El COVID-19, la normativa de ventilación y su impacto ambiental en las universidades en México

  • Valencia-Salazar, Iván|||0000-0002-5223-4218
  • Peñalvo-López, Elisa|||0000-0002-3143-822X
  • Montañana-Romeu, Joaquín|||0000-0003-3331-9205
  • León-Martínez, Vicente|||0000-0002-1906-371X
[EN] This paper analyses the increase in energy consumption caused by COVID-19 containment measures in university classrooms in Mexico, particularly in hot humid areas where the use of air conditioning units is required. The effect of ventilation on classroom temperature, student comfort and air conditioning equipment consumption are analysed., Queremos agradecer a GENERALITAT VALENCIANA y a la Comisión Europea su apoyo en el marco del proyecto DECAB (NÚMERO de subvención GV/2021/149) y del proyecto H2020, SMEmPower (GA 847132).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Measurement of power effects caused by the deterioration of the neutral conductor in three-phase distribution networks

  • Peñalvo-López, Elisa|||0000-0002-3143-822X
  • Leon-Vinet, Amparo|||0000-0003-3773-8116
  • León-Martínez, Vicente|||0000-0002-1906-371X
  • Montañana-Romeu, Joaquín|||0000-0003-3331-9205
  • Valencia-Salazar, Iván|||0000-0002-5223-4218
[EN] The expressions of the powers that measure the effects of the energies manifested by the deterioration of the neutral conductor in low-voltage distribution networks are developed in this paper with the name of neutral-displacement powers. The expressions of these powers have been obtained by applying the Principle of Energy Conservation to the entire three-phase system and the use of Buchholz's apparent source and load powers. Contrary to the traditional apparent powers of the neutral conductor, these new powers are not affected by the neutral currents and, therefore, their expressions can be applied to analyze the effects of the neutral conductor even though this conductor has been accidentally broken or disconnected. In the application example, based on the three-phase distribution network of a real industrial estate, it has been verified that the neutral-displacement powers reach a maximum value when the neutral conductor has been broken, while the traditional apparent powers of the neutral conductor are worth zero under those conditions. This result confirms that the neutral-displacement powers are more adequate quantities than the traditional ones to measure the impact that the deterioration and disconnection of the neutral conductor can cause in three-phase distribution networks., The work described in this paper has been sponsored and developed under the H2020 SMEmPower Projects (grant number 847132) of the European Commission and GV/2021/149, granted by the Generalitat Valenciana. Likewise, we would like to thank VINALESA DISTRIBUCIÓN DE ENERGÍA, S.L.U., for having made their distribution networks available to us to carry out the practical experiences.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Passive Reactive Power Compensators for Improving the Sustainability of Three-Phase Four-Wire Sinusoidal Systems Supplied by Unbalanced Voltages

  • Peñalvo-López, Elisa|||0000-0002-3143-822X
  • León-Martínez, Vicente|||0000-0002-1906-371X
  • Montañana-Romeu, Joaquín|||0000-0003-3331-9205
  • Cárcel-Carrasco, Javier|||0000-0003-2776-533X
[EN] Compensation of reactive power is necessary in power systems due to economical, energetic, and environmental reasons. Reactive power increases energy power losses and carbon dioxide emissions in distribution lines and power transformers. However, capacitor banks used in most industrial applications do not significantly reduce energy losses in lines and transformers when supply voltages and loads are unbalanced and therefore do not fully improve the sustainability of distribution networks. This fact is explained in this paper using positive-, negative-, and zero-sequence reactive power components in three-phase, four-wire sinusoidal power systems supplied with unbalanced voltages. Likewise, several devices have also been developed for the compensation of the total reactive power and, specifically, for each of its components in these power systems. Comparing the effectiveness of these reactive compensators and other well-known passive compensators as capacitor banks on the sustainability improvement of the electrical installation of an actual industry, reductions between 20% and 100% in energy losses and carbon dioxide emissions, caused by circulation of reactive currents in transformer and lines, can be expected depending on the type of compensator used., This research was funded by GENERALITAT VALENCIANA, grant number GV/2021/149 and the H2020 project, SMEmPower, grant number 847132. The APC was funded by GENERALITAT VALENCIANA
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Decarbonization of Distribution Transformers Based on Current Reduction: Economic and Environmental Impacts

