Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 7
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Overview of DETESTS-Dis at IberLEF 2024:DETEction and classification of racial STereotypes inSpanish - Learning with Disagreement

  • Wolfgang S. Schmeisser-Nieto
  • Pastells, Pol
  • Frenda, Simona
  • Alejandro Ariza-Casabona
  • Farrús, Mireia
  • Taulé, Mariona
  • Rosso, Paolo|||0000-0002-8922-1242
[ES] Este artículo presenta un resumen de la tarea DETESTS como parte del workshop IberLEF 2024, dentro del congreso SEPLN 2024. Propusimos dos subtareas jerárquicas: En la subtarea 1, los participantes tuvieron que determinar la presencia de estereotipos raciales en oraciones. En la subtarea 2, de las oraciones etiquetadas con estereotipo, los participantes tuvieron que decidir si este era implícito. El dataset DETESTS-Dis contiene 12.111 oraciones de comentarios y tuits respondiendo a artículos de periódicos y bulos raciales sobre inmigración en español. 15 equipos se registraron para participar, de los cuales 6 enviaron predicciones de sistemas y 3 de ellos enviaron artículos. En este artículo presentamos información sobre los datasets de entrenamiento y de prueba, los sistemas utilizados por los participantes, las métricas de evaluación y sus resultados., [EN] This paper presents an overview of the DETESTS-Dis shared task aspart of the IberLEF 2024 Workshop on Iberian Languages Evaluation Forum, withinthe framework of the SEPLN 2024 conference. We proposed two hierarchical sub-tasks: In subtask 1, participants had to determine the presence of stereotypes in thetexts. For subtask 2, participants had to decide which texts labeled with stereotypeswere implicit stereotypes. The DETESTS-Dis dataset contains 12,111 comment sen-tences and tweets in response to newspaper articles and verified racial hoaxes involv-ing immigration in Spanish. 15 teams signed up to participate, 6 of which sent runs,and 3 of them sent their working notes. In this paper, we provide information aboutthe training and test datasets, the systems used by the participants, the evaluationmetrics of the systems and their results, This work was supported by the interna-tional project STERHEOTYPES: STudyingEuropean Racial Hoaxes and sterEOTYPESfunded by the Compagnia di San Paolo andVolksWagen Stiftung under the Challengesfor Europe call (CUP: B99C20000640007) ;the SGR CLiC project (2021 SGR 00313) funded by the Generalitat de Catalunya,and the FairTransNLP-Language project (PID2021-124361OB-C33) funded by MI-CIU/AEI/10.13039/501100011033/and byFEDER, UE.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Evaluation of patient visual comfort and repeatability of refractive values in non-presbyopic healthy eyes

  • Segura, F.
  • Sanchez-Cano, A.
  • Lopez de la Fuente, C
  • Fuentes-Broto, L.
  • Pinilla, I.
•AIM: To evaluate the intra-operator repeatability in healthy subjects using the WAM-5500 auto-kerato/refractometer and the iTrace aberrometer, to compare the refractive values and the subjective refraction obtained with both devices and to determine which of these three spherocylindrical corrections allows the subject to achieve the best visual comfort. •METHODS: Forty-two non-presbyopic healthy eyes of 42 subjects were enrolled in this prospective study. Refractive values were compared, evaluating the repeatability, the relationship between the methods and the best visual comfort obtained. •RESULTS: Sphere, cylinder and axis results showed good intraclass correlation coefficients (ICC); the highest ICC was obtained using the spherical refraction with the autorefractometer and the aberrometer, achieving levels of 0.999 and 0.998, respectively. The power vector (PV) was calculated for each refraction method, and the results indicated that there were no statistically significant differences between them (P>0.05). Direct comparison of PV measurements using the three methods showed that aberrometer refraction gave the highest values, followed by the subjective values; the autorefractometer gave the lowest values. The subjective method correction was most frequently chosen as the first selection. Equal values were found for the autorefractometer and the aberrometer as the second selection. •CONCLUSION: The iTrace aberrometer and the WAM-5500 auto-kerato/refractometer showed high levels of repeatability in healthy eyes. Refractive corrections with the aberrometer, the autorefractometer and subjective methods presented similar results, but spherocylindrical subjective correction was the most frequently selected option. These technologies can be used as complements in refractive evaluation, but they should not replace subjective refraction.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Assessment of Visual and Chromatic Functions in a Rodent Model of Retinal Degeneration

  • Segura, Francisco
  • Sanchez-Cano, Ana
  • Jarabo Lallana, Sebastián
  • Lopez de la Fuente, Carmen
  • Cuenca, Nicolas
  • Villegas-Perez, Maria P
  • Pinilla, Isabel
Purpose: We evaluated the photoreceptor response of pigmented P23H and normal pigmented Long Evans (LE) rats over time using functional tests in variable lighting conditions. Methods: Pigmented P23H rats were studied by optomotor testing and electroretinogram (ERG) recordings at P30, P150, and P240. Pigmented LE rats were used as a normal wild-type control. Stimuli were modified with colored filters. Neutral density filters were used to reduce luminance. Results: Age-related decreases in visual acuity (VA) and contrast sensitivity (CS) were observed in P23H rats. Good correlations in measurements without filter and with green filter were observed between LE and P23H P30 rat values. Differences between groups were smaller with red and purple filters. A strong relationship with luminance was observed in LE rats (VA and CS) and with P23H P30 rats (CS). A decline in the ERG responses of P23H rats was consistent with the gradual loss of photoreceptors. Differences in a- and b-wave amplitudes with different colored filters were negligible with the exception of the red filter, which resulted in smaller responses. Conclusions: Visual function parameters decreased with age in pigmented P23H rats. Irrespective of luminance, color filter, and retinal degeneration, minimum thresholds of VA and CS were found. Smaller differences than expected were found using color filters. Responses to functional tests at long wavelengths were observed, where there is very low photoreceptor spectral sensitivity. The use of filters with functional testing could minimize light-induced retinal damage in rats.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Changes in frequency-doubling perimetry in patients with type i diabetes prior to retinopathy

