Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 7
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Organ-Dedicated Molecular Imaging Systems

  • González Martínez, Antonio Javier
  • F Sánchez
  • Benlloch Baviera, Jose María|||0000-0001-6073-1436
[EN] In this review, we will cover both clinical and technical aspects of the advantages and disadvantages of organ specific (dedicated) molecular imaging (MI) systems, namely positron emission tomography (PET) and single photon emission computed tomography, including gamma cameras. This review will start with the introduction to the organ-dedicated MI systems. Thereafter, we will describe the differences and their advantages/disadvantages when compared with the standard large size scanners. We will review time evolution of dedicated systems, from first attempts to current scanners, and the ones that ended in clinical use. We will review later the state of the art of these systems for different organs, namely: breast, brain, heart, and prostate. We will also present the advantages offered by these systems as a function of the special application or field, such as in surgery, therapy assistance and assessment, etc. Their technological evolution will be introduced for each organ-based imager. Some of the advantages of dedicated devices are: higher sensitivity by placing the detectors closer to the organ, improved spatial resolution, better image contrast recovery (by reducing the noise from other organs), and also lower cost. Designing a complete ring-shaped dedicated PET scanner is sometimes difficult and limited angle tomography systems are preferable as they have more flexibility in placing the detectors around the body/organ. Examples of these geometries will be presented for breast, prostate and heart imaging. Recently achievable excellent time of flight capabilities below 300-ps full width at half of the maximum reduce significantly the impact of missing angles on the reconstructed images., This work was supported in part by the European Research Council through the European Union's Horizon 2020 Research and Innovation Program under Grant 695536, in part by the EU through the FP7 Program under Grant 603002, and in part by the Spanish Ministerio de Economia, Industria y Competitividad through PROSPET (DTS15/00152) funded by the Ministerio de Economia y Competitividad under Grant TEC2016-79884-C2-1-R.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Ensemble of neural networks for 3D position estimation in monolithic PET detectors

  • Iborra Carreres, Amadeo
  • González, A.
  • Bousse, A.
  • Visvikis, Dimitris
  • González Martínez, Antonio Javier
[EN] We propose an ensemble of multilayer feedforward neural networks to estimate the 3D position of photoelectric interactions in monolithic detectors. The ensemble is trained with data generated from optical Monte Carlo simulations only. The originality of our approach is to exploit simulations to obtain reference data, in combination with a variability reduction that the network ensembles offer, thus, removing the need of extensive per-detector calibration measurements. This procedure delivers an ensemble valid for any detector of the same design. We show the capability of the ensemble to solve the 3D positioning problem through testing four different detector designs with Monte Carlo data, measurements from physical detectors and reconstructed images from the MindView scanner. Network ensembles allow the detector to achieve a 2-2.4 mm FWHM, depending on its design, and the associated reconstructed images present improved SNR, CNR and SSIM when compared to those based on the MindView built-in positioning algorithm.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Pilot performance of a dedicated prostate PET suitable for diagnosis and biopsy guidance

