Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 8
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Stability metrics for multi-source biomedical data based on simplicial projections from probability distribution distances

  • Sáez Silvestre, Carlos|||0000-0003-2678-8249
  • Garcia-Gomez, Juan M
  • Robles Viejo, Montserrat
[EN] Biomedical data may be composed of individuals generated from distinct, meaningful sources. Due to possible contextual biases in the processes that generate data, there may exist an undesirable and unexpected variability among the probability distribution functions (PDFs) of the source subsamples, which, when uncontrolled, may lead to inaccurate or unreproducible research results. Classical statistical methods may have difficulties to undercover such variabilities when dealing with multi-modal, multi-type, multi-variate data. This work proposes two metrics for the analysis of stability among multiple data sources, robust to the aforementioned conditions, and defined in the context of data quality assessment. Specifically, a global probabilistic deviation (GPD) and a source probabilistic outlyingness (SPO) metrics are proposed. The first provides a bounded degree of the global multi-source variability, designed as an estimator equivalent to the notion of normalized standard deviation of PDFs. The second provides a bounded degree of the dissimilarity of each source to a latent central distribution. The metrics are based on the projection of a simplex geometrical structure constructed from the Jensen-Shannon distances among the sources PDFs. The metrics have been evaluated and demonstrated their correct behaviour on a simulated benchmark and with real multi-source biomedical data using the UCI Heart Disease dataset. The biomedical data quality assessment based on the proposed stability metrics may improve the efficiency and effectiveness of biomedical data exploitation and research., The author(s) disclosed receipt of the following financial support for the research, authorship, and/or publication of this article: This work was supported by own IBIME funds under the UPV project Servicio de evaluacion y rating de la calidad de repositorios de datos biomedicos [UPV-2014-872] and the EU FP7 Project Help4Mood - A Computational Distributed System to Support the Treatment of Patients with Major Depression [ICT-248765].
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Mobile clinical decision support systems and applications: a literature and commercial review

  • Martínez Pérez, Borja
  • DE LA TORRE DIEZ, ISABEL
  • López Coronado, Miguel
  • Sainz de Abajo, Beatriz
  • Robles Viejo, Montserrat
  • Garcia-Gomez, Juan M
[EN] Background: The latest advances in eHealth and mHealth have propitiated the rapidly creation and expansion of mobile applications for health care. One of these types of applications are the clinical decision support systems, which nowadays are being implemented in mobile apps to facilitate the access to health care professionals in their daily clinical decisions. Objective: The aim of this paper is twofold. Firstly, to make a review of the current systems available in the literature and in commercial stores. Secondly, to analyze a sample of applications in order to obtain some conclusions and recommendations. Methods: Two reviews have been done: a literature review on Scopus, IEEE Xplore, Web of Knowledge and PubMed and a commercial review on Google play and the App Store. Five applications from each review have been selected to develop an in-depth analysis and to obtain more information about the mobile clinical decision support systems. Results: 92 relevant papers and 192 commercial apps were found. 44 papers were focused only on mobile clinical decision support systems. 171 apps were available on Google play and 21 on the App Store. The apps are designed for general medicine and 37 different specialties, with some features common in all of them despite of the different medical fields objective. Conclusions: The number of mobile clinical decision support applications and their inclusion in clinical practices has risen in the last years. However, developers must be careful with their interface or the easiness of use, which can impoverish the experience of the users., This research has been partially supported by Ministerio de Economía y Competitividad, Spain. This research has been partially supported by the ICT-248765 EU-FP7 Project. This research has been partially supported by the IPT-2011-1126-900000 project under the INNPACTO 2011 program, Ministerio de Ciencia e Innovación.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

A Novel Approach to Improve the Planning of Adaptive and Interactive Sessions for the treatment of Major Depression

