Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 11
Encontrada(s) 1 página(s)

e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publicación Artículo científico (JournalArticle)

Single plane illumination microscopy for microfluidic device imaging

  • Gomez-Cruz, Clara
  • Laguna, Sonia
  • Bachiller, Ariadna
  • Quílez López, Cristina
  • Cañadas-Ortega, Marina
  • Albert-Smet, Ignacio
  • Ripoll Lorenzo, Jorge
  • Muñoz Barrutia, María Arrate
This article belongs to the Special Issue Microfluidics for Detection and Analysis., Three-dimensional imaging of live processes at a cellular level is a challenging task. It requires high-speed acquisition capabilities, low phototoxicity, and low mechanical disturbances. Three-dimensional imaging in microfluidic devices poses additional challenges as a deep penetration of the light source is required, along with a stationary setting, so the flows are not perturbed. Different types of fluorescence microscopy techniques have been used to address these limitations; particularly, confocal microscopy and light sheet fluorescence microscopy (LSFM). This manuscript proposes a novel architecture of a type of LSFM, single-plane illumination microscopy (SPIM). This custom-made microscope includes two mirror galvanometers to scan the sample vertically and reduce shadowing artifacts while avoiding unnecessary movement. In addition, two electro-tunable lenses fine-tune the focus position and reduce the scattering caused by the microfluidic devices. The microscope has been fully set up and characterized, achieving a resolution of 1.50 μ m in the x-y plane and 7.93 μ m in the z-direction. The proposed architecture has risen to the challenges posed when imaging microfluidic devices and live processes, as it can successfully acquire 3D volumetric images together with time-lapse recordings, and it is thus a suitable microscopic technique for live tracking miniaturized tissue and disease models., This work was partially supported by Ministerio de Ciencia, Innovación y Universidades, Agencia Estatal de Investigación, under Grants TEC2016-78052 (A.M.-B.) and PID2019-109820RB-I00 (A.M.-B.), MCIN/AEI/10.13039/501100011033/, co-finance by European Regional Development Fund (ERDF), "A way of making Europe." CGC acknowledges support from the Ministerio de Ciencia, Innovacion y Universidades, Spain (FPU20/01459). JR acknowledges funding from Ministerio de Economía y Competitividad (FIS2020-115088RB-I00) and Horizon 2020 Framework Programme (801347-SENSITIVE).
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publicación Artículo científico (JournalArticle)

Recent advances in optical tomography in low scattering media

  • Marcos Vidal, Asier
  • Ripoll Lorenzo, Jorge
Low scattering media is the best scenario for optical imaging in thick samples and deep tissue, as it allows to obtain high resolution images without suffering the limitations that the diffusion phenomenon imposes. The high contribution of ballistic light in this regime enabled the development of light sheet microscopy and optical projection tomography, two of the most common techniques nowadays in research laboratories. Their revolutionary approach and wide spectrum of applications and possibilities has lead to a frenetic rhythm of new works and techniques arising every year. The large amount of information available often overwhelms scientists and researchers trying to keep up to date with the last cutting edge advances of the field. This paper aims to give a brief review of the origins and fundamental aspects of these two techniques to focus on the most recent and yet non reviewed works. Apart from novel methods, this document also covers combined multimodal approaches and systems. To conclude, we put a spotlight on the important role that open-source microscopy systems play in the field, as they improve the accessibility to these techniques and promote collaborative networks across the optical imaging community.
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publicación Artículo científico (JournalArticle)

Multimodal imaging combining time-domain near-infrared optical tomography and continuous-wave fluorescence molecular tomography

