Nanophotonic interferometric immunosensor for label-free and real-time monitoring of Irgarol 1051 in sea water

  • Chocarro Ruiz, Blanca
  • Lechuga, Laura M.
Resumen del trabajo presentado al BRAAVOO Marine Biosensors Workshop, celebrado en Villars-sur-Ollon (Gryon-Suiza) del 24 al 25 de noviembre de 2016., Every year large quantities of wastes and pollutants are dumped in the sea contributing to a slow but constant degradation of the marine water quality. Conventional analytical methodologies are sensitive and selective tools for the sea quality control but they operate only at laboratory settings. Bringing the monitoring tools directly to the contaminated place can result in cost and time savings. In the frame of the BRAAVOO project, we are developing a nanoimmunosensor module for the on-site analysis of sea pollutants. One of these pollutants is Irgarol 1051, a commonly used antifouling paint for marine vessels. Because of its biocidal effect, its presence in the marine environment has a negative impact on marine organisms like corals. We are developing a bimodal waveguide interferometer (BiMW) nano-immunosensor for real-time and label-free detection of Irgarol 1051. The detection is based on a competitive inhibition format assay using a hapten with a similar structure to Irgarol, but with a carboxylic group which can be covalently attached to the sensor surface. Results show limits of detection of few ng/L and the stability of the sensor surface up to 30 measure-regeneration cycles with sea water samples. Each measure-regeneration cycle takes 15 minutes and the sample does not require any pre-treatment., This work has been funded by the 7FP (EU, BRAAVOO Grant Agreement No 614010). ICN2 acknowledges support from the Severo Ochoa Program (MINECO, Grant SEV-2013-0295)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Alcanivorax borkumensis produces an extracellular siderophore in iron-limitation condition maintaining the hydrocarbon-degradation efficiency

  • Denaro, Renata
  • Crisafi, Francesca
  • Russo, D.
  • Genovese, María
  • Messina, Enzo
  • Genovese, L.
  • Carbone, M.
  • Ciavatta, M. L.
  • Ferrer, Manuel
  • Golyshin, Peter N.
  • Yakimov, Michail M.
Obligate marine hydrocarbonoclastic bacteria possess genetic and physiological features to use hydrocarbons as sole source of carbon and to compete for the uptake of nutrients in usually nutrient-depleted marine habitats. In the present work we have studied the siderophore-based iron uptake systems in Alcanivorax borkumensis SK2 and their functioning during biodegradation of an aliphatic hydrocarbon, tetradecane, under iron limitation conditions. The antiSMASH analysis of SK2 genome revealed the presence of two different putative operons of siderophore synthetases. Search for the predicted core structures indicated that one siderophore is clearly affiliated to the family of complex oligopeptidic siderophores possessing an Orn-Ser-Orn carboxyl motif whereas the second one is likely to belong to the family of SA (salicylic acid)–based siderophores. Analyzing the supernatant of SK2 culture, an extracellular siderophore was identified and its structure was resolved. Thus, along with the recently described membrane-associated amphiphilic tetrapeptidic siderophore amphibactin, strain SK2 additionally produces an extracellular type of iron-chelating molecule with structural similarity to pseudomonins. Comparative Q-PCR analysis of siderophore synthetases demonstrated their significant up-regulation in iron-depleted medium. Different expression patterns were recorded for two operons during the early and late exponential phases of growth, suggesting a different function of these two siderophores under iron-depleted conditions., This work was funded by the European Community Projects KILL-SPILL (FP7-KBBE-2012.3.5-01-4 Project 312139 “Integrated Biotechnological Solutions for Combating Marine Oil Spills”) and BRAAVOO (FP7-KBBE OCEAN 2013.1 “Biosensors, Reporters and Algal Autonomous Vessels for Ocean Operation”)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Full integration of photonic nanoimmunosensors in portable platforms for on-line monitoring of ocean pollutants