  • Cañizares-Ledo, Gabriel
  • Gonzalez-Montoro, Andrea
  • Lamprou, Efthymios
  • Barrio, John
  • Hernandez, Liczandro
  • Torres, Irene
  • Sopena, Pablo
  • Vera-Donoso, Cesar D.
  • Bello, Pilar
  • Barbera, Julio
  • Freire-López-Fando, Marta
  • F Sánchez
  • Benlloch Baviera, Jose María|||0000-0001-6073-1436
  • Moliner Martínez, Laura
  • Vidal San Sebastian, Luis Fernando|||0000-0001-8852-8560
  • González Martínez, Antonio Javier
[EN] Background: Prostate cancer (PCa) represents one of the most common types of cancers facing the male population. Nowadays, to confirm PCa, systematic or multiparametric MRI-targeted transrectal or transperineal biopsies of the prostate are required. However, due to the lack of an accurate imaging technique capable to precisely locate cancerous cells in the prostate, ultrasound biopsies sample random parts of the prostate and, therefore, it is possible to miss regions where those cancerous cells are present. In spite of the improvement with multiparametric MRI, the low reproducibility of its reading undermines the specificity of the method. Recent development of prostatespecific radiotracers has grown the interest on using positron emission tomography (PET) scanners for this purpose, but technological improvements are still required (current scanners have resolutions in the range of 4¿5 mm). Results: The main goal of this work is to improve state-of-the-art PCa imaging and diagnosis. We have focused our efforts on the design of a novel prostate-dedicated PET scanner, named ProsPET. This system has small scanner dimensions defined by a ring of just 41 cm inner diameter. In this work, we report the design, implementation, and evaluation (both through simulations and real data) of the ProsPET scanner. We have been able to achieve < 2 mm resolution in reconstructed images and high sensitivity. In addition, we have included a comparison with the Philips Gemini-TF scanner, which is used for routine imaging of PCa patients. The ProsPET exhibits better contrast, especially for rod sizes as small as 4.5 mm in diameter. Finally, we also show the first reconstructed image of a PCa patient acquired with the ProsPET. Conclusions: We have designed and built a prostate specific PET system, with a small footprint and improved spatial resolution when compared to conventional whole-body PET scanners. The gamma ray impact within each detector block includes accurate DOI determination, correcting for the parallax error. The potential role of combined organdedicated prostate-specific membrane antigen (PSMA) PET and ultrasound devices, as a prebiopsy diagnostic tool, could be used to guide sampling of the most aggressive sites in the prostate., The work presented in this article has been partially funded by a research grant from the regional government of the Comunitat Valenciana (Spain), co-funded by the European Union ERDF funds (European Regional Development Fund) of the Comunitat Valenciana 2014-2020, with reference IDIFEDER/2018/032 (High-Performance Algorithms for the Modelling, Simulation and early Detection of diseases in Personalized Medicine). This project has also received funding from the European Research Council (ERC) under the European Union's Horizon 2020 research and innovation program (grant agreement No 695536). It has also been supported by the EU Grant 603002 under the FP7 program and by the Spanish Ministerio de Economia, Industria y Competitividad under Grant e and through PROSPET (DTS15/00152) funded by the Ministerio de Economia y Competitividad.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Performance Study of a Large Monolithic LYSO PET Detector With Accurate Photon DOI Using Retroreflector Layers

  • Gonzalez-Montoro, Andrea
  • Aguilar, Albert
  • Cañizares, Gabriel
  • Conde, Pablo
  • Hernández, Liczandro
  • Galasso, Matteo
  • Fabbri, Andrea
  • Vidal San Sebastian, Luis Fernando|||0000-0001-8852-8560
  • F Sánchez
  • Benlloch Baviera, Jose María|||0000-0001-6073-1436
  • González Martínez, Antonio Javier
[EN] Clinical and organ-dedicated PET systems typically require a high efficiency imposing the use of thick scintillators, normally through crystal arrays. To provide depth of interaction (DOI) information, two or more layers are sometimes mounted in the staggered or phoswich approach. In this paper, we are proposing an alternative using thick and large monolithic crystals. We have tested two surface treatments for a 50 mm x 50 mm x 20 mm LYSO block. We provide data in this paper as close as 5 mm to the lateral walls. We left those walls black painted and the exit face coupled to the photosensor (12 x 12 SiPM array) polished. The entrance face was: 1) black painted or 2) coupled to a retroreflector (RR) layer. These configurations keep a good DOI linearity and, on average, reached 4 mm DOI resolution, measured as the full width at half of the maximum. Approaches using RR layers return constant and good energy resolutions nearing 12%, compared to a range of 15%-16% in the case of totally black painted blocks. The best result concerning the detector spatial resolution was obtained when one of the smallest RR was used (120 um corner cube size), being 1.7 mm at the entrance crystal layer and 0.7 mm in the layer closest to the photosensor. These values worsen at least 30% for the black treatment case., This work was supported in part by the EU FP7 program under Grant 603002, in part by the Spanish Plan Nacional de Investigacion Cientifica, Desarrollo e Innovacion Tecnologica under Grant TEC 2013-48036-C3-1-R, and in part by the Valencian Local Government under Grant PROMETEOII/2013/010 and Grant ISIC 2011/013. The work of A. J. Gonzalez was supported by the CSIC through the Ramon y Cajal modality.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