  • Bresó Guardado, Adrián
  • Martínez Miranda, Juan Crisóforo
  • Fuster García, Elíes|||0000-0002-0716-8960
  • Garcia-Gomez, Juan M
[EN] Human Computer Interaction (HCI) is a research field which aims to improve the relationship between users and interactive computer systems. A main objective of this research area is to make the user experience more pleasant and efficient, minimizing the barrier between the users' cognition of what they want to accomplish and the computer's understanding of the user's tasks, by means of userfriendly, useful and usable designs. A bad HCI design is one of the main reasons behind user rejection of computer-based applications, which in turn produces loss of productivity and economy in industrial environments. In the eHealth domain, user rejection of computer-based systems is a major barrier to exploiting the maximum benefit from those applications developed to support the treatment of diseases, and in the worst cases a poor design in these systems may cause deterioration in the clinical condition of the patient. Thus, a high level of personalisation of the system according to users' needs is extremely important, making it easy to use and contributing to the system's efficacy, which in turn facilitates the empowerment of the target users. Ideally, the content offered through the interactive sessions in these applications should be continuously assessed and adapted to the changing condition of the patient. A good HCI design and development can improve the acceptance of these applications and contribute to promoting better adherence levels to the treatment, preventing the patient from further relapses. In this work, we present a mechanism to provide personalised and adaptive daily interactive sessions focused on the treatment of patients with Major Depression. These sessions are able to automatically adapt the content and length of the sessions to obtain personalised and varied sessions in order to encourage the continuous and long-term use of the system. The tailored adaptation of session content is supported by decision-making processes based on: (i) clinical requirements; (ii) the patient's historical data; and (iii) current responses from the patient. We have evaluated our system through two different methodologies: the first one performing a set of simulations producing different sessions from changing input conditions, in order to assess different levels of adaptability and variability of the session content offered by the system. The second evaluation process involved a set of patients who used the system for 14 to 28 days and answered a questionnaire to provide feedback about the perceived level of adaptability and variability produced by the system. The obtained results in both evaluations indicated good levels of adaptability and variability in the content of the sessions according to the input conditions., E. Fuster Garcia acknowledges the financial support from the "Torres Quevedo" program (Spanish Ministry of Economy and Competitiveness) co-funded by the European Social Fund (PTQ-12-05693), and the financial support from the Universitat Politecnica de Valencia under the Grant "Ayudas Para la Contratacion de Doctores para el Acceso al Sistema Espanol de Ciencia, Tecnologia e Innovacion" (PAID-10-14).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Fusing actigraphy signals for outpatient monitoring

  • Fuster García, Elíes|||0000-0002-0716-8960
  • Garcia-Gomez, Juan M
  • Bresó Guardado, Adrián
  • Martínez Miranda, Juan Crisóforo
  • Rosell-Ferrer, Javier
  • Matheson, Colin
[EN] Actigraphy devices have been successfully used as effective tools in the treatment of diseases such as sleep disorders or major depression. Although several efforts have been made in recent years to develop smaller and more portable devices, the features necessary for the continuous monitoring of outpatients require a less intrusive, obstructive and stigmatizing acquisition system. A useful strategy to overcome these limitations is based on adapting the monitoring system to the patient lifestyle and behavior by providing sets of different sensors that can be worn simultaneously or alternatively. This strategy offers to the patient the option of using one device or other according to his/her particular preferences. However this strategy requires a robust multi-sensor fusion methodology capable of taking maximum profit from all of the recorded information. With this aim, this study proposes two actigraphy fusion models including centralized and distributed architectures based on artificial neural networks. These novel fusion methods were tested both on synthetic datasets and real datasets, providing a parametric characterization of the models' behavior, and yielding results based on real case applications. The results obtained using both proposed fusion models exhibit good performance in terms of robustness to signal degradation, as well as a good behavior in terms of the dependence of signal quality on the number of signals fused. The distributed and centralized fusion methods reduce the mean averaged error of the original signals to 44% and 46% respectively when using simulated datasets. The proposed methods may therefore facilitate a less intrusive and more dependable way of acquiring valuable monitoring information from outpatients., This work was partially funded by the European Commission: Help4Mood (Contract No. FP7-ICT-2009-4: 248765). E. FusterGarcia acknowledges Programa Torres Quevedo from Ministerio de Educacion y Ciencia, co-founded by the European Social Fund (PTQ-12-05693).
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

A magnetic induction measurement system for adult vital sign monitoring: evaluation of capacitive and inductive effects

  • Mahdavi, Hadiseh
  • Rosell Ferrer, Francisco Javier|||0000-0002-9691-328X
Magnetic induction (MI) measurement technique could provide an unobtrusive contactless method for continuous monitoring of vital signs such as breathing and cardiac activity in bed. In this paper, we present a magnetic induction system to evaluate the feasibility of monitoring heart and lung activity and the preliminary measurement results. The excitation and detection coils are designed to be implemented in a single printed circuit board, allowing the use of the system in a bed with coils under the mattress. The electronic system is based on a 16 bit arbitrary waveform generator (PXI-5422, National instrument) operating at a sample rate of 200 MS/s for the excitation signal and the detected amplified signal is then, sampled at 100 MS/s by a 14 bit digitizer (PXI-5122, National Instruments). The preliminary results at 10 MHz show the ability of the system to detect solutions with different conductivities. However the capacitive effect is in the same order of magnitude as the inductive effect due to eddy currents. Safety of the system has been evaluated to be in accordance with the standards of human exposure to the magnetic fields.
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

