Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 9
Encontrada(s) 1 página(s)

e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publicación Artículo científico (JournalArticle)

A Customized Light Sheet Microscope to Measure Spatio-Temporal Protein Dynamics in Small Model Organisms

  • Ripoll Lorenzo, Jorge
  • Rieckher, Matthias
  • Kyparissidis-Kokkinidis, Ilias
  • Zacharopoulos, Athanasios
  • Kourmoulakis, Georgios
  • Zacharakis, Giannis
  • Tavernarakis, Nektarios
We describe a customizable and cost-effective light sheet microscopy (LSM) platform for rapid three-dimensional imaging of protein dynamics in small model organisms. The system is designed for high acquisition speeds and enables extended time-lapse in vivo experiments when using fluorescently labeled specimens. We demonstrate the capability of the setup to monitor gene expression and protein localization during ageing and upon starvation stress in longitudinal studies in individual or small groups of adult Caenorhabditis elegans nematodes. The system is equipped to readily perform fluorescence recovery after photobleaching (FRAP), which allows monitoring protein recovery and distribution under low photobleaching conditions. Our imaging platform is designed to easily switch between light sheet microscopy and optical projection tomography (OPT) modalities. The setup permits monitoring of spatio-temporal expression and localization of ageing biomarkers of subcellular size and can be conveniently adapted to image a wide range of small model organisms and tissue samples., MR, GZ and AZ acknowledge funding from the Projects “Skin-DOCTor” Grant No. 1778 and “Neureka!” Grant No. LSF7-341 implemented under the "ARISTEIA" and "Supporting Postdoctoral Researchers" Actions respectively, of the "OPERATIONAL PROGRAMME EDUCATION AND LIFELONG LEARNING", (http://www.espa.gr/en/pages/staticOPEducationandLifelongLearning.aspx), which is co-funded by the European Social Fund and National Resources and from the EU Marie Curie Initial Training Network “OILTEBIA”, Grant No. PITNGA-2012-317526 (http://ec.europa.eu/research/mariecurieactions/, http://gdo.uc3m.es/oiltebia/index. php?option = com_content&view = frontpage). JR acknowledges support from EC FP7 CIG grant HIGHTHROUGHPUT TOMO PICIG12-GA-2012-333632, (http://cordis.europa.eu/projects/333632), and Spanish MINECO grant MESO-IMAGING FIS2013-41802-R, (https://sede.micinn.gob.es/). The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publicación Tesis doctoral (DoctoralThesis)

Terahertz time-domain spectroscopy to characterize graphene nanostructures for new optoelectronic applications