The MINDVIEW project: First results

  • Benlloch Baviera, Jose María|||0000-0001-6073-1436
  • González Martínez, Antonio Javier
  • Pani, R.
  • Preziosi, Enrico
  • Jackson, C.
  • Murphy, J.
  • Barbera Ballester, Julio
  • Correcher Salvador, Carlos
  • Aussenhofer, Sebastian
  • Gareis, D.
  • Visvikis, Dimitris
  • Bert, J.
  • Langstrom, B.
  • Farde, Lars
  • Toth, M.
  • Haggkvist, J.
  • Caixeta, F.
  • Kullander, K.
  • Somlai-Schweiger, I.
  • Schwaiger, Markus
[EN] We present the first results of the MINDVIEW project. An innovative imaging system for the human brain examination, allowing simultaneous acquisition of PET/MRI images, has been designed and constructed. It consists of a high sensitivity and high resolution PET scanner integrated in a novel, head-dedicated, radio frequency coil for a 3T MRI scanner. Preliminary measurements from the PET scanner show sensitivity 3 times higher than state-of-the-art PET systems that will allow safe repeated studies on the same patient. The achieved spatial resolution, close to 1 mm, will enable differentiation of relevant brain structures for schizophrenia. A cost-effective and simple method of radiopharmaceutical production from C-11-carbon monoxide and a mini-clean room has been demonstrated. It has been shown that C-11-raclopride has higher binding potential in a new VAAT null mutant mouse model of schizophrenia compared to wild type control animals. A significant reduction in TSPO binding has been found in gray matter in a small sample of drug-naive, first episode psychosis patients, suggesting a reduced number or an altered function of immune cells in brain at early stage schizophrenia. (c) 2018 Elsevier Masson SAS. All rights reserved., This project is funded by EU grant FP7-HEALTH-F2-2013-603002.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Novel method to measure the intrinsic spatial resolution in PET detectors based on monolithic crystals

  • González, A.
  • Bruyndonckx, Peter
  • Cañizares-Ledo, Gabriel
  • F Sánchez
  • Benlloch Baviera, Jose María|||0000-0001-6073-1436
  • González Martínez, Antonio Javier
[EN] The main aim of this work is to provide a method to retrieve the intrinsic spatial resolution of a gamma-ray detector block based on monolithic crystals within an assembled scanner. This method consists on a discrimination of the data using a software collimation process. The results are compared with an alternative method of separating two detector blocks far enough to produce a "virtual" source collimation due to the geometric constraints on the allowed coincidence event angles. A theoretical model has been deduced to fit the measured light distribution profiles, allowing estimating the detector intrinsic spatial resolution. The detector intrinsic spatial resolution is expected to follow a Gaussian distribution and the positron-emitter source shape, given the small size of a Na-22 source with 0.25 mm in diameter, can be assumed to follow a Lorentzian profile. However, the collimation of the data modifies the source shape that is no longer a pure Lorentzian distribution. Therefore, the model is based on the convolution of a Gaussian shaped distribution (contribution of the detector) and a modified Lorentzian distribution (contribution of the collimated source profile) that takes into account the collimation effect. Three LYSO crystals geometries have been studied in the present work, namely a 10 mm thick trapezoidal monolithic block, and two rectangular monolithic blocks with thicknesses of 15 mm and 20 mm, respectively. All the blocks have size dimensions of 50 mm x 50 mm. The experimental results yielded an intrinsic detector spatial resolution of 0.64 +/- 0.02 mm, 0.82 +/- 0.02 and 1.07 +/- 0.03 mm, for the 10 mm, 15 mm and 20 mm thick blocks, respectively, when the source was placed at the center of the detector. The detector intrinsic spatial resolution was moreover evaluated across one of the axis of each crystal. These values worsen to an average value of 0.68 +/- 0.04 mm, 0.90 +/- 0.14 and 1.29 +/- 0.19 mm, respectively, when the whole crystal size is considered, as expected. These tests show an accurate method to determine the intrinsic spatial resolution of monolithic-based detector blocks, once assembled in the PET system., This project has received funding from the European Research Council, Spain (ERC) under the European Union's Horizon 2020 research and innovation program (grant agreement No 695536). It has also been supported by the EU, Spain Grant 603002 under the FP7 program, and by the Spanish Ministerio de Economia, Industria y Competitividad under Grant TEC2016-79884-C2-1-R and through PROSPET (DTS15/00152) funded by the Ministerio de Economia y Competitividad, Spain.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Pilot performance of a dedicated prostate PET suitable for diagnosis and biopsy guidance

