Biomechanical loading as an alternative treatment for tremor: A review of two approaches

  • Rocon, Eduardo
  • Gallego, Juan Álvaro
  • Benito León, Julián
  • Pons, José Luis
  • Belda-Lois, Juan-Manuel|||0000-0002-7648-799X
[EN] Background: Tremor is the most common movement disorder and strongly increases in incidence and prevalence with aging. Although not life threatening, upper-limb tremors hamper the independence of 65% of people suffering from them affected persons, greatly impacting their quality of life. Current treatments include pharmacotherapy and surgery (thalamotomy and deep brain stimulation). However, these options are not sufficient for approximately 25% of patients. Therefore, further research and new therapeutic options are required to effectively manage pathological tremor. Methods: This paper presents findings of two research projects in which two different wearable robots for tremor management were developed based on force loading and validated. The first consisted of a robotic exoskeleton that applied forces to tremulous limbs and consistently attenuated mild and severe tremors. The second was a neuroprosthesis based on transcutaneous neurostimulation. A total of 22 patients suffering from parkinsonian or essential tremor (ET) of different severities were recruited for experimental validation, and both systems were evaluated using standard tasks employed for neurological examination. The inclusion criterion was a postural and/or kinetic pathological upper-limb tremor resistant to medication. Results: The results demonstrate that both approaches effectively suppressed tremor in most patients, although further research is required. The work presented here is based on clinical evidence from a small number of patients (n510 for robotic exoskeleton and n512 for the neuroprosthesis), but most had a positive response to the approaches. In summary, biomechanical loading is non-invasive and painless. It may be effective in patients who are insufficiently responsive (or have adverse reactions) to drugs or in whom surgery is contraindicated. Discussion: This paper identifies and evaluates biomechanical loading approaches to tremor management and discusses their potential, This research was supported by the projects DRIFTS(EU-QKL6-ICT-2002-00536), TREMOR (EU-ICT-2007-224051), NeuroTREMOR (EU-ICT-2011.5.1-287739), and the Spanish project REHABOT (DPI2008-06772-C03-01).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Metodología para la Creación de una Interfaz Cerebro-Computador Aplicada a la Identificación de la Intención de Movimiento, Methodology for building Brain-Computer Interfaces applied to identify voluntary movement intention

  • del Castillo, Mª D.
  • Serrano, J. I.
  • Ibáñez, J.
  • Barrios, L. J.
[EN] BCIs provide a channel for sending commands to the external environment by using electrophysiological measurements recording brain activity. The algorithm transforming the input signal into the output commands and the method used to extract the signal features for the algorithm are the key components for an optimum behaviour of the BCI. This paper presents a machine learning- based method to select these features and a classifier algorithm for building a predictive model from the EEg signal of patients with tremor. This model analyses and classifies the signal in a continous, asynchronous and adaptive way finding to identify the patient movement intention in order for a control system to cancel the tremor during the movement execution., [ES] Las Interfaces Cerebro-Computador proporcionan un canal para enviar órdenes al mundo exterior haciendo uso de medidas electrofisiológicas de la actividad cerebral. En este artículo se presenta la combinación de un método de selección de características y un algoritmo de clasificación probabilístico para construir el modelo predictivo de la intención anticipada de movimiento voluntario de pacientes con temblor a partir de un solo ensayo. Los resultados obtenidos muestran una potencial de discriminación del 70%, una tasa de error aceptable (6.6%) y una rápida respuesta (cada 250 ms), lo que indica que esta combinación es una buena base para la construcción de ICCs que no requieran entrenamiento del usuario de forma personalizada, asíncrona y adaptativa., Este trabajo ha sido realizado con la financiación de la Comisión de la Unión Europea dentro del 7 Programa Marco, para el proyecto con referencia ICT-2007-224051: “TREMOR: An ambulatory BCI-driven tremor suppression system based on functional electrical stimulation” y por el Ministerio de Ciencia e Innovación, con el proyecto IMAGENeuroMAPS (TEC2006-13966-C03-03) “Integración de resonancia magnética y electroencefalografía. Aplicación al fundamento y uso de ICCs por discapacitados”.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Analysis of kinematic data in pathological tremor with the Hilbert–Huang transform

  • Gallego, Juan Álvaro
  • Rocón, Eduardo
  • Koutsou, Aikaterini
  • Pons Rovira, José Luis
This paper presents analysis of kinematic data of tremor patients while performing different tasks with Ensemble Empirical Mode Decomposition (EEMD), a novel noise–assisted data analysis method. EEMD automatically separates raw kinematic data into three components: 1) noise from various sources, 2) tremulous movement, and 3) voluntary movement. Comparison of this technique with other decomposition meth- ods such as recursive forth and back filters or Empirical Mode Decomposition (EMD) shows a better performance; EEMD separation of tremor diminishes EMD error in a 45.2 % (mean error 0.041 ± 0.036 rad/s). Moreover, postprocessing of EEMD separated tremor allows the calculation of the Hilbert spectrum, a high resolution time–energy–frequency distribution that improves analysis of tremors, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

A neuroprosthesis for tremor management through the control of muscle co-contraction

