Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Exploring Ventilation Efficiency in Poultry Buildings: The Validation of Computational Fluid Dynamics (CFD) in a Cross-Mechanically Ventilated Broiler Farm

  • Bustamante García, E.|||0000-0002-9062-3062
  • García Diego, Fernando Juan|||0000-0002-7062-245X
  • Calvet, S.|||0000-0001-6639-9892
  • Beltrán Medina, Pedro
  • Hospitaler Pérez, Antonio|||0000-0001-7108-3104
  • Estellés, Fernando
  • Torres Salvador, Antonio Germán
[EN] Broiler production in modern poultry farms commonly uses mechanical ventilation systems. This mechanical ventilation requires an amount of electric energy and a high level of investment in technology. Nevertheless, broiler production is affected by periodic problems of mortality because of thermal stress, thus being crucial to explore the ventilation efficiency. In this article, we analyze a cross-mechanical ventilation system focusing on air velocity distribution. In this way, two methodologies were used to explore indoor environment in livestock buildings: Computational Fluid Dynamics (CFD) simulations and direct measurements for verification and validation (V&V) of CFD. In this study, a validation model using a Generalized Linear Model (GLM) was conducted to compare these methodologies. The results showed that both methodologies were similar in results: the average of air velocities values were 0.60 ± 0.56 m s−1 for CFD and 0.64 ± 0.54 m s−1 for direct measurements. In conclusion, the air velocity was not affected by the methodology (CFD or direct measurements), and the CFD simulations were therefore validated to analyze indoor environment of poultry farms and its operations. A better knowledge of the indoor environment may contribute to reduce the demand of electric energy, increasing benefits and improving the thermal comfort of broilers, This work was funded by the project GV04B-511 (Generalitat Valenciana, Spain) and by the Vicerrectorado of Investigacion of the Universitat Politecnica de Valencia (Programa de Apoyo a la Investigacion y Desarrollo Multidisciplinar Project PAID register 2614).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Strategies to control odours in livestock facilities: a critical review

  • Úbeda Sánchez, Yolanda
  • Nicolas, J.
  • López Jiménez, Petra Amparo|||0000-0002-7043-3683
  • Calvet, S.|||0000-0001-6639-9892
[EN] Los olores generados en instalaciones ganaderas constituyen uno de los temas más relevantes de calidad del aire de la ganadería intensiva de producción . La reducción de los episodios molestos relacionados con la exposición de olores por tanto, es esencial para una ganadería sostenible producción . En este estudio, se revisa críticamente el estado - del- arte en las técnicas de reducción de olores en alojamientos para el ganado . Los avances científicos en la última década se revisan y necesidades de investigación también se identifican . La naturaleza compleja de la ganadería y los olores es una parte crítica . Aqui, las estrategias de control de olores más relevantes se analizan en términos de los conocimientos actuales y las necesidades futuras . Las estrategias que se consideran son : estrategias nutricionales , aditivos para estiércol, construcción diseño, filtración de aire , tapas de estiércol, los sistemas de tratamiento del estiércol y cortavientos . Por último , la investigación futura necesita y se identifican las prioridades al establecer técnicas de mitigación . A pesar de los importantes avances recientes, todavía hay algunos desafíos para los científicos, los productores y los reguladores , en particular relacionados con la evaluación de campo de los olores . Por lo tanto , para controlar los olores del ganado de manera efectiva , el uso de técnicas de evaluación de campo estandarizados serán requeridos . además, que investigan los errores de medición y de modelo pueden ser útiles para comprender mejor las limitaciones de los métodos actuales , así como para identificar las prioridades de investigación ., This work has been possible within the framework of the research project “Línea multidisciplinar para aplicación de las técnicas de la mecánica de fluidos computacional a modelación de movimiento de flujos ambientales (2614)” from Vicerrectorado de Investigación, Universidad Politécnica de Valencia, Spain.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Measurement and Numerical Simulation of Air Velocity in a Tunnel-Ventilated Broiler House

  • Bustamante García, E.|||0000-0002-9062-3062
  • García Diego, Fernando Juan|||0000-0002-7062-245X
  • Calvet, S.|||0000-0001-6639-9892
  • Hospitaler Pérez, Antonio|||0000-0001-7108-3104
  • Torres Salvador, Antonio Germán
A building needs to be designed for the whole period of its useful life according to its requirements. However, future climate predictions involve some uncertainty. Thus, several sustainable strategies of adaptation need to be incorporated after the initial design. In this sense, tunnel ventilation in broiler houses provides high air velocity values (2-3 m center dot s(-1)) at animal level to diminish their thermal stress and associated mortality. This ventilation system was experimentally incorporated into a Mediterranean climate. The aim was to resolve these thermal problems in hot seasons, as (traditional) cross-mechanical ventilation does not provide enough air velocity values. Surprisingly, very little information on tunnel ventilation systems is available, especially in terms of air velocity. Using Computational Fluid Dynamics (CFD) and a multi-sensor system, the average results are similar (at animal level: 1.59 +/- 0.68 m center dot s(-1) for CFD and 1.55 +/- 0.66 m center dot s(-1) for measurements). The ANOVA for validation concluded that the use of CFD or measurements is not significant (p-value = 0.1155). Nevertheless, some problems with air velocity distribution were found and need to be solved. To this end, CFD techniques can help by means of virtual designs and scenarios providing information for the whole indoor space., This work was funded by the project GV04B-511 (Generalitat Valenciana, Spain) and by the Vicerrectorado of Investigacion of the Universitat Politecnica de Valencia (Programa de Apoyo a la Investigacion y Desarrollo Multidisciplinar Project PAID register 2614).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Measurement and numerical simulation of single-sided mechanical ventilation in broiler houses

  • Bustamante García, E.|||0000-0002-9062-3062
  • Calvet, S.|||0000-0001-6639-9892
  • Estellés, F.|||0000-0001-6774-6075
  • Hospitaler Pérez, Antonio|||0000-0001-7108-3104
  • Torres, A.G.
[EN] In recent years, some broiler production farms especially in Mediterranean areas, have incorporated single-sided mechanical ventilation (i.e. air inlets and fans are located in the same lateral wall). However, little scientific information on the performance of mechanical single-sided ventilation systems is available to date. This ventilation method is fitted to broiler houses because this ventilation system appears appropriate to diminish the stress and mortality of broilers during hot seasons in this climate. To analyse the single-sided ventilation method scientifically, the indoor environments of broiler houses were examined by numerical simulation using computational fluid dynamics (CFD) with validation using a range of different buildings with direct measurements using a multi-sensor system. An analysis of variation of the results of the validation tests produced to a p-value of 0.3908. Thus, the methodology employed (i.e. CFD or sensors) was not significant. The CFD simulations showed a wide range of values for air velocity: the minimum value of air velocity at broiler level was 0.52 +/- 0.40 m s(-1) and the maximum was 1.29 +/- 0.41 m s(-1). Two major conclusions were drawn in terms indoor air velocity: (i) excessive heterogeneity in the plane where the animals were located; and (ii) insufficient air movement to contribute to the thermoregulation of the birds and lower their internal heat and associated thermal stress in occasional periods of hot weather., This work was funded by the project GV04B-511 (Generalitat Valenciana, Spain) and by the Vicerrectorado of Investigacion of the Universitat Politecnica de Valencia (Programa de Apoyo a la Investigacion y Desarrollo Multidisciplinar Project PAID register 2614).