  • Cañizares, Gabriel
  • González Montoro, Andrea
  • Freire, Marta
  • Lamprou, Efthymios
  • Barrio Toala, J.
  • Sánchez, Filomeno
  • Benlloch Baviera, José María
  • Hernandez, Liczandro
  • Moliner, Laura
  • Vidal, Luis F.
  • Torres, Irene
  • Sopena, Pablo
  • Vera Donoso, César David
  • Bello, Pilar
  • Barberá, Julio
  • González Martínez, Antonio Javier
[Background] Prostate cancer (PCa) represents one of the most common types of cancers facing the male population. Nowadays, to confirm PCa, systematic or multiparametric MRI-targeted transrectal or transperineal biopsies of the prostate are required. However, due to the lack of an accurate imaging technique capable to precisely locate cancerous cells in the prostate, ultrasound biopsies sample random parts of the prostate and, therefore, it is possible to miss regions where those cancerous cells are present. In spite of the improvement with multiparametric MRI, the low reproducibility of its reading undermines the specificity of the method. Recent development of prostate-specific radiotracers has grown the interest on using positron emission tomography (PET) scanners for this purpose, but technological improvements are still required (current scanners have resolutions in the range of 4–5 mm)., [Results] The main goal of this work is to improve state-of-the-art PCa imaging and diagnosis. We have focused our efforts on the design of a novel prostate-dedicated PET scanner, named ProsPET. This system has small scanner dimensions defined by a ring of just 41 cm inner diameter. In this work, we report the design, implementation, and evaluation (both through simulations and real data) of the ProsPET scanner. We have been able to achieve < 2 mm resolution in reconstructed images and high sensitivity. In addition, we have included a comparison with the Philips Gemini-TF scanner, which is used for routine imaging of PCa patients. The ProsPET exhibits better contrast, especially for rod sizes as small as 4.5 mm in diameter. Finally, we also show the first reconstructed image of a PCa patient acquired with the ProsPET., [Conclusions] We have designed and built a prostate specific PET system, with a small footprint and improved spatial resolution when compared to conventional whole-body PET scanners. The gamma ray impact within each detector block includes accurate DOI determination, correcting for the parallax error. The potential role of combined organ-dedicated prostate-specific membrane antigen (PSMA) PET and ultrasound devices, as a prebiopsy diagnostic tool, could be used to guide sampling of the most aggressive sites in the prostate., The work presented in this article has been partially funded by a research grant from the regional government of the Comunitat Valenciana (Spain), co-funded by the European Union ERDF funds (European Regional Development Fund) of the Comunitat Valenciana 2014-2020, with reference IDIFEDER/2018/032 (High-Performance Algorithms for the Modelling, Simulation and early Detection of diseases in Personalized Medicine). This project has also received funding from the European Research Council (ERC) under the European Union’s Horizon 2020 research and innovation program (grant agreement No 695536). It has also been supported by the EU Grant 603002 under the FP7 program and by the Spanish Ministerio de Economía, Industria y Competitividad under Grant e and through PROSPET (DTS15/00152) funded by the Ministerio de Economia y Competitividad., Peer reviewed