  • Ren, Wuwei
  • Jiang, Jingjing
  • Di Costanzo Mata, Aldo
  • Kalyanov, Alexander
  • Ripoll Lorenzo, Jorge
  • Lindner, Scott
  • Charbon, Edoardo
  • Zhang, Chao
  • Rudin, Markus
  • Wolf, Martin
Fluorescence molecular tomography (FMT) emerges as a powerful non-invasive imaging tool with the ability to resolve fluorescence signals from sources located deep in living tissues. Yet, the accuracy of FMT reconstruction depends on the deviation of the assumed optical properties from the actual values. In this work, we improved the accuracy of the initial optical properties required for FMT using a new-generation time-domain (TD) near-infrared optical tomography (NIROT) system, which effectively decouples scattering and absorption coefficients. We proposed a multimodal paradigm combining TD-NIROT and continuous-wave (CW) FMT. Both numerical simulation and experiments were performed on a heterogeneous phantom containing a fluorescent inclusion. The results demonstrate significant improvement in the FMT reconstruction by taking the NIROT-derived optical properties as prior information. The multimodal method is attractive for preclinical studies and tumor diagnostics since both functional and molecular information can be obtained., Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung (159490, 178262); Horizon 2020 Framework Programme (801347); Ministerio de Economía y Competitividad (FIS2016-77892-R); Krebsforschung Schweiz (KFS-3732-08-2015)., Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung (159490, 178262); Horizon 2020 Framework Programme (801347); Ministerio de Economía y Competitividad (FIS2016-77892-R); Krebsforschung Schweiz (KFS-3732-08-2015).
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publicación Artículo científico (JournalArticle)

Qualitative disorder measurements from backscattering spectra through an optical fiber

  • Fernández Sánchez, Rafael
  • Marcos Vidal, Asier
  • Gallego, S.
  • Beléndez, A.
  • Desco Menéndez, Manuel
  • Ripoll Lorenzo, Jorge
In the processes related to the development of cancer, there are different genetic and epigenetic events involved that result in structural changes of the affected cells. In the early stages of the disease, these changes occur at the nanoscale, remaining undetectable by conventional light microscopy, due to diffraction-limited resolution (~250 - 550 nm). In this sense, a technique termed partial wave spectroscopy (PWS) allows the detection of these nanostructural changes by measuring a statistical parameter called disorder strength (Ld). PWS uses a combination of a tunable filter and a camera to acquire the backscattering spectra for each pixel on the image. In this paper, we study and validate the possibility of obtaining a qualitative measurement of the disorder using the spectrum of the averaged spatial information. Instead of using spatial information and measuring sequentially spectral ranges, we measure the backscattered signal gathered by an optical fiber by means of a spectrograph. This will allow this method to be applied in systems where it is not possible to acquire a complete high resolution image for many spectral bands, while significantly enhancing speed., Horizon 2020 Framework Programme (801347-SENSITIVE); Ministerio de Economía y Competitividad (FIS2016-77892-R); Conselleria d'Educació, Investigació, Cultura i Esport (APOSTD/2018/A/084); Comunidad de Madrid (S2017/BMD-3867 RENIM-CM); Ministerio de Ciencia, Innovación y Universidades (SEV-2015-0505).
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publicación Otros (Other)

Biomedical applications of tissue clearing and three-dimensional imaging in health and disease

  • Gómez Gaviro, María Victoria
  • Sanderson, Daniel
  • Ripoll Lorenzo, Jorge
  • Desco Menéndez, Manuel
Three-dimensional (3D) optical imaging techniques can expand our knowledge about physiological and pathological processes that cannot be fully understood with 2D approaches. Standard diagnostic tests frequently are not sufficient to unequivocally determine the presence of a pathological condition. Whole-organ optical imaging requires tissue transparency, which can be achieved by using tissue clearing procedures enabling deeper image acquisition and therefore making possible the analysis of large-scale biological tissue samples. Here, we review currently available clearing agents, methods, and their application in imaging of physiological or pathological conditions in different animal and human organs. We also compare different optical tissue clearing methods discussing their advantages and disadvantages and review the use of different 3D imaging techniques for the visualization and image acquisition of cleared tissues. The use of optical tissue clearing resources for large-scale biological tissues 3D imaging paves the way for future applications in translational and clinical research., This work was supported by Ministerio de Ciencia, Innovación y Universidades, ISCIII-FIS grants PI18/00462 co-financed by ERDF, European Union (FEDER) Funds from the European Commission, European Union,"A way of making Europe"; the CNIC is supported by the Ministerio de Ciencia, Innovación y Universidades y the Pro CNIC Foundation, Severo Ochoa Center ofExcellence (SEV-2015-0505), CIBER de Salud Mental(CIBERSAM), and COST-action CA16124. J.R. acknowledges funding from EU H2020 FET Open projectSENSITIVE, ID 801347, and Ministerio de Ciencia, Innovación y Universidades Grant FIS2016-77892-R. Allapplicable international, national, and/or institutional guidelines for the care and use of animals were fol-lowed. All procedures performed in studies involving animals were in accordance with the ethical standardsof the institution or practice at which the studies were conducted.
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publicación Artículo científico (JournalArticle)