  • Dadrasnia, Ehsan
Terahertz electromagnetic waves from 0.1 to 30 THz, bounded between the infrared and microwave regions of the spectrum, has been intensively attracted to explore scientific and engineering phenomena for the materials. The graphene, a single layer of carbon atoms in a hexagonal lattice with zero energy band gap, and the carbon nanotube, sheet of graphene rolled into a cylinder, have been widely recognized as the perfect options for next generation ultrafast high performance optoelectronic applications to operate at the sub-THz and THz frequencies. Measuring the electrical conductivity and carriers' responses of such very thin conductance materials in devices could be rather difficult because of the contact issue. The terahertz time-domain spectroscopy (THz-TDS) is a noncontact tool to measure the optical and electrical parameters of the nanometrics semiconductors/semimetals. This work analysis the THz-TDS signals from the references and samples measurement. It studies the THz frequency-dependent of the electrical and optical properties of the nanostructure graphene-like materials from the transmission and reflection of a home-made THz-TDS, mainly in the frequency range of 0.1-2 THz. The DC conductivity could not be directly determined, as the available THz power decreases sharply and falls below the noise level at lower frequencies. The electrical and optical frequency-dependent parameters are rather noisy due to thickness of thin films compared to the thick substrates and also the limited sensitivity of the THz-TDS set-up over 1.5 THz. In this thesis results obtained, for the first time, on the characterization and spectroscopic analysis of the graphene-like samples deposited on the top of the quartz substrate, not only at the THz frequencies but also in the zero-frequency, so-achieved DC level, and far-infrared regime are presented. The conductivity values of such fragile materials are extracted from noncontact measurements at THz frequencies using elaborated conductivity Drude and non-Drude models which nicely fit the experimental data, giving information on the physics of electrical conductivity in these materials. The carrier’s transport, scattering and density near the Dirac point of graphene and carbon nanostructure are extracted by combining the measures THZ with the Drude models/non-Drude conductivity. This procedure is validated by the good agreement between the extracted DC conductivity from the THz measurements and the micrometer classical four-point probe in-line contact ones. The extrapolated characteristic length from THz measurement enables us to predict the cut-off frequency of such materials before applying to the optoelectronic devices. This thesis presents a commercially relevant application of noncontact THz-TDS techniques and analysis for the electrical characterization of nanoscale semiconductors and polymers with high mobility in the new generation of optoelectronic devices., Las ondas electromagnéticas en la región de terahercios de 0.1 a 30 THz, cuyo espectro está contenido entre las regiones del infrarrojo y las microondas, han sido intensamente utilizadas en la investigación científica e ingeniería de materiales. El grafeno, una única capa de átomos de carbono constituída por una red hexagonal con banda prohibida de energía cero y lo nanotubo de carbono como una lámina de grafeno enrollado formando un cilindro, han sido ampliamente reconocidos como la opción perfecta para la siguiente generación de aplicaciones optoelectrónicas ultrarrápidas y de alto rendimiento para operar en la región de terahercios. Medir la conductividad eléctrica y la respuesta de las portadoras de materiales tan delgados en dispositivos de medida es difícil debido a los problemas que supone el conectarlos físicamente. La espectroscopia de terahercios en el dominio del tiempo (THz-TDS) es una herramienta que no requiere contacto físico para medir parámetros ópticos y eléctricos de semiconductores y semimetales a escala nanométrica. En este trabajo se analiza las señales THz-TDS de las referencias y de las mediciones de las muestras. Se estudia la dependencia en frecuencia en el rango de THz, principalmente en las frecuencias de 0,1 a 2 THz, de las propiedades eléctricas y ópticas de nanoestructuras de materiales como el grafeno desde la transmisión y reflexión de un sistema propio de THz-TDS. La conductividad en DC no pudo ser directamente determinada, ya que la potencia disponible en THz decae abruptamente por debajo del nivel de ruido para bajas frecuencias. Los parámetros electrónicos y ópticos dependientes de la frecuencia son ruidosos debido al poco espesor de las láminas en comparación con los gruesos sustratos y también a la limitada sensibilidad del sistema THz-TDS por encima de 1,5 THz. En esta tesis se obtiene, por primera vez, la caracterización y el análisis espectroscópico de muestras como el grafeno depositado sobre un sustrato de cuarzo, no únicamente en el rango de THz sino también en frecuencia cero, esto es, en DC así como en la región del infrarrojo lejano. Los valores de conductividad de tan frágiles muestras son extraídos a partir de medidas sin contacto a frecuencias de THz mediante elaborados modelos de Drude y no-Drude que se ajustan a los datos experimentales, proveyéndonos de información de la física y la conductividad eléctrica de dichos materiales. El transporte, el scattering y la densidad de portadores cercana al punto de Dirac del grafeno y nanoestructuras de carbono son calculadas combinando las medidas en THZ con los modelos de Drude/no-Drude de la conductividad. Este procedimiento es validado mediante la concordancia de la conductividad DC extraída de las medidas de THz con las medidas clásicas de contacto en cuatro puntos a nivel micrométrico. Las características extrapoladas a partir de medidas de THz nos permiten predecir la frecuencia de corte de dichos materiales antes de ser utilizados en dispositivos optoelectrónicos. Esta tesis presenta una aplicación comercialmente relevante de técnicas y análisis THz-TDS sin contacto para la caracterización eléctrica de semiconductores a escala nanométrica y polímeros con alta movilidad en la nueva generación de dispositivos optoelectrónicos., This Ph.D. project was partially financed by the project (MITEPHO, 238393 ITN) Microwave and TErahertz PHOtonic under the European Commission. I have also received financial support for an extra year from the project (OILTEBIA, 317526 ITN) Optical Imaging and Laser TEchniques for BIomedical Applications funded by the European Commission., Programa Oficial de Doctorado en Ingeniería Eléctrica, Electrónica y Automática, Presidente: Ramón Gonzalo García.- Secretario: Guillermo Carpintero del Barrio.- Vocal: Yahya Moubarak Meziani
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publicación Artículo científico (JournalArticle)

Optoacoustic response of gold nanorods in soft phantoms using high-power diode laser assemblies at 870 and 905 nm

