A Novel Nonlinear Method for Cardiovascular Data Synchronization

  • Padovano, Daniele
  • Martinez-Rodrigo, Arturo
  • Marwan, Norbert
  • Mula Muñoz, Santiago
  • Alcaraz, Raúl
  • Rieta, J J|||0000-0002-3364-6380
[EN] This study introduces and evaluates a novel nonlinear technique for synchronizing electrocardiogram (ECG) and photoplethysmogram (PPG) signals by embracing the intrinsic relationship between heart rate variability (HRV) and pulse rate variability (PRV). The proposed method utilizes normalized mutual information (NMI) derived from cross-distance matrices (CDM) of HRV and PRV, alongside the distance matrix of a reference HRV extract. We tested the methodology on two databases containing simultaneous ECG and PPG signals, including one publicly available on Physionet, and benchmarked it against various synchronization techniques, both linear (Pearson coefficient, dynamic time warping) and nonlinear (conventional mutual information, NMI with recurrence plots, cross-recurrence plot, and determinism). Results showed that the proposed method (NMI of CDM) outperformed all others, achieving synchronization rates near 50% within a 1.2-second lag threshold. This study also comprehensively examines how signal quality and recording methodology variations affect synchronization outcomes, confirming the importance of lag threshold adjustment for real accuracy assessment. However, some limitations must be kept in mind: the proposed approach is not suited for blood pressure estimation based on HRV-PRV differences, nonlinear methods generally require higher computational resources than linear ones, and further validation is needed with additional databases from real-world scenarios similar to those used in this study., This work was supported in part by MICIU/AEI/10.13039/501100011033, Fondo Europeo de Desarrollo Regional (FEDER) European Union (EU), and NextGenerationEU/Plan de Recuperacion, Transformacion y Resiliencia (PRTR) under Grant PID2021-128525OB-I00, Grant PID2021-123804OB-I00, and Grant TED2021-130935B-I00; in part by European Regional Development Fund (EU) from Junta de Comunidades de Castilla-La Mancha under Grant SBPLY/21/180501/000186 and Grant SBPLY/21/180225/000080; and in part by the Generalitat Valenciana under Grant AICO/2021/286. The work of Daniele Padovano was supported by the Predoctoral Scholarship, which is co-financed by the Operating Program of European Social Fund (ESF) (2014-2020) of Castilla-La Mancha under Grant 2022-PRED-20642.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Deep Learning and Recurrence Information Analysis for the Automatic Detection of Obstructive Sleep Apnea

  • Padovano, Daniele
  • Martinez-Rodrigo, Arturo
  • Pastor, José Manuel
  • Alcaraz, Raúl
  • Rieta, J J|||0000-0002-3364-6380
[EN] Obstructive sleep apnea (OSA) represents a significant health concern. While polysomnography (PSG) remains the gold standard, its resource-intensive nature has encouraged the exploration of further alternative approaches. Most of these were based on the heart rate variability (HRV) analysis, but only a few of them have presented a recurrence-based approach. The present paper addresses this gap by integrating convolutional neural networks (CNNs) with HRV recurrence analysis. Employing three different and publicly available databases from PhysioNet's official repository (Apnea-ECG, MIT-BIH, and UCD-DB), the presented method was able to expose concealed patterns within the distance matrix of HRV's phase space, which is discernible at an appropriate level of abstraction through CNNs. Under the challenging context of external validation (MIT-BIH and UCD for training, and Apnea-ECG for testing), the results obtained were comparable to those presented in the state of the art, achieving a peak accuracy of 75%, while maintaining balanced sensitivity and specificity at 74% and 75%, respectively. Moreover, these results obtained by the proposed CNN-based recurrence analysis of HRV also outperformed traditional time-frequency models, which have yielded values of accuracy lower than 65%. Hence, this paper highlights the importance of the proposed method in gaining new insights into OSA's HRV dynamics, offering a contribution that adds to the existing analytical approaches in the state of the art., This research has received financial support from public grants PID2021-128525OB-I00 and PID2021-123804OB-I00 of the Spanish Government 10.13039/501100011033 jointly with the European Regional Development Fund (EU), SBPLY/21/180501/000186 from Junta de Comunidades de Castilla-La Mancha, TED2021-130935B-I00, funded by the Spanish Government in conjunction with the European Regional Development Fund (EU), and AICO/2021/286 from Generalitat Valenciana. Moreover, Daniele Padovano holds a predoctoral scholarship 2022-PRED-20642, which is co-financed by the operating program of European Social Fund (ESF) 2014-2020 of Castilla-La Mancha.