Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 9
Encontrada(s) 1 página(s)

Repositorio Institucional de la Universidad de Burgos (RIUBU)
Publicación Artículo científico (JournalArticle)

A new approach based on inversion of a partial least squares model searching for a preset analytical target profile. Application to the determination of five bisphenols by liquid chromatography with diode array detector

  • Arce Antón, Mar
  • Ruiz Miguel, Santiago
  • Sanllorente Méndez, Silvia
  • Ortiz Fernández, Mª Cruz
  • Sarabia Peinador, Luis Antonio
  • Sánchez Pastor, Mª Sagrario
The paper shows a procedure for selecting the control method parameters (factors) to obtain a preset ‘analytical target profile’ when a liquid chromatographic technique is going to be carried out for the simultaneous determination of five bisphenols (bisphenol-A, bisphenol-S, bisphenol-F, bisphenol-Z and bisphenol-AF), some of them regulated by the European Union. The procedure has three steps. The first consists of building a D-optimal combined design (mixture-process design) for the control method parameters, which are the composition of the ternary mobile phase and its flow rate. The second step is to fit a PLS2 model to predict six analytical responses (namely, the resolution between each pair of consecutive peaks, and the initial and final chromatographic time) as a function of the control method parameters. The third final step is the inversion of the PLS2 model to obtain the conditions needed for attaining a preset analytical target profile. The computational inversion of the PLS2 prediction model looking for the Pareto front of these six responses provides a set of experimental conditions to conduct the chromatographic determination, specifically 22% of water, mixed with 58% methanol and 20% of acetonitrile, keeping the flow rate at 0.66 mL min−1. These conditions give a chromatogram with retention times of 2.180, 2.452, 2.764, 3.249 and 3.775 min for BPS, BPF, BPA, BPAF and BPZ, respectively, and excellent resolution among all the chromatographic peaks. Finally, the analytical method is validated under the selected experimental conditions, in terms of trueness and precision. In addition, the detection capability for the five bisphenols were: 596, 334, 424, 458 and 1156 μg L−1, with probabilities of false positive and of false negative equal to 0.05., Spanish MINECO (AEI/FEDER, UE) and Consejería de Educación de la JCyL through projects CTQ2017-88894-R and BU052P20, co-financed with European Regional Development Funds
Repositorio Institucional de la Universidad de Burgos (RIUBU)
Publicación Artículo científico (JournalArticle)

A modified entropy-based performance criterion for class-modelling with multiple classes

  • Valencia García, Olga
  • Ortiz Fernández, Mª Cruz
  • Sánchez Pastor, Mª Sagrario
  • Sarabia Peinador, Luis Antonio
The paper presents a new proposal for a single overall measure, the diagonal modified confusion entropy (DMCEN), to assess the performance of class-models jointly computed for several classes, a versatile index regarding sensitivity and specificity, and that supports class weighting. The characteristics of the proposed figure of merit are illustrated as against other usual performance measures and show how the index is more sensitive to the variations in the class-models than similar published indexes. Besides, a benchmark value representing a random modelling is also defined for DMCEN to be used as initial level to assess the quality of the built class-models. Furthermore, systematic comparisons have been conducted by using the degree of consistency C and the degree of discriminancy D when comparing the proposed DMCEN to the usual total efficiency (a geometric mean between sensitivity and specificity). Simulations show that, for a hundred thousand sensitivity/specificity matrices with four categories, C is almost 0.7 on average, well above the needed 0.5, and there is more than 62% probability that DMCEN detects differences when the total efficiency does not. Illustration of the application of the index is shown with an experimental data set with four categories., Spanish Ministerio de Ciencia, Innovaci on y Universidades (AEI) and Consejería de Educación de la Junta de Castilla y León through projects CTQ2017-88894-R and BU052P20 respectively (both co-financed with European Regional Development Funds)
Repositorio Institucional de la Universidad de Burgos (RIUBU)
Publicación Artículo científico (JournalArticle)