  • Leggio, Luca
  • Gawali, Sandeep Babu
  • Gallego Cabo, Daniel
  • Rodríguez Hervás, Sergio
  • Sánchez Rodas, Miguel
  • Carpintero del Barrio, Guillermo
  • Lamela Rivera, Horacio
In the present paper we show the optoacoustic (OA) response of two solutions of gold nanorods dispersed in distilled water (0.8 mg/ml) and hosted in tissue-like phantoms by using small arrays of HPDLs at 870 and 905 nm as excitation sources. The HPDLs are coupled to a 7-to-1 optical fiber bundle with output diameter of 675 mu m. Each solution of gold nanorods exhibits an absorption peak close to the operating wavelength, i.e. similar to 860 nm and similar to 900 nm, respectively, to optimize the generation of OA signals. The phantoms are made of agar, intralipid and hemoglobin to simulate a soft biological tissue with reduced properties of scattering. Three 3-mm diameter tubes done in the phantoms at different depths (0.9 cm, 1.8 cm, and 2.7 cm) have been filled with gold nanorods. In this way, OA signals with appreciable SNR are generated at different depths in the phantoms. The high OA response exhibited by gold nanorods suggests their application in OA spectroscopy as exogenous contrast agents to detect and monitor emerging diseases like metastasis and arteriosclerotic plaques., This research is part of OILTEBIA project (Optical Imaging and Laser TEchniques for BIomedical Applications), whch is an Initial Training Network (ITN) funded by the European Community's Seventh Framework Programme, Grant Agreement Number 317526.
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publicación Artículo científico (JournalArticle)

Phase-Retrieved Tomography enables Mesoscopic imaging of Opaque Tumor Spheroids

  • Ancora, Daniele
  • Di Battista, Diego
  • Giasafki, Georgia
  • Psycharakis, Stylianos E.
  • Liapis, Evangelos
  • Ripoll Lorenzo, Jorge
  • Zacharakis, Giannis
We present a new Phase-Retrieved Tomography (PRT) method to radically improve mesoscopic imaging at regimes beyond one transport mean-free-path and achieve high resolution, uniformly throughout the volume of opaque samples. The method exploits multi-view acquisition in a hybrid Selective Plane Illumination Microscope (SPIM) and Optical Projection Tomography (OPT) setup and a three-dimensional Gerchberg-Saxton phase-retrieval algorithm applied in 3D through the autocorrelation sinogram. We have successfully applied this innovative protocol to image optically dense 3D cell cultures in the form of tumor spheroids, highly versatile models to study cancer behavior and response to chemotherapy. We have thus achieved a significant improvement of resolution in depths not yet accessible with the currently used methods in SPIM/OPT, while overcoming all registration and alignment problems inherent to these techniques., This work was supported by the grants "Skin-DOCTor" (1778) implemented under the "ARISTEIA" Action of the "Operational Programme Education and Lifelong Learning" co-funded by the European Social Fund (ESF) and National Resources, the EU Marie Curie ITN "OILTEBIA" PITN-GA-2012-317526 and the H2020 Laserlab Europe (EC-GA 654148). J.R. acknowledges support from the EC-FP7-CIG grant HIGH-THROUGHPUT TOMO and MINECO grant FIS2016-77892-R. The Authors also acknowledge support from the Institute of Molecular Biology and Biotechnology of the Foundation for Research and Technology - Hellas for the use of the cell culture facilities.
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publicación Artículo científico (JournalArticle)

Beam Profile Improvement of a High-Power Diode Laser Stack for Optoacoustic Applications

  • Sánchez Rodas, Miguel
  • Rodríguez Hervás, Sergio
  • Leggio, Luca
  • Gawali, Sandeep Babu
  • Gallego Cabo, Daniel
  • Lamela Rivera, Horacio
Selected papers from Third Conference on Photoacoustic and Photothermal Theory and Applications., Recent advances in high-power diode lasers (HPDLs) technology allow their use as potential sources for optoacoustic (OA) applications, due to their high repetition rates (a few kHz), low costs and sizes. However, some OA applications require pulse energies in the order of mJ that cannot be provided by the only HPDLs (several mu J). The employment of diode laser bars (DLBs) and stacks (DLSs) significantly increases the energy per pulse up to several mJ, but they require more optical elements for collimation in fast and slow axes. In this work, we show an 808 nm DLS emitting optical nanosecond pulses with currents of similar to 200 A and supplied by a customized current driver. We only collimate the beam in the fast axis by disposing the core of 200 mu m optical fibers as collimating lenses along each bar of the stack, and we discuss the improvement of the beam profile. The results demonstrate that the beam profile is notably improved with the optical fiber lenses, and a 6.4 mm x 4.3 mm light spot is obtained by using a conventional focusing lens. Measurements report a total energy per pulse of 630 mu J in the spot, considering a pulse width of 850 ns and a repetition rate of 1 kHz. Finally, we focus the light spot into an absorbing inclusion (graphene oxide) hosted in a semi-transparent phantom to generate and detect high OA signals (similar to 355 mV(pp)). The results achieved demonstrate the capability of our DLS system to be applied in multispectral OA systems with final application in OA endoscopy and microscopy., A special acknowledgment has to be addressed to the ESA for the DLS provided. This research is part of OILTEBIA project (Optical Imaging and Laser TEchniques for BIomedical Applications), which is an Initial Training Network (ITN) funded by the European Community Seventh Framework Programme, Grant Agreement Number 317526.
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

