Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 8
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Forward tracking at the next e+e- collider part II: experimental challenges and detector design

  • Aplin, S.
  • Boronat Arévalo, Marçà
  • Dannheim, D.
  • Duarte Campderros, J.
  • Gaede, F.
  • Ruiz Jimeno, Alberto
  • Sailer, André
  • Valentan, M.
  • Vila, Iván
  • Vos, Marcel
Published under the terms of the Creative Commons Attribution 3.0 License., We present the second in a series of studies into the forward tracking system for a future linear e+e- collider with a center-of-mass energy in the range from 250 GeV to 3 TeV. In this note a number of specific challenges are investigated, which have caused a degradation of the tracking and vertexing performance in the forward region in previous experiments. We perform a quantitative analysis of the dependence of the tracking performance on detector design parameters and identify several ways to mitigate the performance loss for charged particles emitted at shallow angle.© CERN 2013., This work has been partly supported by Grants FPA2010-22163-C02-01 and FPA2010-21549-C04-4 of the Spanish Ministry of Economy and Competitiveness; and by the European Commission within Framework Programme 7 Capacities, Grant Agreement 262025 (AIDA)., Peer reviewed, Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

2D position sensitive microstrip sensors with charge division along the strip: Studies on the position measurement error

  • Bassignana, D.
  • Currás, Esteban
  • Fernández-García, Marcos
  • Jaramillo, R.
  • Lozano Fantoba, Manuel
  • Muñoz Sánchez, F. J.
  • Pellegrini, Giulio
  • Quirion, David
  • Vila, Iván
  • Vitorero, F.
Position sensitivity in semiconductor detectors of ionizing radiation is usually achieved by the segmentation of the sensing diode junction in many small sensing elements read out separately as in the case of conventional microstrips and pixel detectors. Alternatively, position sensitivity can be obtained by splitting the ionization signal collected by one single electrode amongst more than one readout channel with the ratio of the collected charges depending on the position where the signal was primary generated. Following this later approach, we implemented the charge division method in a conventional microstrip detector to obtain position sensitivity along the strip. We manufactured a proof-of-concept demonstrator where the conventional aluminum electrodes were replaced by slightly resistive electrodes made of strongly doped poly-crystalline silicon and being readout at both strip ends. Here, we partially summarize the laser characterization of this first proof-of-concept demonstrator with special emphasis on the study on how the different noise sources are affecting the device position error along the strip. © 2013 Elsevier B.V. © 2013 Elsevier Ltd. All rights reserved., The research underlying this work has been partly supported by the Spanish Ministry of Economy and Competitiveness, grants FPA2010-22163-C02-01(-02); the European Commission under the FP7 Research Infrastructures project AIDA, grant agreement No. 262025; and by the GICSERV program “Access to ICTS integrated nano and micro electronics cleanroom” of the Spanish Ministry of Science of Innovation., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Radiation resistance of double-type double-sided 3D pixel sensors

  • Fernández-García, Marcos
  • Jaramillo, R.
  • Lozano Fantoba, Manuel
  • Muñoz Sánchez, F. J.
  • Pellegrini, Giulio
  • Quirion, David
  • Rohe, T.
  • Vila, Iván
The proposed high-luminosity upgrade of the Large Hadron Collider is expected to increase the instantaneous luminosity at the experiments' interaction points by a factor of ten. The vertex detector will be the subsystem most affected by the luminosity increase, raising substantially their occupancy and radiation-induced damage. To preserve the vertex physics performance under these new conditions, current pixel technologies have to be improved. Hybrid pixel sensors with double-sided double-type vertical electrodes (3D sensors) are becoming a mature technology for the detector layers closest to the interaction point due to their intrinsic radiation hardness. In addition, the double-sided implementation of the 3D pixel technology provides some additional technical advantages with respect to the single-sided implementation. For this study, 3D pixel sensors manufactured at the Centro Nacional de Microelectrónica of Barcelona (IMB-CNM) have been bonded to the PSI46 readout chip currently used by the Compact Muon Solenoid vertex detector. Detector performance before and after irradiation up to fluences of 5×1015neq/ cm2 is presented. © 2013 Elsevier Ltd. All rights reserved., The research underlying this work has been partly supported by the Spanish Ministry of Economy and Competitiveness, Grants FPA2010-22163-C02-01(-02) and FPA2010-22060-C02-01(-02); the European Commission under the FP7 Research Infrastructures project AIDA, Grant agreement no. 262025; and by the GICSERV program “Access to ICTS integrated nano and micro electronics cleanroom” of the Spanish Ministry of Science of Innovation., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Impact of low-dose electron irradiation on n+p silicon strip sensors