The help4mood wearable sensor network for inconspicuous activity measurement

  • Pérez Díaz de Cerio, David|||0000-0003-0735-6811
  • Ruiz Boqué, Sílvia|||0000-0002-4672-2493
  • Rosell Ferrer, Francisco Javier|||0000-0002-9691-328X
  • Ramos Castro, Juan José|||0000-0001-9413-2001
  • Valenzuela González, José Luis|||0000-0002-7238-2621
  • Colomé Castellví, Josep Maria
The Help4Mood EU FP7 project (H4M) [1] proposes to significantly advance the state-ofthe-art in computerized support for people with Major Depression by monitoring mood, physical activity and voice characteristics while promoting activities in reaction to examined inputs. Employing actigraphy can provide supplementary data about patients with depression. Nonetheless, its use is not standardized and there is a lack of public analyses about treated patients with depression using this technique, which is the objective of the project. The purpose of the Personal Monitoring System (PMS) used in H4M is to compile objective data about the changes and trends of activity patterns during long periods of time. This would comprise daily activity, rest time and, if possible, sleep quality. The PMS uses inconspicuous methods but keeping the cost associated with sensor installation at the patient¿s home to a minimum. This work focuses on the Wireless Sensor Network (WSN) enhancements introduced after real testbeds and considering User Quality of Experience (QoE), mainly oriented to reduce energy consumption and required data transmission and consequently improving the autonomy and range of the sensors., Peer Reviewed
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

A magnetic induction measurement system for adult vital sign monitoring: evaluation of capacitive and inductive effects

  • Mahdavi, Hadiseh
  • Rosell Ferrer, Francisco Javier
Magnetic induction (MI) measurement technique could provide an unobtrusive contactless method for continuous monitoring of vital signs such as breathing and cardiac activity in bed. In this paper, we present a magnetic induction system to evaluate the feasibility of monitoring heart and lung activity and the preliminary measurement results. The excitation and detection coils are designed to be implemented in a single printed circuit board, allowing the use of the system in a bed with coils under the mattress. The electronic system is based on a 16 bit arbitrary waveform generator (PXI-5422, National instrument) operating at a sample rate of 200 MS/s for the excitation signal and the detected amplified signal is then, sampled at 100 MS/s by a 14 bit digitizer (PXI-5122, National Instruments). The preliminary results at 10 MHz show the ability of the system to detect solutions with different conductivities. However the capacitive effect is in the same order of magnitude as the inductive effect due to eddy currents. Safety of the system has been evaluated to be in accordance with the standards of human exposure to the magnetic fields., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

The help4mood wearable sensor network for inconspicuous activity measurement

  • Pérez Díaz de Cerio, David
  • Ruiz Boqué, Sílvia
  • Rosell Ferrer, Francisco Javier
  • Ramos Castro, Juan José
  • Valenzuela González, José Luis
  • Colomé Castellví, Josep Maria
The Help4Mood EU FP7 project (H4M) [1] proposes to significantly advance the state-ofthe-art in computerized support for people with Major Depression by monitoring mood, physical activity and voice characteristics while promoting activities in reaction to examined inputs. Employing actigraphy can provide supplementary data about patients with depression. Nonetheless, its use is not standardized and there is a lack of public analyses about treated patients with depression using this technique, which is the objective of the project. The purpose of the Personal Monitoring System (PMS) used in H4M is to compile objective data about the changes and trends of activity patterns during long periods of time. This would comprise daily activity, rest time and, if possible, sleep quality. The PMS uses inconspicuous methods but keeping the cost associated with sensor installation at the patient¿s home to a minimum. This work focuses on the Wireless Sensor Network (WSN) enhancements introduced after real testbeds and considering User Quality of Experience (QoE), mainly oriented to reduce energy consumption and required data transmission and consequently improving the autonomy and range of the sensors., Peer Reviewed, Postprint (published version)