Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Simulation and design recommendations of eccentrically loaded slender concrete-filled tubular columns

  • Portoles Flaj, José Manuel
  • Romero, Manuel L.
  • Filippou, Filip C.
  • Bonet Senach, José Luís|||0000-0002-6687-5307
This paper proposes an efficient numerical model for the simulation of the behavior of slender circular concrete-filled tubular columns subjected to eccentric axial load with single curvature, for the cases of both normal and high strength concrete. The paper focuses on the study of the influence that the variables affecting beam–column behavior (length and relative slenderness) and the variables affecting section behavior (diameter/thickness ratio, mechanical capacity of steel) have on the overall buckling of this type of column. An extended parametric study is carried out to propose design recommendations, primarily to establish the importance of the use of high strength concrete compared with that of normal strength concrete. The results show that for slender elements the optimum design is reached when the mechanical capacity of the steel is slightly lower than that of the concrete contribution., The authors wish to express their sincere gratitude to the Spanish "Ministerio de Educacion" for help provided with project BIA2005_255, and to the Spanish "Ministerio de Ciencia e Innovacion" with project BIA2009-09411, to the European Community for FEDER funds, and to the Fundacio Caixa Castello-Bancaixa.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Influence of Slenderness on High-Strength Rectangular Concrete-Filled Tubular Columns with Axial Load and Nonconstant Bending Moment

  • Hernández Figueirido, David
  • Romero, Manuel L.|||0000-0001-5247-4767
  • Bonet Senach, José Luís|||0000-0002-6687-5307
  • Montalva-Subirats, Jose-Miguel|||0000-0002-1855-9596
Forty-nine experimental tests were conducted on rectangular and square tubular columns filled with high-strength concrete (f'(c) 590 MPa) subjected to axial load and a nonconstant bending moment distribution. The test parameters were the length (2, 3, and 4 m), the cross-section aspect ratio (square or rectangular), the wall thickness (4 or 5 mm), and the ratio of the top and bottom first-order eccentricities r = e(top)/e(bottom) (1, 0.5, 0, and -0.5). The effect of slenderness combined with the influence of variable curvature is compared with the design loads from AISC 360-10 and Eurocode 4. The results show that, for the slender elements of this experimental campaign, both codes present a similar error close to 4%. The small error margin indicates that both standards are applicable to high-strength concrete, although the concrete tested is outside the upper bond of Eurocode 4 and AISC's specifications. However, there are particular cases that present excessive unsafe errors. These errors correspond to the cases where the second-order effects are more important and are attributable to an overestimation of the flexural stiffness E x I, which indicates that it needs correction. DOI: 10.1061/(ASCE)ST.1943-541X.0000590. (C) 2012 American Society of Civil Engineers., The authors express their gratitude to the Spanish Ministry of Science and Innovation for help provided through Grant No. BIA2009_9411, to the Spanish Ministry of Education through Grant No. BIA2005-255, and the European Union for FEDER Funds.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Experimental study of high strength concrete-filled circular tubular columns under eccentric loading

  • Portoles, J.M.
  • Filippou, F.C.
  • Romero, Manuel L.|||0000-0001-5247-4767
  • Bonet Senach, José Luís|||0000-0002-6687-5307
The paper describes 37 tests conducted on slender circular tubular columns filled with normal and high strength concrete subjected to eccentric axial load. The test parameters were the nominal strength of concrete (30, 70 and 90 MPa), the diameter to thickness ratio Dt, the eccentricity ratio eD and the column slenderness (LD). The experimental ultimate load of each test was compared with the design loads from Eurocode 4, which limits the strength of concrete up to 50 MPa. The aim of the paper is to establish the advisability of the use of high strength concretes as opposed to that of normal strength concretes by comparing three performance indices: concrete contribution ratio, strength index and ductility index. The results show for the limited cases analyzed that the use of high strength concrete for slender composite columns is interesting since this achieves ductile behavior despite the increase in load-carrying capacity is not greatly enhanced. © 2010 Elsevier Ltd. All rights reserved., The authors wish to express their sincere gratitude to the Spanish Ministry of Education for help provided through project BIA2005_255 and BIA 2009_09411, to the European Community for FEDER funds, and to the Fundacio Caixa Castello-Bancaixa.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Inelastic Effective Length Factor of Nonsway Reinforced Concrete Columns

  • Bendito, A.
  • Romero, Manuel L.|||0000-0001-5247-4767
  • Bonet Senach, José Luís|||0000-0002-6687-5307
  • Miguel Sosa, Pedro|||0000-0001-5395-8149
  • Fernández Prada, Miguel Ángel|||0000-0001-5527-7793
[EN] This paper proposes a new equation for the effective length factor k-factor for reinforced concrete columns in braced frames. The new formula is valid both for normal and high-strength concrete. The equation was obtained from a sensitivity analysis performed on a two-dimensional nonlinear finite-element numerical model that takes into account the inelastic behavior of the concrete columns cracking, yielding, and second order effects. The numerical model was calibrated with 44 experimental tests performed by the writers¿ research group. A comparative study was carried out between the numerical model and different national design codes, displaying important differences with respect to all of them: the ACI code from 37 to 3%, the Spanish code EHE from 26 to 9.26%, and the Eurocode 2 from 14 to 14%. It was decided to propose two additional simplified equations: one for checking and the second for design., The authors wish to express their sincere gratitude to the Spanish Ministerio de Fomento for help provided through project 13-12-2001 and Ministerio de Educación through BIA2005-255.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Ultimate capacity of rectangular concrete-filled steel tubular columns under unequal load eccentricities

  • Hernández Figueirido, David
  • Romero, Manuel L.|||0000-0001-5247-4767
  • Bonet Senach, José Luís|||0000-0002-6687-5307
  • Montalva-Subirats, Jose-Miguel|||0000-0002-1855-9596
The paper describes 36 experimental tests conducted on rectangular and square tubular columns filled with normal and high strength concrete and subjected to a non-constant bending moment distribution with respect to the weak axis. The test parameters were the nominal strength of concrete (30 and 90 MPa), the cross-section aspect ratio (square or rectangular), the thickness (4 or 5 mm) and the ratio of the top and bottom first order eccentricities e top/e bottom (1, 0.5, 0 and - 0.5). The ultimate load of each test was compared with the design loads from Eurocode 4, presenting unsafe results inside a 10% safety margin. The tests show that the use of high strength concrete is more useful for the cases of non-constant bending moment, whereas if the aim is to obtain a more ductile behavior the use of concrete-filled columns is more appealing in the cases of normal strength concrete with non-constant bending moments because, although they resist less axial force than the members with HSC, they obtain a softened post-peak behavior. © 2011 Elsevier Ltd., The authors wish to express their sincere gratitude to the Spanish Ministry of Education for the help provided through projects BIA2005_255 and BIA2009_9411, and to the European Community for FEDER funds.