Probing Field Cancerization in the Gastrointestinal Tract Using a Hybrid Raman and Partial Wave Spectroscopy Microscope

  • Kriukova, Elena
  • Mazurenka, Mikhail
  • Marcazzan, Sabrina
  • Tschurtschenthaler, Markus
  • Puppels, Gerwin
  • Glasl, Sarah
  • Saur, Dieter
  • Jesinghaus, Moritz
  • Pouliou, Marialena
  • Agelopoulos, Marios
  • Klinakis, Apostolos
  • Quante, Michael
  • Ripoll Lorenzo, Jorge
  • Ntziachristos, Vasilis
  • Gorpas, Dimitris
Field cancerization (FC) refers to spatially distributed premalignant tissue changes that lead to the appearance of local malignancy, and its detection can improve cancer screening. In this work, we employ combined Raman and partial wave spectroscopy (RS-PWS) to detect FC in gastroesophageal (L2-IL1B) and intestinal (Villin-Cre, Apcfl/wt) tumor mouse models. Using a hybrid RS-PWS microscope, we acquire both molecular and morphological information from macroscopically normal tumor-adjacent tissue and investigate the individual and combined performance of each modality. For data analysis, we use partial least-squares discriminant analysis (PLS-DA). In the normal tissue of L2-IL1B mice, we demonstrate a statistically significant increase (p less than 0.001) in Raman band intensities associated with free amino acids and a decrease in bands associated with lipids (p less than 0.005) and carotenoids (p less than 0.001) compared to healthy controls. Similarly, in the normal mucosa of Villin-Cre, Apcfl/wt mice, the intensities of RS bands associated with amino acids increase significantly (p less than 0.05) compared to controls, while the intensities of lipid-associated bands decrease significantly (p less than 0.05). Transcriptomic profiling using RNA-sequencing analysis on these samples identified a significant correlation between gene expression and optical findings. Moreover, we demonstrate that combining RS and PWS data further improves the significance of our classification results. When macroscopically normal tumor-adjacent tissue is compared with tissue from healthy controls, we observe that PWS increases the R2 of RS results by ~9% in L2-IL1B mice and ~5% in Villin-Cre, Apcfl/wt mice. Combining molecular RS with structural PWS information enhances the ability to detect precancerous changes and provides insights into tissue alterations during cancer development., This project has received funding from the European Union's Horizon 2020 research and innovation programme under grant agreement No. 801347 (SENSITIVE) and No. 862811 (DynAMic) and from the TranslaTUM Seed Fund 2024 (grant 24-2-GorTsc).
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publicación Artículo científico (JournalArticle)

