Pasar al contenido principal

SENS4ALL. PRUEBAS RAPIDAS DE CARACTERISTICAS MEJORADAS PARA EL DIAGNOSTICO GLOBAL

BIO2016-75751-R

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos I+D+i Retos de Investigación
Año convocatoria 2016
Plan Estatal 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSIDAD AUTONOMA DE BARCELONA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Matrix effect in the isolation of breast cancer- derived nanovesicles by immunomagnetic separation and electrochemical immunosensing- A comparative study

  • Lima Moura, Silio|||0000-0001-8867-6029
  • Martí, Mercè|||0000-0002-1846-0043
  • Pividori, María Isabel|||0000-0002-5266-7873
Exosomes are cell-derived nanovesicles released into biological fluids, which are involved in cell-to-cell communication. The analysis of the content and the surface of the exosomes allow conclusions about the cells they are originating from and the underlying condition, pathology or disease. Therefore, the exosomes are currently considered good candidates as biomarkers to improve the current methods for clinical diagnosis, including cancer. However, due to their low concentration, conventional procedures for exosome detection including biosensing usually require relatively large sample volumes and involve preliminary purification and preconcentration steps by ultracentrifugation. In this paper, the immunomagnetic separation is presented as an alternative method for the specific isolation of exosomes in serum. To achieve that, a rational study of the surface proteins in exosomes, which can be recognized by magnetic particles, is presented. The characterization was performed in exosomes obtained from cell culture supernatants of MCF7, MDA- MB-231 and SKBR3 breast cancer cell lines, including TEM and nanoparticle tracking analysis (NTA). For the specific characterization by flow cytometry and confocal microscopy, different commercial antibodies against selected receptors were used, including the general tetraspanins CD9, CD63 and CD81, and cancer-related receptors (CD24, CD44, CD54, CD326 and CD340). The effect of the serum matrix on the immunomagnetic separation was then carefully evaluated by spiking the exosomes in depleted human serum. Based on this study, the exosomes were preconcentrated by immunomagnetic separation on antiCD81-modified magnetic particles in order to achieve further magnetic actuation on the surface of the electrode for the electrochemical readout. The performance of this approach is discussed and compared with classical characterization methods.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Electrochemical Genosensing of E. coli Based on Padlock Probes and Rolling Circle Amplification

  • Ben Aissa Soler, Alejandra|||0000-0002-0419-0572
  • Madaboosi, Narayanan
  • Nilsson, Mats
  • Pividori, María Isabel|||0000-0002-5266-7873
Isothermal amplification techniques are emerging nowadays for the rapid and accurate detection of pathogenic bacteria in low resource settings, where many infectious diseases are endemic, and the lack of reliable power supply, trained personnel and specialized facilities pose critical barriers for timely diagnosis. This work addresses the detection of E. coli based on DNA isothermal amplification performed on magnetic particles (MPs) followed by electrochemical genosensing on disposable electrodes by square-wave voltammetry. In this approach, the bacterial DNA is preconcentrated using a target-specific magnetic probe and then amplified on the MPs by rolling circle amplification (RCA). Two different electrochemical readout methods for the RCA amplicons are tested. The first one relied on the labelling of the magnetic RCA product with a digoxigenin probe followed by the incubation with antiDIG-HRP antibody as electrochemical reporter. In the second case, the direct detection with an HRP-probe was performed. This latter strategy showed an improved analytical performance, while simultaneously avoiding the use of thermocyclers or bulky bench top equipment.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Comparative Study of Gold and Carbon Nanoparticles in Nucleic Acid Lateral Flow Assay

