Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Non-equilibrium coupling of a quartz resonator to ions for Penning-trap fast resonant detection

  • Berrocal, Joaquín
  • Lohse, Steffen
  • Domínguez, Francisco
  • Gutiérrez, Manuel J.
  • Fernández, Francisco J.
  • Block, Michael
  • García-Ripoll, Juan José
  • Rodríguez, Daniel
11 pags., 10 figs., 2 tabs., The coherent coupling between a quartz electro-mechanical resonator at room temperature and trapped ions in a 7 T Penning trap has been demonstrated for the first time. The signals arising from the coupling remain for integration times in the orders of seconds. From the measurements carried out, we demonstrate that the coupling allows detecting the reduced-cyclotron frequency (ν +) within times in the order of the decay-time constant of the energized resonator (below 10 ms), regardless of the data-acquisition time-window in use, and providing an improved resolution compared to conventional electronic detection schemes. A resolving power ν +/Δν + = 2.4 107 has been reached in single measurements. In this publication we present the first results, emphasizing the novel features of the quartz resonator as fast non-destructive ion-trap detector together with different ways to analyze the data and considering aspects like precision, resolution and sensitivity., We acknowledge support from the Spanish MCINN through the projects FPA2015-67694-P, and PID2019-104093GB-I00/AEI/10.01339/501100011033, and contract number PTA2018-016573-I, from the Spanish Ministry of Education through PhD fellowship FPU17/02596, and from the University of Granada ‘Plan propio-Programa de Intensificacion de la Investigacion’, project PP2017-PRI.I-04 and ‘Laboratorios ´ Singulares 2020’. The construction of the facility was supported by the European Research Council (contract No. 278648-TRAPSENSOR), the above-mentioned project FPA2015-67694-P, project FPA2012-32076, and the infrastructure projects UNGR10-1E-501, UNGR13-1E-1830 and EQC2018- 005130-P (MICINN/FEDER/Universidad de Granada), and the infrastructure projects IE-5713 and IE2017-5513 (Junta de Andalucía-FEDER). MB and SL acknowledge financial support by the German BMBF in the project 05P18UMFN1. JJGR acknowledges support from CSIC Technology Platform PTI-001 and CAM PRICYT project QUITEMAD+CM S2013-ICE2801.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

A Coupled-Oscillators Model to Analyze the Interaction between a Quartz Resonator and Trapped Ions

  • Altozano, Emilio
  • Berrocal, Joaquín
  • Lohse, Steffen
  • Domínguez, Francisco
  • Block, Michael
  • García-Ripoll, Juan José
  • Rodríguez, Daniel
13 pages, 9 figures, The novel application of a piezoelectric quartz resonator for the detection of trapped ions has developed in the observation of the quartz-ions interaction under non-equilibrium conditions, opening new perspectives for high-sensitive motional frequency measurements of radioactive particles. Energized quartz crystals have (long) constant-decay times in the order of milliseconds, permitting the coherent detection of charged particles within short times. In this publication we develop in detail a model governing the interaction between trapped $^{40}$Ca$^+$ ions and a quartz resonator connected to a low-noise amplifier. We apply this model to experimental data and extract relevant information like the coupling constant $g=2\pi \times 1.449(2)$~Hz and the ions' modified-cyclotron frequency in our 7-tesla Penning trap. The study on the latter is specially important for the use of this resonator in precision Penning-trap mass spectrometry. The improvement in sensitivity can be accomplished by increasing the coupling constant through the quality factor of the resonator. This can develop in the use of the hybrid quartz-ion system for other applications., We acknowledge support from the Spanish MCINN through Project No. PID2019-104093GBI00/AEI/10.13039/501100011033 and Contract No.PTA2018-016573-I, and from the Andalusian Government through Project No. P18-FR-3432 and Fondo Operativo FEDER Grant No. A-FQM-425-UGR18, from the Spanish Ministry of Education through Ph.D. fellowship Grant No. FPU17/02596, and from the University of Granada “Plan propio—Programa de Intensificación de la Investigación,” Project No. PP2017-PRI.I-04 and “Laboratorios Singulares 2020.” J.J.G.-R. acknowledges support from the CAM/FEDER Project No. S2018/TCS-4342 (QUITEMADCM), CSIC Interdisciplinary Thematic Platform (PTI+) on Quantum Technologies (PTI-QTEP+). The construction of the facility was supported by the European Research Council (Contract No. 278648-TRAPSENSOR), Projects No. FPA2015-67694-P and No. FPA2012-32076; infrastructure Projects No. UNGR10-1E-501, No. UNGR13-1E-1830, and No. EQC2018-005130-P (MICINN/FEDER/UGR), and Grants No. IE-5713 and No. IE2017-5513 (Junta de Andalucía-FEDER)., Peer reviewed