  • Nieto del-Amor, Félix|||0000-0003-0050-9360
  • Prats-Boluda, Gema|||0000-0002-9362-5055
  • Garcia-Casado, Javier|||0000-0003-1410-2721
  • Ye Lin, Yiyao|||0000-0003-2929-181X
[EN] Preterm birth a common and severe pregnancy complications, causing significant health, development, and economic problems. Accurate diagnosis of imminent labor for women with threatened preterm labor (TPL) is crucial. Electrohysterography (EHG), which represents uterine myometrial electrical activity, is a potential tool for predicting preterm birth. Increased cell synchronization is fundamental to generating high-intensity and coordinated uterine myometrial electrical activity as labor approaches. The present work aimed to evaluate the synchronization measures from multichannel EHG signals to predict labor in less than 24 h (time to delivery, TTD <24 h vs. TTD¿24 h), and between imminent labor (TTD <1 week) and non-imminent labor (TTD¿1 week) in women with TPL. We computed three synchronization measures: the imaginary component of coherence, phase lag index, and weighted phase lag index (wPLI) within three specific frequency bandwidths (fast wave low (FWL): 0.1¿0.34 Hz, fast wave high (FWH): 0.34¿1 Hz, and whole bandwidth: 0.1¿1 Hz) from 115 pregnant women (26¿41 weeks of gestation). Our results revealed that multichannel EHG synchronization measures significantly increased closer to delivery (labor > non-labor, imminent > non-imminent). Indeed, wPLI in the FWH bandwidth exhibited a positive correlation with gestational age (p < 0.001¿correlation coefficient = 0.35) and an inverse relationship with time to delivery (p < 0.001¿correlation coefficient = ¿0.33). wPLI allows for better distinguishing imminent from non-imminent in women with TPL, especially for those electrode pairs in the vertical direction, which has been reported as the predominant direction of uterine activity propagation. The three synchronization measures computed in FWL and FWH bandwidth provided complementary information for predicting labor in less than 24 h and also imminent labor in women with TPL, achieving an F1-score of 93 % (84.2¿93 %) and 99.5 % (85.2¿99.5 %) respectively. Our results suggest that EHG synchronization analysis constitutes a new sensitive metrics to discriminate imminent labor which can be potentially used for improving preterm birth prediction and understand uterine electrical activity dynamics., This research was funded by National Natural Science Foundation of China (U20A20388), the National Key R&D Program (2019YFC0119700), and by the Spanish Ministry of Science and Innovation and the European Regional Development Fund, State Plan for Scientific, Technical and Innovation Research 2021 2023 (PID2021-124038OB-I00).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Assessment of Features between Multichannel Electrohysterogram for Differentiation of Labors

  • Zhang, Yajun
  • Hao, Dongmei
  • Yang, Lin
  • Zhou, Xiya
  • Yang, Yimin
  • Ye Lin, Yiyao|||0000-0003-2929-181X
[EN] Electrohysterogram (EHG) is a promising method for noninvasive monitoring of uterine electrical activity. The main purpose of this study was to characterize the multichannel EHG signals to distinguish between term delivery and preterm birth, as well as deliveries within and beyond 24 h. A total of 219 pregnant women were grouped in two ways: (1) term delivery (TD), threatened preterm labor (TPL) with the outcome of preterm birth (TPL_PB), and TPL with the outcome of term delivery (TPL_TD); (2) EHG recording time to delivery (TTD) <= 24 h and TTD > 24 h. Three bipolar EHG signals were analyzed for the 30 min recording. Six EHG features between multiple channels, including multivariate sample entropy, mutual information, correlation coefficient, coherence, direct partial Granger causality, and direct transfer entropy, were extracted to characterize the coupling and information flow between channels. Significant differences were found for these six features between TPL and TD, and between TTD <= 24 h and TTD > 24 h. No significant difference was found between TPL_PB and TPL_TD. The results indicated that EHG signals of TD were more regular and synchronized than TPL, and stronger coupling between multichannel EHG signals was exhibited as delivery approaches. In addition, EHG signals propagate downward for the majority of pregnant women regardless of different labors. In conclusion, the coupling and propagation features extracted from multichannel EHG signals could be used to differentiate term delivery and preterm birth and may predict delivery within and beyond 24 h., This research was funded by the National Key R&D Program, grant number 2019YFC0119700, and the National Natural Science Foundation of China, grant number U20A20388.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Recurrence quantification analysis of uterine vectormyometriogram to identify pregnant women with threatened preterm labor

  • Nieto del-Amor, Félix|||0000-0003-0050-9360
  • Prats-Boluda, Gema|||0000-0002-9362-5055
  • Martínez-de-Juan, José L.|||0000-0001-9133-3123
  • Ye Lin, Yiyao|||0000-0003-2929-181X
  • Li, Wanting
  • Yang, Lin
  • Yang, Yongxiu
  • Hao, Dongmei
[EN] Electrohysterography has been shown to provide relevant information on preventing preterm labor. Recent studies have confirmed the feasibility of using the vectormyometriogram (VMG) to assess uterine myoelectric vector displacement, with different physiological implications for the slow and fast waves, without suggesting its implementation in clinical practice. The fast wave VMG component has dynamic behavior in any specific direction on the X-Y plane. Since recurrence is a common feature of dynamic systems, we aimed to determine the recurrence pattern of uterine vector displacement, exploring its clinical potential in detecting imminent and preterm labor in women with threatened preterm labor and a serious preterm birth risk. For this, we analyzed the recurrence patterns from a 2D-vectormyometriogram using four common statistics: determinism, longest diagonal, entropy, and laminarity. We found significantly increased determinism (0.035 ± 0.011 vs. 0.077 ± 0.041), entropy (1.768 ± 0.116 vs. 2.197 ± 0.24) and laminarity (0.086 ± 0.034 vs. 0.173 ± 0.078) from the early (26¿30 weeks) to late (35¿37 weeks) gestation stages. As pregnancy progresses, the uterine vector displacement becomes more periodic, predictable and stable, while VMG recurrence statistics in the fast wave high bandwidth better detect imminent and preterm labor, outperforming classical EHG parameters from bipolar channels. The proposed method was also resistant to motion artifacts and preserved its discriminative capacity between the groups. Our results on VMG recurrence statistics could thus be another reliable biomarker for preventing preterm labor in women with threatened preterm labor and would favor transferring the EHG technique to clinical practice., This work was supported by the Spanish Ministry of Science and Innovation and the European Regional Development Fund, State Plan for Scientific, Technical and Innovation Research 2021 - 2023 (PID2021-124038OB-I00) . This research was funded by the National Key R & D Program, grant number 2019YFC0119700, and the National Natural Science Foundation of China, grant number U20A20388.