  • León-Martínez, Vicente|||0000-0002-1906-371X
  • Andrada-Monrós, Clara|||0000-0001-6344-6649
  • Peñalvo-López, Elisa|||0000-0002-3143-822X
  • Molina-Cañamero, Laura
  • Cano-Martinez, Jorge
[EN] Well-known industrial practice efficiency improvement techniques, such as reactive compensation, load balancing, and harmonic filtering, are used in this paper to reduce energy losses in distribution transformers, and therefore, to decrease carbon dioxide emissions and economic costs in the operation of these transformers. Load balancing is carried out by monitoring the values of the angles of the active and reactive components of the vector unbalanced power. Likewise, the application of Order 3/2020 of the Spanish National Markets and Competition Commission is described, in detail, for the calculation of the economic costs derived from the transformer energy losses caused by the load currents and the penalties due to transformer energy deliveries with capacitive power factors. Finally, all these improvement techniques are applied to determine savings in carbon dioxide emissions and costs on the electricity bill of an actual 1000 kVA distribution transformer that supplies a commercial and night-entertainment area. The results of this application case reveal that cost reductions due to energy loss savings are modest, but the reduction in carbon dioxide emissions and the savings in penalties for capacitive reactive supplies are significant., This research was funded by Generalitat Valenciana (grant number GV/2021/149) and the H2020 project SMEmPower (grant number 847132). The APC was funded by Generalitat Valenciana.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Relationship between Buchholz&apos, s Apparent Power and Instantaneous Power in Three-Phase Systems

  • León-Martínez, Vicente|||0000-0002-1906-371X
  • Montañana-Romeu, Joaquín|||0000-0003-3331-9205
  • Peñalvo-López, Elisa|||0000-0002-3143-822X
  • Valencia-Salazar, Iván|||0000-0002-5223-4218
[EN] Similarly to how Steinmetz developed his theory of alternating current in single-phase sinusoidal systems, a few formal relationships between expressions of the instantaneous and Buchholz's apparent power in three-phase systems were identified in this paper. Based on these relationships, a methodology to express Buchholz's apparent power and its components in any three-phase, wye-configured system-sinusoidal or non-sinusoidal, balanced or unbalanced-through instantaneous power expressions was established. The application of the proposed method to the entire system allowed the determination of a novel quantity referred to as neutral-displacement power, which measured the impacts of the phenomena caused by the neutral path operation on the values of the source and load apparent power. These impacts were analyzed using a real-world urban installation with a neutral conductor deterioration simulation via an Excel platform as an application example., This research was funded by the European Commission, grant number 847132. The APC was funded by the European Commission, grant number 847132. We gratefully thank Eléctrica de Vinalesa, S.L.U., for allowing us to take measurements using their electrical networks, and MDPI (www.mdpi.com/authors/english) for their English language editing. The authors deeply thank the European Commission for their support and funding provision.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Procedure for Improving the Energy, Environmental and Economic Sustainability of Transformation Houses

  • León-Martínez, Vicente|||0000-0002-1906-371X
  • Peñalvo-López, Elisa|||0000-0002-3143-822X
  • Andrada-Monrós, Clara|||0000-0001-6344-6649
  • Leon-Vinet, Amparo|||0000-0003-3773-8116
  • Cano-Martinez, Jorge
  • Molina-Cañamero, Laura
[EN] A procedure for improving the energy, economic and environmental sustainability of the transformation houses in low-voltage distribution networks is described in this paper. This procedure is based on the reduction of the transformer consumption, copper and core losses. Likewise, the procedure distinguishes between transformation houses with old and new transformers. The reduction of core losses, replacing transformers with others of lower power or that are more efficient, achieves significant improvements in energy and environmental aspects. The reduction of copper losses, and applying reactive compensation techniques, such as harmonic filtering and load balancing, applied in old and new transformation houses, have a greater impact on cost savings, especially when there are capacitive consumptions, as the Circular 3/2020 of the National Markets and Competition Commission of Spain determines. The procedure has been applied to an industrial transformation house, which has an old 1600 kVA transformer, resulting in significant economic savings and CO2 reductions of more than 60%, after replacing the current transformer with a more efficient one., This research was funded by Generalitat Valenciana (grant number GV/2021/149) and the H2020 project SMEmPower (grant number 847132). The APC was funded by Generalitat Valenciana.