  • Pinilla, I.
  • Ferreras, A.
  • Idoipe, M.
  • Sanchez-Cano, A.
  • Perez-Garcia, D.
  • Herrera, L.X.
  • Pinilla, M.J.
  • Abecia, E.
Purpose. To evaluate the ability of frequency-doubling technology (FDT) perimetry in detecting visual field defects in young adults with type I diabetes prior to retinopathy or with minor retinovascular changes. Methods. This comparative cross-sectional study included 30 healthy subjects and 73 age-matched patients with type I diabetes mellitus. All subjects underwent a full ocular examination including an FDT with the threshold C-20-5 strategy. Only one eye per subject was randomly included in the statistical analysis. FDT results and time to perform the test were compared between the groups. Results. The mean age was 27.1 years in the control group and 26.6 years in the diabetic group ( ). The mean period from the onset of diabetes was years, while minimal retinovascular changes were observed in 18 eyes. Mean deviation of FDT did not differ between the groups. Although global indices of FDT were within normal limits, pattern standard deviation of FDT was higher in the diabetic group ( ). The area under the receiver operating characteristic curve was 0.647 for pattern standard deviation of FDT (standard error = 0.052; ). Conclusion. FDT can detect retinal dysfunctions in diabetic patients prior to the onset of significant vascular complications.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Long time remodeling during retinal degeneration evaluated by optical coherence tomography, immunocytochemistry and fundus autofluorescence

  • Pinilla, Isabel
  • Fernández Sánchez, Laura
  • Segura, Francisco Javier
  • Sánchez Cano, Ana Isabel
  • Tamarit, José María
  • Fuentes Broto, Lorena
  • Eells, Jt
  • Lax, Pedro
  • Cuenca, Nicolás
Purpose: To characterize the relationship between fundus autofluorescence (FAF), Optical Coherence Tomography (OCT) and immuno histo chemistry (IHC) over the course of chronic retinal degeneration in the P23H rat. Methods: Homozygous albino P23H rats, SpragueeDawley (SD) rats as controls and pigmented Long Evans (LE) rats were used. A Spectralis HRA OCT system was used for scanning laser ophthalmoscopy (SLO) imaging OCT and angiography. To determine FAF, fluorescence was excited using diode laser at 488 nm. A fast retina map OCT was performed using the optic nerve as a landmark. IHC was performed to correlate with the findings of OCT and FAF changes. Results: During the course of retinal degeneration, the FAF pattern evolved from some spotting at 2 months old to a mosaic of hyper fluorescent dots in rats 6 months and older. Retinal thicknesses progressively diminished over the course of the disease. At later stages of degeneration, OCT documented changes in the retinal layers, however, IHC better identified the cell loss and remodeling changes. Angiography revealed attenuation of the retinal vascular plexus with time. Conclusion: We provide for the first time a detailed long-term analysis of the course of retinal degeneration in P23H rats using a combination of SLO and OCT imaging, angiography, FAF and IHC. Although, the application of noninvasive methods enables longitudinal studies and will decrease thenumber of animals needed for a study, IHC is still an essential tool to identify retinal changes at the cellular level.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Spectral attenuation of brain and retina tissues in the near-infrared range measured using a fiber-based supercontinuum device

  • Saldaña-Díaz, José Eduardo
  • Jarabo, Sebastián
  • Salgado-Remacha, Francisco Javier
  • Perdices, Lorena
  • Pinilla, Isabel
  • Sanchez-Cano, Ana
A novel setup for the efficient constant optical measurements of biological tissues in the near infrared is presented. The system combines the use of a fiber-based supercontinuum source with a simple optics fiber collimator. This configuration allows a wide spectral range of measurement and, at the same time, can efficiently filter the straightforward transmitted light while avoiding scattered light. As a performance example, the optical characterization of rat brain and retina tissues are shown. The attenuation coefficient for both tissues in the near infrared region is also obtained. This technique could be applied in clinical research as a noninvasive method with several potential practical applications.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Development of optokinetic tracking software for objective evaluation of visual function in rodents

  • Segura, Francisco
  • Arines, Justo
  • Sánchez-Cano, Ana
  • Perdices, Lorena
  • Orduna-Hospital, Elvira
  • Fuentes-Broto, Lorena
  • Pinilla, Isabel
The aim of this study was to develop software that performs the optokinetic tracking assessment without the involvement of experimenters to increase the objectivity of the test. To check the effectiveness of the software, several videos were analyzed and the results were compared to those produced by two experimenters. Videos consisted of visual acuity and contrast sensitivity tests on normal animals and pigmented P23H rats (animal model of retinitis pigmentosa). Our software showed a reasonably high success rate: in approximately 78% of the cases, both the software program and the experimenters were in agreement, including the direction of rotation. The software detected 7% false positive cases, 10% false negative cases, and it was wrong in 5% of the cases. Decrease in visual function with age in pigmented P23H rats was observed from the first time interval, although minimum thresholds were found in visual parameters at advanced ages. We developed simple software based on current functions included in the Matlab image processing toolbox that was able to recognize, with a reasonably high percentage of success, the subtle head movements of the rodent produced when visual perception of the optokinetic optotype occurs.