Pasar al contenido principal

EVALUACION DE LOS EFECTOS DEL DETERIORO, REPARACION Y REFUERZO EN ESTRUCTURAS. MODELO TEORICO Y VERIFICACION EXPERIMENTAL

BIA2009-11764

•
Nombre agencia financiadora Ministerio de Ciencia e Innovación
Acrónimo agencia financiadora MICINN
Programa Programa Nacional de Proyectos de Investigación Fundamental
Subprograma Subprograma de Proyectos de Investigación Fundamental no Orientada
Convocatoria Proyectos I+D
Año convocatoria 2009
Plan Estatal 2008-2011 Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica
Unidad de gestión Subdirección General de Proyectos de Investigación
Centro beneficiario UNIVERSITAT POLITECNICA DE CATALUNYA
Identificador persistente http://dx.doi.org/10.13039/501100004837

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

RUC. Repositorio da Universidade da Coruña
Publicación Artículo científico (JournalArticle)

Ultimate Capacity of Corroded Statically Indeterminate Reinforced Concrete Members

  • Fernández, Ignasi
  • Herrador, Manuel
  • Marí, Antonio
  • Bairan, JM
[Abstract:] The corrosion of steel reinforcement is commonly believed to be the primary cause of structural deterioration of reinforced concrete (RC) structures; as a result of this deterioration, a RC structure can incur a considerable reduction in structural serviceability and safety. Because of their inherent redundancy, statically indeterminate structures develop resistant mechanisms that can potentially assist in delaying the collapse of severely damaged RC structures. In order to experimentally demonstrate these resistant mechanisms, four groups of three two-span continuous RC beam members each were deteriorated using induced corrosion methods and tested to failure under monotonic loads. For control, one group of three RC beams was left uncorroded and similarly load tested. All the RC beam specimens subjected to corrosion demonstrated a significant reduction (a maximum reduction of 55% as compared to the uncorroded control group) of their ultimate capacity. The presence of corrosion induced a transition from flexural failure to anchorage failure in some specimens; despite the induced damage some redistributed structural capacity was observed. Modelling of deterioration effects by the inclusion of different aspects of corrosion was also conducted. Three-dimensional (3D) Finite-Element Method (FEM) models were developed to assess the variation in the mechanical properties of the corroded steel and the reduction in the bond interaction between concrete and steel due to the corrosion of the steel reinforcement. In general, the current 3D FEM models demonstrated a good agreement with the experimental data; however, 3D FEM models that exhibit greater sophistication are necessary to better describe the failure mode of some RC beam specimens when they are associated with local effects., The authors wish to acknowledge the financial support of the European Regional Development Fund (ERDF) and The Ministry of Economy and Competitiveness of the Government of Spain (MINECO) for providing funds for projects BIA2009-11764, BIA2015-64672-C4-1-R, BIA2015-64672-C4-2-R. The financial support of Infrastructures de Catalunya (ICAT) was also highly appreciated.
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Assessment of the efficiency of strengthening solutions in concrete structures by means of non-linear step by step analysis models, Evaluación de la eficiencia de soluciones de refuerzo en estructuras de hormigón mediante análisis no lineal evolutivo

  • Marí Bernat, Antonio Ricardo|||0000-0002-0994-0715
  • Bairán García, Jesús Miguel|||0000-0003-2831-1479
  • Oller Ibars, Eva|||0000-0002-0845-3587
When designing a structural strengthening solution, the influence of the previous state of the structure on the capacity of the strengthened structure must be evaluated. In addition, strengthening interventions may involve operations such as partial unloading of the structure, placement and removal of temporary shores, application of loads or pre-deformations, restoring of damaged reinforcement or spalled con-crete or constraining of lateral strains. Therefore, changes in the cross-section geometry and reinforcement, longitudinal scheme, support conditions, loads and state of stresses and strains, may take place. Furthermore, occurrence of phenomena producing a premature failure or a change in the failure mode, should be avoided. In order to account for such a large variety of causes and phenomena affecting the structural response, a nonlinear and time-dependent analysis model of 3D reinforced and prestressed concrete frames, capable of capturing different failure modes and taking into account the structural history, is described. The model has been verified with tests on strengthened structures available in the literature and has been applied to an actually remodeled structure, comparing the advantages and disadvantages of two different strengthening proposals, showing its capabilities to assess the efficiency of structural strengthening systems., This paper is dedicated to the memory of an extraordinary engineer and human being, Luis Ortega Basagoiti, who was an example and reference for structural engineers and researchers along his professional career. The works described in this paper have been developed in the framework of the following research projects funded by the Spanish Science and Technology Ministries and by the European Funds for Regional Development, ADRESS (BIA2009-11764), REHABCAR (IPT-370000-2010-029), HORVITAL (BIA2015-64672-C4-1-R) and STRADURAVIUS (RTI2018-097314-B-C21)., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Ultimate capacity of corroded statically indeterminate reinforced concrete members