  • Klanner, R.
  • Jaramillo, R.
  • Fernández-García, Marcos
  • Gómez, Gervasio
  • Moya, David
  • González Sánchez, J.
  • Vila, Iván
  • López Virto, A.
  • CMS Collaboration
Under a Creative Commons license., The Tracker Group of the CMS Collaboration.-- et al., The response of n+p silicon strip sensors to electrons from a 90Sr source was measured using a multi-channel read-out system with 25 ns sampling time. The measurements were performed over a period of several weeks, during which the operating conditions were varied. The sensors were fabricated by Hamamatsu Photonics on 200 μm thick float-zone and magnetic-Czochralski silicon. Their pitch was 80 μm, and both p-stop and p-spray isolation of the n+ strips were studied. The electrons from the 90Sr source were collimated to a spot with a full-width-at-half-maximum of 2 mm at the sensor surface, and the dose rate in the SiO2 at the maximum was about 50 Gy(SiO2)/d. After only a few hours of making measurements, significant changes in charge collection and charge sharing were observed. Annealing studies, with temperatures up to 80 °C and annealing times of 18 h showed that the changes can only be partially annealed. The observations can be qualitatively explained by the increase of the positive oxide-charge density due to the ionization of the SiO2 by the radiation from the β source. TCAD simulations of the electric field in the sensor for different oxide-charge densities and different boundary conditions at the sensor surface support this explanation. The relevance of the measurements for the design of n+p strip sensors is discussed., The research leading to these results has received funding from the European Commission under the FP7 Research Infrastructures project AIDA, grant agreement no. 262025. We are also grateful to the HGF Alliance Physics at the Terascale, which has partially funded the setup used for the measurements, and to the BMBF, the Ministry of Research and Education of the German Federal Republic, for funding the Ph.D. position of J. Erfle within the Forschungsschwerpunkt FSP-102, Elementarteilchenphysik mit dem CMS-Experiment., Open Access funded by CERN., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Radiation hardness studies of neutron irradiated CMOS sensors fabricated in the ams H18 high voltage process

  • Fernández-García, Marcos
  • Gallrapp, Christian
  • Moll, Michael
  • Muenstermann, D.
High voltage CMOS detectors (HVCMOSv3), fabricated in the ams H18 high voltage process, with a substrate resistivity of 10 Ωcenterdotcm were irradiated with neutrons up to a fluence of 2 × 1016 neq/cm2 and characterized using edge-TCT. It was found that, within the measured fluence range, the active region and the collected charge reach a maximum at about 7 × 1015 neq/cm2 to decrease to the level of the unirradiated detector after 2 × 1016 neq/cm2., The research leading to these results has received funding from the European Commission under the FP7 Research Infrastructures project AIDA, grant agreement no. 262025. This work has been partially supported by the Spanish Ministry Economy and Competitiveness (MINECO) under grant number FPA2013-48387-C6-1-P., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

High-resolution three-dimensional imaging of a depleted CMOS sensor using an edge Transient Current Technique based on the Two Photon Absorption process (TPA-eTCT)