Applications of light-sheet microscopy in microdevices

  • Albert Smet, Ignacio
  • Marcos Vidal, Asier
  • Vaquero López, Juan José
  • Desco Menéndez, Manuel
  • Muñoz Barrutia, María Arrate
  • Ripoll Lorenzo, Jorge
Light-sheet fluorescence microscopy (LSFM) has been present in cell biology laboratories for quite some time, mainly as custom-made systems, with imaging applications ranging from single cells (in the micrometer scale) to small organisms (in the millimeter scale). Such microscopes distinguish themselves for having very low phototoxicity levels and high spatial and temporal resolution, properties that make them ideal for a large range of applications. These include the study of cellular dynamics, in particular cellular motion which is essential to processes such as tumor metastasis and tissue development. Experimental setups make extensive use of microdevices (bioMEMS) that provide better control over the substrate environment than traditional cell culture experiments. For example, to mimic in vivo conditions, experiment biochemical dynamics, and trap, move or count cells. Microdevices provide a higher degree of empirical complexity but, so far, most have been designed to be imaged through wide-field or confocal microscopes. Nonetheless, the properties of LSFM render it ideal for 3D characterization of active cells. When working with microdevices, confocal microscopy is more widespread than LSFM even though it suffers from higher phototoxicity and slower acquisition speeds. It is sometimes possible to illuminate with a light-sheet microdevices designed for confocal microscopes. However, these bioMEMS must be redesigned to exploit the full potential of LSFM and image more frequently on a wider scale phenomena such as motion, traction, differentiation, and diffusion of molecules. The use of microdevices for LSFM has extended beyond cell tracking studies into experiments regarding cytometry, spheroid cultures and lab-on-a-chip automation., JR acknowledges funding from EU H2020 FET Open project SENSITIVE, ID 801347 and Spanish Ministry of Economy and Competitiveness (MINECO) Grant FIS2016-77892-R. AM-B acknowledges funding from the MINECO (TEC2013-48552-C2-1-R, TEC2015-73064-EXP, TEC2016-78052-R), Beca Leonardo a Investigadores y Creadores Culturales 2017, Fundacion BBVA and EU Open project SENSITIVE. The CNIC is supported by the Ministerio de Ciencia, Innovacion y Universidades and the Pro CNIC Foundation, and is a Severo Ochoa Center of Excellence (SEV-2015-0505).
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publicación Artículo científico (JournalArticle)

Nonlinearity of optoacoustic signals and a new contrast mechanism for imaging

  • Malekzadeh Najafabadi, Jaber
  • Prakash, Jaya
  • Razansky, Daniel
  • Ripoll Lorenzo, Jorge
  • Gujrati, Vipul
  • Ntziachristos, Vasilis
Optoacoustic signals behave nonlinearly at light fluences above a few mJ/cm2, which may affect the interpretation and quantification of measurements. It has been proposed that optoacoustic nonlinearity arises from the heat-induced formation of nanobubbles or changes in local thermo-physical parameters. However, such explanations are only valid at much higher fluences than typically used in biomedical optoacoustic imaging (> 20 mJ/cm2) or in the presence of materials with high absorption coefficients such as gold nanoparticles. We propose herein that electromagnetic permittivity changes in response to photon absorption are major source of optoacoustic signal nonlinearity at low fluences. We provide theoretical and experimental evidence that supports this postulation and show that optoacoustic pressure responses due to permittivity changes, which are function of thermally excited third-order nonlinear susceptibility, can explain the nonlinear behavior of the optoacoustic signal. Since different materials exhibit different thermally excited third-order nonlinear susceptibility, this property could function as a new contrast mechanism that can identify the sensitivity of a substance's dielectric constant to photon-induced temperature changes. Consequently, we propose an imaging method based on nonlinear optoacoustic signals that exploits this newly identified contrast mechanism. These findings may have far-reaching implications for improving the accuracy of optoacoustics and utilizing the proposed new contrast mechanism would advance our understanding of cellular and tissue functionality., This work was funded by the European Union under the 7th Framework Program grant agreement no 605162 (BERTI), the European Union's Horizon 2020 research and innovation programme under grant agreement no. 687866 (INNODERM) and no. 862811 (RSENSE), and the Deutsche Forschungsgemeinschaft (DFG) as part of the CRC 1123 (Z1). JR acknowledges funding from the European Commission grant agreement No 801347 (SENSITIVE), and Spanish Ministry of Economy and Competitiveness (MINECO) Grant FIS2016-77892-R. Jaya Prakash acknowledges the Alexander von Humboldt Postdoctoral Fellowship program. The authors appreciate the editing assistance of Robert Wilson, PhD and A. Chapin Rodríguez, PhD.
Repisalud
Publicación Artículo científico (JournalArticle)

Biomedical Applications of Tissue Clearing and Three-Dimensional Imaging in Health and Disease.

