Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Enhanced magnetic field concentration using windmill-like ferromagnets

  • Bort-Soldevila, Natanael|||0000-0001-9765-1843
  • Cunill-Subiranas, Jaume|||0000-0002-5612-2846
  • Barrera Català, Aleix|||0000-0002-7146-0026
  • Valle, Nuria del|||0000-0003-2608-5009
  • Silhanek, Alejandro|||0000-0001-9551-5717
  • Uhlíř, Vojtěch|||0000-0002-0512-6329
  • Bending, Simon|||0000-0002-4474-2554
  • Palau, Anna|||0000-0002-2217-164X
  • Navau, Carles|||0000-0003-4763-5305
Magnetic sensors are used in many technologies and industries, such as medicine, telecommunications, robotics, the Internet of Things, etc. The sensitivity of these magnetic sensors is a key aspect, as it determines their precision. In this article, we investigate how a thin windmill-like ferromagnetic system can hugely concentrate a magnetic field at its core. A magnetic sensor combined with such a device enhances its sensitivity by a large factor. We describe the different effects that provide this enhancement: the thickness of the device and its unique windmill-like geometry. An expression for the magnetic field in its core is introduced and verified using finite-element calculations. The results show that a high magnetic field concentration is achieved for a low thickness-diameter ratio of the device. Proof-of-concept experiments further demonstrate the significant concentration of the magnetic field when the thickness-diameter ratio is low, reaching levels up to 150 times stronger than the applied field.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Complete and robust magnetic field confinement by superconductors in fusion magnets

  • Bort-Soldevila, Natanael|||0000-0001-9765-1843
  • Cunill-Subiranas, Jaume|||0000-0002-5612-2846
  • Sánchez Moreno, Álvaro|||0000-0002-2988-0289
The fusion created by magnetically confined plasma is a promising clean and essentially unlimited future energy source. However, there are important problems hindering controlled fusion like the imperfect magnetic confinement and the associated plasma instabilities. We theoretically demonstrate how to create a fully confined magnetic field with the precise three-dimensional shape required by fusion theory, using a bulk superconducting toroid with a toroidal cavity. The vacuum field in the cavity consists of nested flux surfaces. The coils creating the field, embedded in the superconducting bulk, can be chosen with very simple shapes, in contrast with the cumbersome arrangements in current experiments, and can be spared from large magnetic forces between them. Because of the superconductor properties, the system will tend to maintain the optimum field distribution in response to instabilities in the plasma. We numerically demonstrate how a fully-confined magnetic field with the three-dimensional spatial distribution required in two of the most advanced stellarators, Large Helical Device and Wendelstein 7-X, can be exactly generated, using simple round coils as magnetic sources. Current high-temperature superconductors can be employed to construct the bulk superconducting toroid. This can lead to optimized robust magnetic confinement and largely simplified configurations in future fusion experiments.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Commensal and pathogenic bacteria of the respiratory tract of bats from Catalonia, North-Eastern Spain

  • Pasetto, Carlotta|||0009-0002-6625-0777
  • Lobato-Bailón, Lourdes|||0000-0003-2084-5513
  • Puig Ribas, Maria|||0000-0003-3242-0758
  • Aragón, Virginia|||0000-0002-3470-6015
  • Guixé, David
  • Caparroz Soto, Noel|||0009-0008-4050-0591
  • Camprodon, Jordi|||0000-0001-8457-9424
  • Martino, Laura|||0000-0002-0536-0115
  • Domingo, Mariano|||0000-0002-9623-4826
  • Obón, Elena|||0000-0003-4228-717X
  • Molina López, Rafael|||0000-0002-9043-2346
  • Fernández Aguilar, Xavier|||0000-0002-4939-6048
  • Cabezón Ponsoda, Óscar|||0000-0001-7543-8371
Bats host a diverse range of commensal and potentially pathogenic microorganisms, yet bacterial infections remain underrepresented in bat health research. This study investigated the diversity of bacteria of the respiratory tract in bats from Catalonia, North-Eastern Spain, including free-ranging individuals and those admitted to a wildlife rehabilitation centre. Oropharyngeal swabs were collected and processed for microbiological analysis from 182 apparently healthy bats belonging to 14 species, and from 28 bats admitted to the wildlife rehabilitation centre. Additionally, necropsy, microbiological and histopathological investigation were performed on 30 deceased individuals. A total of 394 bacterial isolates were recovered and identified by 16S rRNA gene sequencing, selected strains were further characterized by ERIC-PCR and phylogenetic analysis. The genus Vespertiliibacter, within the Pasteurellaceae family, was the most detected in apparently healthy bats and was significantly more prevalent in this group (59.3%) than in rehabilitated bats (35.7%, p = 0.024). By contrast, Pasteurella multocida subsp. septica was only identified in two cases of fatal pneumonia and sepsis in Pipistrellus kuhlii. Enterobacteriaceae were significantly more prevalent in rehabilitated bats (46.4%) than in free-ranging individuals (10.4%, p < 0.001). These findings expand current knowledge on the upper respiratory microbiota of bats, support the role of P. multocida as a primary pathogen in this group, and highlight the presence of bacterial species of potential clinical relevance for bat health.