Experimental investigation of Ethane and Propane injection under sub- and super-critical conditions
[EN] Studying a fluid flow under high-pressure conditions through reliable experiments is still nowadays a challenge.
When the chamber pressure exceeds the critical pressure of working fluids the supercritical state of matter is
reached and the distinction between gas and liquid becomes blurred. For such special conditions, experimental
data are scarce and need to be consolidated. Indeed, the modification of the local refractive index induced by density
gradient needs to be analyzed with appropriate image-based technique.
In the present study, the REFINE test bench (Real-gas Effect on Fluid Injection: a Numerical and Experimental
study) has been designed at CORIA Lab to study the non-reactive injection of Ethane and Propane into Nitrogen
under sub- and supercritical conditions. The ambient gas pressure can be raised up to 6 MPa and warmed up
to 573 K to scan sub- and trans-critical injections. The chamber is equipped with two perpendicular optical axes
allowing simultaneously different optical diagnostics. Experimental data are collected from shadowgraph and diffused
backlight illumination techniques. Quantitative measurements of jet spreading angle and breakup length are
compared to results coming from literature exhibiting multiple flows topologies., This work was funded by the ANR (Agence Nationale de la Recherche) research project REFINE (Real-gas Effects on Fluid Injection: a Numerical and Experimental study), Grant No. ANR-13-BS09-0007.