  • Porras, Juan Carlos
  • Bernuz, Mireia|||0000-0002-2052-6902
  • Marfà, Jennifer|||0000-0001-5321-3841
  • Pallarès-Rusiñol, Arnau|||0000-0001-9990-148X
  • Martí, Mercè|||0000-0002-1846-0043
  • Pividori, María Isabel|||0000-0002-5266-7873
A lateral flow assay (LFA) is a paper-based, point-of-need test designed to detect a specific analyte in complex samples in low-resource settings. Although LFA has been successfully used in different applications, its use is still limited when high sensitivity is required, especially in the diagnosis of an early-stage condition. The limit of detection (LOD) is clearly related to the signal-generating system used to achieve the visual readout, in many cases involving nanoparticles coupled to a biomolecule, which, when combined, provides sensitivity and specificity, respectively. While colloidal gold is currently the most-used label, other detection systems are being developed. Carbon nanoparticles (CNPs) demonstrate outstanding features to improve the sensitivity of this technology by producing an increased contrast in the paper background. Based on the necessity of sensitivity improvement, the aim of this work is a comparative study, in terms of analytical performance, between commercial streptavidin gold nanoparticles (streptAv-AuNPs) and avidin carbon nanoparticles (Av-CNPs) in a nucleic acid lateral flow assay. The visual LOD of the method was calculated by serial dilution of the DNA template, ranging from 0.0 to 7 pg μL-1/1.5 × 104 CFU mL-1). The LFA achieved visual detection of as low as 2.2 × 10-2 pg μL-1 using Av-CNPs and 8.4 × 10-2 pg μL-1 using streptAv-AuNPs. These LODs could be obtained without the assistance of any instrumentation. The results demonstrate that CNPs showed an increased sensitivity, achieving the nanomolar range even by visual inspection. Furthermore, CNPs are the cheapest labels, and the suspensions are very stable and easy to modify.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

The activity of alkaline phosphatase in breast cancer exosomes simplifies the biosensing design

  • Lima Moura, Silio|||0000-0001-8867-6029
  • Pallarès-Rusiñol, Arnau|||0000-0001-9990-148X
  • Sappia, Luciano|||0000-0001-8474-0142
  • Martí, Mercè|||0000-0002-1846-0043
  • Pividori, María Isabel|||0000-0002-5266-7873
This work addresses a biosensor combining the immunomagnetic separation and the electrochemical biosensing based on the intrinsic ALP activity of the exosomes. This approach explores for the first time two different types of biomarkers on exosomes, in a unique biosensing device combining two different biorecognition reaction: immunological and enzymatic. Besides, the intrinsic activity of alkaline phosphatase (ALP) in exosomes as a potential biomarker of carcinogenesis as well as osseous metastatic invasion is also explored. To achieve that, as an in vitro model, exosomes from human fetal osteoblasts are used. It is demonstrated that the electrochemical biosensor improves the analytical performance of the gold standard colorimetric assay for the detection of ALP activity in exosomes, providing a limit of detection of 4.39 mU L-1, equivalent to 105 exosomes μL-1. Furthermore, this approach is used to detect and quantify exosomes derived from serum samples of breast cancer patients. The electrochemical biosensor shows reliable results for the differentiation of healthy donors and breast cancer in- dividuals based on the immunomagnetic separation using specific epithelial biomarkers CD326 (EpCAM) com- bined with the intrinsic ALP activity electrochemical readout.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Biotinylated phosphorus dendrimers as control line in nucleic acid lateral flow tests

  • Vidal, Laura
  • Ben Aissa Soler, Alejandra|||0000-0002-0419-0572
  • Salabert Sabaté, Jordi
  • Jara, José Juan
  • Vallribera, Adelina|||0000-0002-6452-4589
  • Pividori, María Isabel|||0000-0002-5266-7873
  • Sebastián, Rosa María|||0000-0001-5519-9131
Lateral flow assays (LFA) are an affordable, easy-to-use, qualitative rapid test for clinical diagnosis in nonlaboratory environments and low-resource facilities. The control line of these tests is very important to provide a valid result, confirming that the platform operates correctly. A clear, nondiffused line is desirable. The number of colored nanoparticles that reach the control line in a positive test can be very small, and they should all be trapped efficiently by the molecules adsorbed there. In this work, we proposed the use of robust biotinylated dendrimers of two different generations as signal amplifiers in control lines of LFA, able to react with streptavidin-modified gold nanoparticles. Besides the synthesis and characterization, the analytical performance as control lines will be studied, and their response will be compared with other commercially available biotinylated molecules. Finally, the utility of the dendrimer implemented in a NALF (Nucleic Acid Lateral Flow) strip was also demonstrated for detection of the amplicons obtained by double-tagging PCR (polymerase chain reaction) for the detection of E. coli as a model of foodborne pathogen.