  • Fernández-García, Marcos
  • González Sánchez, J.
  • Jaramillo, R.
  • Moll, Michael
  • Montero Santos, Raúl
  • Moya, David
  • Palomo, Francisco Rogelio
  • Vila, Iván
For the first time, the deep n-well (DNW) depletion space of a High Voltage CMOS sensor has been characterized using a Transient Current Technique based on the simultaneous absorption of two photons. This novel approach has allowed to resolve the DNW implant boundaries and therefore to accurately determine the real depleted volume and the effective doping concentration of the substrate. The unprecedented spatial resolution of this new method comes from the fact that measurable free carrier generation in two photon mode only occurs in a micrometric scale voxel around the focus of the beam. Real three-dimensional spatial resolution is achieved by scanning the beam focus within the sample., This work was performed in the framework of the CERN-RD50 collaboration under the project RD50-2015-03. The project has received funding from the European Commission under the FP7 Research Infrastructures project AIDA, grant agreement no. 262025. This project has been partially supported by the Spanish Ministry of Economy and Competitiveness (MINECO) under grant number FPA2013-48387-C6-1-P., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Experimental study of different silicon sensor options for the upgrade of the CMS Outer Tracker

  • Currás, Esteban
  • Duarte Campderros, J.
  • Fernández-García, Marcos
  • Gómez, Gervasio
  • González Sánchez, J.
  • Jaramillo, R.
  • Moya, David
  • Silva Jimenez, E.
  • Vila, Iván
  • López Virto, A.
  • CMS Collaboration
CMS Collaboration: et al., During the high-luminosity phase of the LHC (HL-LHC), planned to start in 2027, the accelerator is expected to deliver an instantaneous peak luminosity of up to 7.5×1034 cm−2 s−1. A total integrated luminosity of 0300 or even 0400 fb−1 is foreseen to be delivered to the general purpose detectors ATLAS and CMS over a decade, thereby increasing the discovery potential of the LHC experiments significantly. The CMS detector will undergo a major upgrade for the HL-LHC, with entirely new tracking detectors consisting of an Outer Tracker and Inner Tracker. However, the new tracking system will be exposed to a significantly higher radiation than the current tracker, requiring new radiation-hard sensors. CMS initiated an extensive irradiation and measurement campaign starting in 2009 to systematically compare the properties of different silicon materials and design choices for the Outer Tracker sensors. Several test structures and sensors were designed and implemented on 18 different combinations of wafer materials, thicknesses, and production technologies. The devices were electrically characterized before and after irradiation with neutrons, and with protons of different energies, with fluences corresponding to those expected at different radii of the CMS Outer Tracker after 0300 fb−1. The tests performed include studies with β sources, lasers, and beam scans. This paper compares the performance of different options for the HL-LHC silicon sensors with a focus on silicon bulk material and thickness., The research leading to these results has received funding from the European Commission under the FP7 Research Infrastructures project AIDA, grant agreement no. 262025., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Characterisation of irradiated thin silicon sensors for the CMS phase II pixel upgrade

  • CMS Collaboration
  • Fernández-García, Marcos
  • Gómez, Gervasio
  • Jaramillo, R.
  • Moya, David
  • Gonzalez Sanchez, J.
  • Vila, Iván
  • López Virto, A.
The Tracker Group of the CMS Collaboration: et al., The high luminosity upgrade of the Large Hadron Collider, foreseen for 2026, necessitates the replacement of the CMS experiment’s silicon tracker. The innermost layer of the new pixel detector will be exposed to severe radiation, correspondingtoa1MeVneutronequivalentfluenceofupto eq = 2×1016cm−2, and an ionising dose of≈5M Gyafter an integrated luminosity of 3000 fb−1. Thin, planar silicon sensors are good candidates for this application, since the degradation of the signal produced by traversing particles is less severe than for thicker devices. In this paper, the results obtained from the characterisation of 100 and 200 µm thick p-bulk pad diodes and strip sensors irradiated up to fluences of eq =1.3×1016 cm−2 are shown., The research leading to these results has received funding from the European Commission under the FP7 Research Infrastructures project AIDA, Grant agreement no. 262025 and the PIER Ideenfonds PIF-2013-23., Peer reviewed