  • Fernández Gavela, Adrián
  • Herranz, Sonia
  • Chocarro Ruiz, Blanca
  • Falke, Floris
  • Schreuder, Erik
  • Leeuwis, Henk
  • Heideman, René G.
  • Lechuga, Laura M.
We have developed a photonic nano-immunosensor platform for the on-site analysis of harmful organic ocean pollutants, intended to be allocated in stand-alone buoys. The main aim is bringing the monitoring tools directly to the contaminated place, resulting in cost and time savings as compared to the standard analytical techniques. As sensor we have employed an integrated asymmetric Mach-Zehnder interferometer (aMZI) of micro/nano dimensions, based on silicon photonic technology. In order to obtain a multiplexed system, a four-channel microfluidic cell has been designed, manufactured and incorporated in the miniaturized sensor. Additionally, a microfluidic delivery module enabling automatic sample analysis has been designed, evaluated and assembled. Moreover, we have implemented the optical interconnections of the sensor chip by fiber optics, as well the electronics and the required software and data processing. Pollutant detection is based on a competitive immunoassay using bioreceptors previously biofunctionalized on the aMZI sensor arms and incubation with a specific antibody. As proof of concept, two types of pollutants have been analysed: the biocide Irgarol 1051, and the antibiotic Tetracycline. Results show limits of detection in the range of few ng/mL, accomplished the European legislation., This work has been funded by the 7FP (EU, BRAAVOO Grant Agreement No 614010. ICN2 acknowledges support of the Spanish MINECO through the Severo Ochoa Centers of Excellence Program under Grant SEV-2013-0295. The ICN2 is funded by the CERCA programme/Generalitat de Catalunya., Peer reviewed
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

An automated optofluidic biosensor platform combining interferometric sensors and injection moulded microfluidics

  • Szydzik, C.
  • Fernandez-Gavela, Adrian|||0000-0002-4562-1308
  • Herranz, Sonia|||0000-0001-7657-1203
  • Roccisano, J.
  • Knoerzer, M.
  • Thurgood, P.
  • Khoshmanesh, K.
  • Mitchell, Arnan
  • Lechuga, Laura M|||0000-0001-5187-5358
A primary limitation preventing practical implementation of photonic biosensors within point-of-care platforms is their integration with fluidic automation subsystems. For most diagnostic applications, photonic biosensors require complex fluid handling protocols; this is especially prominent in the case of competitive immunoassays, commonly used for detection of low-concentration, low-molecular weight biomarkers. For this reason, complex automated microfluidic systems are needed to realise the full point-of-care potential of photonic biosensors. To fulfil this requirement, we propose an on-chip valve-based microfluidic automation module, capable of automating such complex fluid handling. This module is realised through application of a PDMS injection moulding fabrication technique, recently described in our previous work, which enables practical fabrication of normally closed pneumatically actuated elastomeric valves. In this work, these valves are configured to achieve multiplexed reagent addressing for an on-chip diaphragm pump, providing the sample and reagent processing capabilities required for automation of cyclic competitive immunoassays. Application of this technique simplifies fabrication and introduces the potential for mass production, bringing point-of-care integration of complex automated microfluidics into the realm of practicality. This module is integrated with a highly sensitive, label-free bimodal waveguide photonic biosensor, and is demonstrated in the context of a proof-of-concept biosensing assay, detecting the low-molecular weight antibiotic tetracycline.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Nanophotonic label-free biosensors for environmental monitoring

  • Chocarro Ruiz, Blanca|||0000-0003-3835-9046
  • Fernandez-Gavela, Adrian|||0000-0002-4562-1308
  • Herranz, Sonia|||0000-0001-7657-1203
  • Lechuga, Laura M|||0000-0001-5187-5358
The field of environmental monitoring has experienced a substantial progress in the last years but still the on-site control of contaminants is an elusive problem. In addition, the growing number of pollutant sources is accompanied by an increasing need of having efficient early warning systems. Several years ago biosensor devices emerged as promising environmental monitoring tools, but their level of miniaturization and their fully operation outside the laboratory prevented their use on-site. In the last period, nanophotonic biosensors based on evanescent sensing have emerged as an outstanding choice for portable point-of-care diagnosis thanks to their capability, among others, of miniaturization, multiplexing, label-free detection and integration in lab-on-chip platforms. This review covers the most relevant nanophotonic biosensors which have been proposed (including interferometric waveguides, grating-couplers, microcavity resonators, photonic crystals and localized surface plasmon resonance sensors) and their recent application for environmental surveillance.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Interferometric nanoimmunosensor for label-free and real-time monitoring of Irgarol 1051 in seawater

