Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Microalgae-bacteria consortia in high-rate ponds for treating urban wastewater: Elucidating the key state indicators under dynamic conditions

  • Robles Martínez, Ángel
  • Capson-Tojo, Gabriel
  • Gales, Amandine
  • Ruano, María Victoria
  • Sialve, Bruno
  • FERRER, J.
  • Steyer, Jean-Philippe
[EN] On-line performance indicators of a microalgae-bacteria consortium were screened out from different variables based on pH and dissolved oxygen on-line measurements via multivariate projection analysis, aiming at finding on-line key state indicators to easily monitor the process. To fulfil this objective, a pilot-scale high-rate pond for urban wastewater treatment was evaluated under highly variable conditions, i.e. during the start-up period. The system was started-up without seed of either bacterial or microalgal biomass. It took around 19 days to fully develop a microalgal community assimilating nutrients significantly. Slight increases in the biomass productivities in days 26-30 suggest that the minimum time for establishing a performant bacteria-microalgae consortium could be of around one month for non-inoculated systems. At this point, the process was fully functional, meeting the European discharge limits for protected areas. The results of the statistical analyses show that both the pH and the dissolved oxygen concentration represent accurately the biochemical processes taking place under the start-up of the process. Both pH and dissolved oxygen represented accurately also the performance of the high-rate algal pond, being affordable, easily-implemented, options for monitoring, control and optimization of industrial-scale processes., The authors acknowledge the financial support of the French National Research Agency (ANR) for the "Phycover" project (project ANR-14-CE04-0011), the Spanish Ministry of Economy and Competitiveness (MINECO, Projects CTM 2014-54980-C2-1-R and CTM 2014-54980-C2-2-R) jointly with the European Regional Development Fund (ERDF), and the European Climate KIC association for the "MAB 2.0" project (APIN0057_2015-3.6-230_P066-05). Angel Robles would also like to acknowledge the financial aid received from Generalitat Valenciana via a VALi d post-doctoral grant (APOSTD/2014/049). Gabriel Capson-Tojo is grateful to the Xunta de Galicia for his postdoctoral fellowship (ED481B-2018/017).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Instrumentation and control of anaerobic digestion processes: a review and some research challenges

  • Jimenez, Julie
  • Latrille, Eric
  • Harmand, J
  • Robles Martínez, Ángel
  • FERRER, J.
  • Gaida, D
  • Wolf, C.
  • Mairet, F.
  • Bernard, O.
  • Alcaraz-Gonzalez, V.
  • Mendez-Acosta, H.
  • Zitomer, D.
  • Totzke, D.
  • Spanjers, H.
  • Jacobi, F.
  • Guwy, A.
  • Dinsdale, R.
  • Premier, G.
  • Mazhegrane, S.
  • Ruiz-Filippi, G.
  • Seco, A.
  • Ribeiro, T.
  • Pauss, A.
  • Steyer, J.P.
[EN] To enhance energy production from methane or resource recovery from digestate, anaerobic digestion processes require advanced instrumentation and control tools. Over the years, research on these topics has evolved and followed the main fields of application of anaerobic digestion processes: from municipal sewage sludge to liquid mainly industrial then municipal organic fraction of solid waste and agricultural residues. Time constants of the processes have also changed with respect to the treated waste from minutes or hours to weeks or months. Since fast closed loop control is needed for short time constant processes, human operator is now included in the loop when taking decisions to optimize anaerobic digestion plants dealing with complex solid waste over a long retention time. Control objectives have also moved from the regulation of key variables measured online to the prediction of overall process perfor- mance based on global off-line measurements to optimize the feeding of the processes. Additionally, the need for more accurate prediction of methane production and organic matter biodegradation has impacted the complexity of instrumentation and should include a more detailed characterization of the waste (e.g., biochemical fractions like proteins, lipids and carbohydrates)andtheirbioaccessibility andbiodegradability characteristics. However, even if in the literature several methodologies have been developed to determine biodegradability based on organic matter characterization, only a few papers deal with bioaccessibility assessment. In this review, we emphasize the high potential of some promising techniques, such as spectral analysis, and we discuss issues that could appear in the near future concerning control of AD processes., The authors acknowledge the financial support of INRA (the French National Institute for Agricultural Research), the French National Research Agency (ANR) for the "Phycover" project (project ANR-14-CE04-0011) and ADEME for Inter-laboratory assay financial support.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Performance of a membrane-coupled high-rate algal pond for urban wastewater treatment at demonstration scale

  • Robles Martínez, Ángel
  • Capson-Tojo, Gabriel
  • Gales, Amandine
  • Viruela, Alexandre
  • Sialve, Bruno
  • Seco, Aurora
  • Steyer, Jean-Philippe
  • FERRER, J.
[EN] The objective of this study was to evaluate the performance of an outdoor membrane-coupled high-rate algal pond equipped with industrial-scale membranes for treating urban wastewater. Decoupling biomass retention time (BRT) and hydraulic retention time (HRT) by membrane filtration resulted in improved process efficiencies, with higher biomass productivities and nutrient removal rates when operating at low HRTs. At 6 days of BRT, biomass productivity increased from 30 to 66 and to 95 g.m(-3).d(-1) when operating at HRTs of 6, 4 and 2.5 days, respectively. The corresponding nitrogen removal rates were 4, 8 and 11 g N.m(-3).d(-1) and the phosphorous removal rates were 0.5, 1.3 and 1.6 g P.m(-3).d(-1). The system was operated keeping moderate specific air demands (0.25 m(3).m(-2).h(-1)), resulting in reasonable operating and maintenance costs ((sic)0.04 per m(3)) and energy requirements (0.29 kWh per m(3)). The produced water was free of pathogens and could be directly used for reusing purposes., The authors thank the financial support of the French National Research Agency (ANR) for the "Phycover" project (project ANR-14-CE04-0011), the Spanish Ministry of Economy and Competitiveness jointly with the European Regional Development Fund (project CTM2011-28595-C02-01/02), and the European Climate KIC association for the "MAB 2.0" project (APIN0057_2015-3.6-230_P066-05). Angel Robles is also grateful to the Generalitat Valenciana for the financial aid received via a VALi+d post-doctoral grant (APOSTD/2014/049). Gabriel Capson-Tojo would like to acknowledge the Xunta de Galicia for his postdoctoral fellowship (ED481B-2018/017).