  • Gallego, Juan Álvaro
  • Rocón, Eduardo
  • Belda-Lois, Juan Manuel
  • Pons Rovira, José Luis
[Background] Pathological tremor is the most prevalent movement disorder. Current treatments do not attain a significant tremor reduction in a large proportion of patients, which makes tremor a major cause of loss of quality of life. For instance, according to some estimates, 65% of those suffering from upper limb tremor report serious difficulties during daily living. Therefore, novel forms for tremor management are required. Since muscles intrinsically behave as a low pass filter, and tremor frequency is above that of volitional movements, the authors envisioned the exploitation of these properties as a means of developing a novel treatment alternative. This treatment would rely on muscle co-contraction for tremor management, similarly to the strategy employed by the intact central nervous system to stabilize a limb during certain tasks., [Methods] We implemented a neuroprosthesis that regulated the level of muscle co-contraction by injecting current at a pair of antagonists through transcutaneous neurostimulation. Co-contraction was adapted to the instantaneous parameters of tremor, which were estimated from the raw recordings of a pair of solid state gyroscopes with a purposely designed adaptive algorithm. For the experimental validation, we enrolled six patients suffering from parkinsonian or essential tremor of different severity, and evaluated the effect of the neuroprosthesis during standard tasks employed for neurological examination., [Results] The neuroprosthesis attained significant attenuation of tremor (p < 0.001), and reduced its amplitude up to a 52.33±25.48%. Furthermore, it alleviated both essential and parkinsonian tremor in spite of their different etiology and symptomatology. Tremor severity was not a limiting factor on the performance of the neuroprosthesis, although there was a subtle trend towards larger attenuation of more severe tremors. Tremor frequency was not altered during neurostimulation, as expected from the central origin of Parkinson’s disease and essential tremor. All patients showed a good tolerance to neurostimulation in terms of comfort and absence of pain, and some spontaneously reported that they felt that tremor was reduced when the neuroprosthesis was activated., [Conclusions] The results presented herein demonstrate that the neuroprosthesis provides systematic attenuation of the two major types of tremor, irrespectively from their severity. This study sets the basis for the validation of the neuroprosthesis as an alternative, non-invasive means for tremor management., This work has been supported by the Commission of the European Union through grants ICT2007-224051 (TREMOR) and ICT-2011-287739 (NeuroTREMOR), by the Spanish Ministry of Science and Innovation through grants DPI2008-06772-C03-01 (REHABOT) and CSD2009-00067 (HYPER), and by the IMPIVA through grant IMDEEA/2011/91 (SISTR2)., The authors also thank the Unit of Information Resources for Research (URICI-CSIC) for the co-financing of this publication in Open Access., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

A multimodal human–robot interface to drive a neuroprosthesis for tremor management

  • Gallego, Juan Álvaro
  • Ibáñez Pereda, Jaime
  • Dideriksen, Jakob L.
  • Serrano, José Ignacio
  • Castillo-Sobrino, M. Dolores del
  • Farina, Dario
  • Rocón, Eduardo
Tremor is the most prevalent movement disorder, and its incidence is increasing with aging. In spite of the numerous therapeutic solutions available, 65% of those suffering from upper limb tremor report serious difficulties during their daily living. This gives rise to research on different treatment alternatives, amongst which wearable robots that apply selective mechanical loads constitute an appealing approach. In this context, the current work presents a multimodal human-robot interface to drive a neuroprosthesis for tremor management. Our approach relies on the precise characterization of the tremor to modulate a functional electrical stimulation system that compensates for it. The neuroprosthesis is triggered by the detection of the intention to move derived from the analysis of electroencephalographic activity, which provides a natural interface with the user. When a prediction is delivered, surface electromyography serves to detect the actual onset of the tremor in the presence of volitional activity. This information in turn triggers the stimulation, which relies on tremor parameters-amplitude and frequency-derived from a pair of inertial sensors that record the kinematics of the affected joint. Surface electromyography also yields a first characterization of the tremor, together with precise information on the preferred stimulation site. Apart from allowing for an optimized performance of the system, our multimodal approach permits the implementation of redundant methods to both enhance the reliability of the system and adapt to the specific needs of different users. Results with a representative group of patients illustrate the performance of the interface presented here and demonstrate its feasibility., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Otros (Other)

Advances in the Assessment and Suppression of Pathological Tremor in the Framework of TREMOR Project

  • Gallego, Juan Álvaro
  • Rocón, Eduardo
  • Pons Rovira, José Luis
Pathological tremor is the most prevalent movement disorder, and is not effectively managed in a significant proportion of patients. In addition, the epidemiology and neurophysiology of tremors is yet not understood. This abstract summarizes our work on TREMOR project, which aimed at the development and validation of a wearable neuroprosthesis for tremor management. This neuroprosthesis comprised a multimodal interface to parameterize tremor during voluntary activities, and a functional electrical stimulation controller that attenuated tremor amplitude without affecting voluntary movement. Experimental results are reviewed, showing that both objectives were successfully reached., This work has been supported by the Commission of the European Union through grant ICT2007-224051 (TREMOR), and by the Spanish Ministry of Science and Innovation through grant DPI2008-06772-C03-01(REHABOT)., Peer Reviewed