  • Chocarro Ruiz, Blanca|||0000-0003-3835-9046
  • Herranz, Sonia|||0000-0001-7657-1203
  • Fernandez-Gavela, Adrian|||0000-0002-4562-1308
  • Sanchís, Josep
  • Farre, Marinella|||0000-0001-8391-6257
  • Marco, María Pilar|||0000-0002-4064-1668
  • Lechuga, Laura M|||0000-0001-5187-5358
An interferometric nanobiosensor for the specific and label-free detection of the pollutant Irgarol 1051 directly in seawater has been settled. Due to the low molecular weight of Irgarol pollutant and its expected low concentration in seawater, the sensor is based on a competitive inhibition immunoassay. Parameters as surface biofunctionalization, concentration of the selective antibody and regeneration conditions have been carefully evaluated. The optimized immunosensor shows a limit of detection of only 3 ng/L, well below the 16 ng/L set by the EU as the maximum allowable concentration in seawater. It can properly operate during 30 assay-regeneration cycles using the same sensor biosurface and with a time-to-result of only 20 min for each cycle. Moreover, the interferometric nanosensor is able to directly detect low concentrations of Irgarol 1051 in seawater without requiring sample pre-treatments and without showing any background signal due to sea matrix effect.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Full integration of photonic nanoimmunosensors in portable platforms for on-line monitoring of ocean pollutants

  • Fernandez-Gavela, Adrian|||0000-0002-4562-1308
  • Herranz, Sonia|||0000-0001-7657-1203
  • Chocarro Ruiz, Blanca|||0000-0003-3835-9046
  • Falke, Floris
  • Schreuder, Erik
  • Leeuwis, Henz
  • Heideman, René G.
  • Lechuga, Laura M|||0000-0001-5187-5358
We have developed a photonic nano-immunosensor platform for the on-site analysis of harmful organic ocean pollutants, intended to be allocated in stand-alone buoys. The main aim is bringing the monitoring tools directly to the contaminated place, resulting in cost and time savings as compared to the standard analytical techniques. As sensor we have employed an integrated asymmetric Mach-Zehnder interferometer (aMZI) of micro/nano dimensions, based on silicon photonic technology. In order to obtain a multiplexed system, a four-channel microfluidic cell has been designed, manufactured and incorporated in the miniaturized sensor. Additionally, a microfluidic delivery module enabling automatic sample analysis has been designed, evaluated and assembled. Moreover, we have implemented the optical interconnections of the sensor chip by fiber optics, as well the electronics and the required software and data processing. Pollutant detection is based on a competitive immunoassay using bioreceptors previously biofunctionalized on the aMZI sensor arms and incubation with a specific antibody. As proof of concept, two types of pollutants have been analysed: the biocide Irgarol 1051, and the antibiotic Tetracycline. Results show limits of detection in the range of few ng/mL, accomplished the European legislation.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Nanophotonic interferometric immunosensors for label-free and real-time monitoring of chemical contaminants in marine environment

  • Chocarro Ruiz, Blanca|||0000-0003-3835-9046
  • Herranz, Sonia|||0000-0001-7657-1203
  • Fernandez-Gavela, Adrian|||0000-0002-4562-1308
  • Lechuga, Laura M|||0000-0001-5187-5358
With the aim to prevent the oceans ecosystems degradation, there is an urgent need to develop portable sensing tools able to operate directly in the environment, avoiding the transportation of the ocean samples to analytical laboratories. To achieve this long-term objective, we describe here the work carried out to develop and characterize a multiplexed photonic immunosensor for the direct analysis of toxic chemical targets in marine samples. We have employed immunosensors based on photonic Bimodal Waveguide (BiMW) interferometric devices fabricated in silicon technologies combined with specific receptors and antibodies for the targeted chemical targets. Several procedures for the functionalization of the S₃iN₄ sensor surfaces have been evaluated based on wet silanization methods and further covalent receptor immobilization. The developed immunosensors, based on competitive inhibition assays, show LODs at μg/L or ng/L levels, depending on the analyzed chemical target.