  • Gomez-Gaviro, Maria Victoria
  • Sanderson, Daniel
  • Ripoll, Jorge
  • Desco, Manuel
Three-dimensional (3D) optical imaging techniques can expand our knowledge about physiological and pathological processes that cannot be fully understood with 2D approaches. Standard diagnostic tests frequently are not sufficient to unequivocally determine the presence of a pathological condition. Whole-organ optical imaging requires tissue transparency, which can be achieved by using tissue clearing procedures enabling deeper image acquisition and therefore making possible the analysis of large-scale biological tissue samples. Here, we review currently available clearing agents, methods, and their application in imaging of physiological or pathological conditions in different animal and human organs. We also compare different optical tissue clearing methods discussing their advantages and disadvantages and review the use of different 3D imaging techniques for the visualization and image acquisition of cleared tissues. The use of optical tissue clearing resources for large-scale biological tissues 3D imaging paves the way for future applications in translational and clinical research.
Repisalud
Publicación Artículo científico (JournalArticle)

Applications of Light-Sheet Microscopy in Microdevices

  • Albert-Smet, Ignacio
  • Marcos-Vidal, Asier
  • Vaquero, Juan José
  • Desco, Manuel
  • Muñoz-Barrutia, Arrate
  • Ripoll, Jorge
Light-sheet fluorescence microscopy (LSFM) has been present in cell biology laboratories for quite some time, mainly as custom-made systems, with imaging applications ranging from single cells (in the micrometer scale) to small organisms (in the millimeter scale). Such microscopes distinguish themselves for having very low phototoxicity levels and high spatial and temporal resolution, properties that make them ideal for a large range of applications. These include the study of cellular dynamics, in particular cellular motion which is essential to processes such as tumor metastasis and tissue development. Experimental setups make extensive use of microdevices (bioMEMS) that provide better control over the substrate environment than traditional cell culture experiments. For example, to mimic in vivo conditions, experiment biochemical dynamics, and trap, move or count cells. Microdevices provide a higher degree of empirical complexity but, so far, most have been designed to be imaged through wide-field or confocal microscopes. Nonetheless, the properties of LSFM render it ideal for 3D characterization of active cells. When working with microdevices, confocal microscopy is more widespread than LSFM even though it suffers from higher phototoxicity and slower acquisition speeds. It is sometimes possible to illuminate with a light-sheet microdevices designed for confocal microscopes. However, these bioMEMS must be redesigned to exploit the full potential of LSFM and image more frequently on a wider scale phenomena such as motion, traction, differentiation, and diffusion of molecules. The use of microdevices for LSFM has extended beyond cell tracking studies into experiments regarding cytometry, spheroid cultures and lab-on-a-chip automation. Due to light-sheet microscopy being in its early stages, a setup of these characteristics demands some degree of optical expertise; and designing three-dimensional microdevices requires facilities, ingenuity, and experience in microfabrication. In this paper, we explore different approaches where light-sheet microscopy can achieve single-cell and subcellular resolution within microdevices, and provide a few pointers on how these experiments may be improved.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Qualitative disorder measurements from backscattering spectra through an optical fiber

  • Fernandez, Roberto
  • Marcos, Asier
  • Gallego, Sergi
  • Beléndez, Augusto
  • Desco, Manuel
  • Ripoll, Jorge
  • Beléndez, Augusto
  • Fernandez, Roberto|||/items/ca9b5808-d6e3-44da-a2b8-6ace83cf0a56
  • Gallego, Sergi|||/items/139b2e44-1c73-4762-beb6-b2bb46fd4e89
  • Beléndez, Augusto|||/items/1ea7a525-ee45-4792-bd9a-a54f76963120
In the processes related to the development of cancer, there are different genetic and epigenetic events involved that result in structural changes of the affected cells. In the early stages of the disease, these changes occur at the nanoscale, remaining undetectable by conventional light microscopy, due to diffraction-limited resolution (∼250 - 550 nm). In this sense, a technique termed partial wave spectroscopy (PWS) allows the detection of these nanostructural changes by measuring a statistical parameter called disorder strength (Ld). PWS uses a combination of a tunable filter and a camera to acquire the backscattering spectra for each pixel on the image. In this paper, we study and validate the possibility of obtaining a qualitative measurement of the disorder using the spectrum of the averaged spatial information. Instead of using spatial information and measuring sequentially spectral ranges, we measure the backscattered signal gathered by an optical fiber by means of a spectrograph. This will allow this method to be applied in systems where it is not possible to acquire a complete high resolution image for many spectral bands, while significantly enhancing speed.