In vivo, non-invasive characterization of human bone by hybrid broadband (600-1200 nm) diffuse optical and correlation spectroscopies

  • Konugolu Venkata Sekar, Sanathana
  • Pagliazzi, Marco
  • Negredo Puigmal, Eugènia
  • Martelli, Fabrizio
  • Farina, Andrea
  • Dalla Mora, Alberto
  • Lindner, Claus
  • Farzam, Parisa
  • Pérez Álvarez, Nuria|||0000-0001-6582-1553
  • Puig, Jordi
  • Taroni, Paola
  • Pifferi, Antonio
  • Durduran, Turgut
Non-invasive in vivo diffuse optical characterization of human bone opens a new possibility of diagnosing bone related pathologies. We present an in vivo characterization performed on seventeen healthy subjects at six different superficial bone locations: radius distal, radius proximal, ulna distal, ulna proximal, trochanter and calcaneus. A tailored diffuse optical protocol for high penetration depth combined with the rather superficial nature of considered tissues ensured the effective probing of the bone tissue. Measurements were performed using a broadband system for Time-Resolved Diffuse Optical Spectroscopy (TRS) to assess mean absorption and reduced scattering spectra in the 600–1200 nm range and Diffuse Correlation Spectroscopy (DCS) to monitor microvascular blood flow. Significant variations among tissue constituents were found between different locations; with radius distal rich of collagen, suggesting it as a prominent location for bone related measurements, and calcaneus bone having highest blood flow among the body locations being considered. By using TRS and DCS together, we are able to probe the perfusion and oxygen consumption of the tissue without any contrast agents. Therefore, we predict that these methods will be able to evaluate the impairment of the oxygen metabolism of the bone at the point-of-care., Peer Reviewed
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

In vivo, non-invasive characterization of human bone by hybrid broadband (600-1200 nm) diffuse optical and correlation spectroscopies

  • Konugolu Venkata Sekar, Sanathana
  • Pagliazzi, Marco
  • Negredo Puigmal, Eugènia
  • Martelli, Fabrizio
  • Farina, Andrea
  • Dalla Mora, Alberto
  • Lindner, Claus
  • Farzam, Parisa
  • Pérez Álvarez, Nuria
  • Puig, Jordi
  • Taroni, Paola
  • Pifferi, Antonio
  • Durduran, Turgut
Non-invasive in vivo diffuse optical characterization of human bone opens a new possibility of diagnosing bone related pathologies. We present an in vivo characterization performed on seventeen healthy subjects at six different superficial bone locations: radius distal, radius proximal, ulna distal, ulna proximal, trochanter and calcaneus. A tailored diffuse optical protocol for high penetration depth combined with the rather superficial nature of considered tissues ensured the effective probing of the bone tissue. Measurements were performed using a broadband system for Time-Resolved Diffuse Optical Spectroscopy (TRS) to assess mean absorption and reduced scattering spectra in the 600–1200 nm range and Diffuse Correlation Spectroscopy (DCS) to monitor microvascular blood flow. Significant variations among tissue constituents were found between different locations; with radius distal rich of collagen, suggesting it as a prominent location for bone related measurements, and calcaneus bone having highest blood flow among the body locations being considered. By using TRS and DCS together, we are able to probe the perfusion and oxygen consumption of the tissue without any contrast agents. Therefore, we predict that these methods will be able to evaluate the impairment of the oxygen metabolism of the bone at the point-of-care., Peer Reviewed, Postprint (published version)
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

In Vivo, Non-Invasive Characterization of Human Bone by Hybrid Broadband (600-1200 nm) Diffuse Optical and Correlation Spectroscopies