  • Fernández Pérez, Ignacio
  • Herrador Barrios, Manuel F.
  • Marí Bernat, Antonio Ricardo|||0000-0002-0994-0715
  • Bairán García, Jesús Miguel|||0000-0003-2831-1479
The corrosion of steel reinforcement is commonly believed to be the primary cause of structural deterioration of reinforced concrete (RC) structures; as a result of this deterioration, a RC structure can incur a considerable reduction in structural serviceability and safety. Because of their inherent redundancy, statically indeterminate structures develop resistant mechanisms that can potentially assist in delaying the collapse of severely damaged RC structures. In order to experimentally demonstrate these resistant mechanisms, four groups of three two-span continuous RC beam members each were deteriorated using induced corrosion methods and tested to failure under monotonic loads. For control, one group of three RC beams was left uncorroded and similarly load tested. All the RC beam specimens subjected to corrosion demonstrated a significant reduction (a maximum reduction of 55% as compared to the uncorroded control group) of their ultimate capacity. The presence of corrosion induced a transition from flexural failure to anchorage failure in some specimens; despite the induced damage some redistributed structural capacity was observed. Modelling of deterioration effects by the inclusion of different aspects of corrosion was also conducted. Three-dimensional (3D) Finite-Element Method (FEM) models were developed to assess the variation in the mechanical properties of the corroded steel and the reduction in the bond interaction between concrete and steel due to the corrosion of the steel reinforcement. In general, the current 3D FEM models demonstrated a good agreement with the experimental data; however, 3D FEM models that exhibit greater sophistication are necessary to better describe the failure mode of some RC beam specimens when they are associated with local effects., Peer Reviewed
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Ultimate capacity of corroded statically indeterminate reinforced concrete members

  • Fernández Pérez, Ignacio
  • Herrador Barrios, Manuel F.
  • Marí Bernat, Antonio Ricardo
  • Bairán García, Jesús Miguel
The corrosion of steel reinforcement is commonly believed to be the primary cause of structural deterioration of reinforced concrete (RC) structures; as a result of this deterioration, a RC structure can incur a considerable reduction in structural serviceability and safety. Because of their inherent redundancy, statically indeterminate structures develop resistant mechanisms that can potentially assist in delaying the collapse of severely damaged RC structures. In order to experimentally demonstrate these resistant mechanisms, four groups of three two-span continuous RC beam members each were deteriorated using induced corrosion methods and tested to failure under monotonic loads. For control, one group of three RC beams was left uncorroded and similarly load tested. All the RC beam specimens subjected to corrosion demonstrated a significant reduction (a maximum reduction of 55% as compared to the uncorroded control group) of their ultimate capacity. The presence of corrosion induced a transition from flexural failure to anchorage failure in some specimens; despite the induced damage some redistributed structural capacity was observed. Modelling of deterioration effects by the inclusion of different aspects of corrosion was also conducted. Three-dimensional (3D) Finite-Element Method (FEM) models were developed to assess the variation in the mechanical properties of the corroded steel and the reduction in the bond interaction between concrete and steel due to the corrosion of the steel reinforcement. In general, the current 3D FEM models demonstrated a good agreement with the experimental data; however, 3D FEM models that exhibit greater sophistication are necessary to better describe the failure mode of some RC beam specimens when they are associated with local effects., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Assessment of the efficiency of strengthening solutions in concrete structures by means of non-linear step by step analysis models, Evaluación de la eficiencia de soluciones de refuerzo en estructuras de hormigón mediante análisis no lineal evolutivo

  • Marí Bernat, Antonio Ricardo
  • Bairán García, Jesús Miguel
  • Oller Ibars, Eva
When designing a structural strengthening solution, the influence of the previous state of the structure on the capacity of the strengthened structure must be evaluated. In addition, strengthening interventions may involve operations such as partial unloading of the structure, placement and removal of temporary shores, application of loads or pre-deformations, restoring of damaged reinforcement or spalled con-crete or constraining of lateral strains. Therefore, changes in the cross-section geometry and reinforcement, longitudinal scheme, support conditions, loads and state of stresses and strains, may take place. Furthermore, occurrence of phenomena producing a premature failure or a change in the failure mode, should be avoided. In order to account for such a large variety of causes and phenomena affecting the structural response, a nonlinear and time-dependent analysis model of 3D reinforced and prestressed concrete frames, capable of capturing different failure modes and taking into account the structural history, is described. The model has been verified with tests on strengthened structures available in the literature and has been applied to an actually remodeled structure, comparing the advantages and disadvantages of two different strengthening proposals, showing its capabilities to assess the efficiency of structural strengthening systems., This paper is dedicated to the memory of an extraordinary engineer and human being, Luis Ortega Basagoiti, who was an example and reference for structural engineers and researchers along his professional career. The works described in this paper have been developed in the framework of the following research projects funded by the Spanish Science and Technology Ministries and by the European Funds for Regional Development, ADRESS (BIA2009-11764), REHABCAR (IPT-370000-2010-029), HORVITAL (BIA2015-64672-C4-1-R) and STRADURAVIUS (RTI2018-097314-B-C21)., Peer Reviewed, Postprint (published version)