  • Konugolu Venkata Sekar, Sanathana|||0000-0003-0912-1282
  • Pagliazzi, Marco
  • Negredo Puigmal, Eugènia|||0000-0001-5298-1734
  • Martelli, Fabrizio
  • Farina, Andrea
  • Dalla Mora, Alberto
  • Lindner, Claus|||0000-0002-9878-037X
  • Farzam, Parisa
  • Pérez-Álvarez, Núria|||0000-0001-6582-1553
  • Puig, Jordi|||0000-0002-4075-0346
  • Taroni, Paola
  • Pifferi, Antonio
  • Durduran, Turgut|||0000-0001-5838-1027
Non-invasive in vivo diffuse optical characterization of human bone opens a new possibility of diagnosing bone related pathologies. We present an in vivo characterization performed on seventeen healthy subjects at six different superficial bone locations: radius distal, radius proximal, ulna distal, ulna proximal, trochanter and calcaneus. A tailored diffuse optical protocol for high penetration depth combined with the rather superficial nature of considered tissues ensured the effective probing of the bone tissue. Measurements were performed using a broadband system for Time-Resolved Diffuse Optical Spectroscopy (TRS) to assess mean absorption and reduced scattering spectra in the 600-1200 nm range and Diffuse Correlation Spectroscopy (DCS) to monitor microvascular blood flow. Significant variations among tissue constituents were found between different locations; with radius distal rich of collagen, suggesting it as a prominent location for bone related measurements, and calcaneus bone having highest blood flow among the body locations being considered. By using TRS and DCS together, we are able to probe the perfusion and oxygen consumption of the tissue without any contrast agents. Therefore, we predict that these methods will be able to evaluate the impairment of the oxygen metabolism of the bone at the point-of-care.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Blood flow response to orthostatic challenge identifies signatures of the failure of static cerebral autoregulation in patients with cerebrovascular disease

  • Gregori-Pla, Clara|||0000-0002-6623-0031
  • Mesquita, Rickson C.
  • Favilla, Christopher G.
  • Busch, David R.
  • Blanco, Igor|||0000-0001-7636-1177
  • Zirak, Peyman|||0000-0002-0331-6292
  • Frisk, Lisa Kobayashi
  • Avtzi, Stella|||0000-0002-8893-3969
  • Maruccia, Federica|||0000-0002-3774-7875
  • Giacalone, Giacomo
  • Cotta, Gianluca
  • Camps-Renom, Pol|||0000-0001-6587-6271
  • Mullen, Michael T.
  • Martí-Fàbregas, Joan|||0000-0001-9229-8649
  • Prats Sánchez, Luis Antonio|||0000-0002-3192-4631
  • Martínez-Domeño, Alejandro|||0000-0002-9933-3192
  • Kasner, Scott E.
  • Greenberg, Joel H.
  • Zhou, Chao
  • Edlow, Brian L.
  • Putt, Mary E.
  • Detre, John A.
  • Yodh, Arjun G.
  • Durduran, Turgut|||0000-0001-5838-1027
  • Delgado Mederos, Raquel|||0000-0003-3737-7226
The cortical microvascular cerebral blood flow response (CBF) to different changes in head-of-bed (HOB) position has been shown to be altered in acute ischemic stroke (AIS) by diffuse correlation spectroscopy (DCS) technique. However, the relationship between these relative ΔCBF changes and associated systemic blood pressure changes has not been studied, even though blood pressure is a major driver of cerebral blood flow. Transcranial DCS data from four studies measuring bilateral frontal microvascular cerebral blood flow in healthy controls (n = 15), patients with asymptomatic severe internal carotid artery stenosis (ICA, n = 27), and patients with acute ischemic stroke (AIS, n = 72) were aggregated. DCS-measured CBF was measured in response to a short head-of-bed (HOB) position manipulation protocol (supine/elevated/supine, 5 min at each position). In a sub-group (AIS, n = 26; ICA, n = 14; control, n = 15), mean arterial pressure (MAP) was measured dynamically during the protocol. After elevated positioning, DCS CBF returned to baseline supine values in controls (p = 0.890) but not in patients with AIS (9.6% [6.0,13.3], mean 95% CI, p < 0.001) or ICA stenosis (8.6% [3.1,14.0], p = 0.003)). MAP in AIS patients did not return to baseline values (2.6 mmHg [0.5, 4.7], p = 0.018), but in ICA stenosis patients and controls did. Instead ipsilesional but not contralesional CBF was correlated with MAP (AIS 6.0%/mmHg [- 2.4,14.3], p = 0.038; ICA stenosis 11.0%/mmHg [2.4,19.5], p < 0.001). The observed associations between ipsilateral CBF and MAP suggest that short HOB position changes may elicit deficits in cerebral autoregulation in cerebrovascular disorders. Additional research is required to further characterize this phenomenon. The online version contains supplementary material available at 10.1186/s12883-021-02179-8.