Method operable design region obtained with a partial least squares model inversion in the determination of ten polycyclic aromatic hydrocarbons by liquid chromatography with fluorescence detection

  • Arce Antón, Mar
  • Sanllorente Méndez, Silvia
  • Ruiz Miguel, Santiago
  • Sánchez Pastor, Mª Sagrario
  • Sarabia Peinador, Luis Antonio
  • Ortiz Fernández, Mª Cruz
A chromatographic method with the Analytical Quality by Design (AQbD) methodology is developed for the simultaneous determination by HPLC-FLD of ten PAHs (naphthalene, phenanthrene, anthracene, flu- oranthene, pyrene, chrysene, benzo[a]anthracene, perylene, benzo[b]fluoranthene, and benzo[a]pyrene), widely spread in the environment. The construction of the Method Operable Design Region (MODR) is conducted, for the first time, via the inversion of a multiresponse Partial Least Squares (PLS2) model, which is needed to maintain the correlations among the Critical Method Parameters (CMP), among the Critical Quality Attributes (CQA), and the covariance between one another. The five CMP considered were the composition of the mobile phase (water, methanol, acetonitrile), flow rate, and column temperature. The eight CQA were linked to resolution between peaks recorded in the same emission wavelength (greater than 1.4) and the total time (less than 15 minutes). By systematic use of experimental design and parallel coordinates plots to explore the Pareto optimal front obtained with the PLS2 model inversion, the computed MODR is formed by convex combinations of eight specific settings of Critical Method Parameters that have a mobile phase with percentages of water between 37 and 38 %, of methanol from 13 and 22 %, and of acetonitrile between 41 and 49 %, together with a flow rate between 1.47 and 1.50 mL min −1 , and column temperature between 41.9 and 44.0 °C in their adequate combinations. All the chromatographic peaks are well resolved, with total time varying between 12.96 and 15.66 min inside the estimated MODR and the analytical method is accurate with CC βbetween 0.9 and 7.0 μg L −1 with probability of both false positive and false negative equal to 0.05., Research projects CTQ2017-88894-R and BU052P20, financed by the Spanish Ministerio de Ciencia, Innovación y Universidades (AEI/FEDER, UE) and Consejería de Educación de la Junta de Castilla y León, both cofinanced with European Development Funds. M.M. Arce wishes to thank Junta de Castilla y León for her postdoctoral contract through BU052P20 project.
Repositorio Institucional de la Universidad de Burgos (RIUBU)
Publicación Artículo científico (JournalArticle)

Determination of polymer additive residues that migrate from coffee capsules by means of stir bar sorptive extraction-gas chromatography-mass spectrometry and PARAFAC decomposition

  • Valverde Som, Lucía
  • Reguera Alonso, Celia
  • Herrero Gutiérrez, Ana
  • Sarabia Peinador, Luis Antonio
  • Ortiz Fernández, Mª Cruz
This paper reports on the difficulties encountered when developing an analytical method for ultra-trace determination, in a complex matrix, of plastic additive residues which are ubiquitous in the laboratory. The simultaneous qualitative and quantitative determination of an antioxidant (2,6-di-tert-butyl-4-methyl-phenol, BHT), an UV stabilizer (benzophenone, BP), and a plasticizer (diisobutyl phthalate, DiBP), released from plastic capsules is carried out in coffee by means of GC–MS and parallel factor analysis decomposition. Stir bar sorptive extraction is used to extract and concentrate the analytes. Coffee samples are prepared with Milli-Q water, which contains residues of the target compounds, which can be significant for ultra-trace analysis and should be subtracted. In addition, matrix effect exits in coffee, so standard addition method is used. The residue concentrations released from the coffee capsules into the solid coffee are around 3, 1, and 12 μg kg−1 of BHT, BP and DiBP, respectively., Spanish MINECO (AEI/FEDER, UE) through project CTQ2017-88894-R and by Consejería de la Junta de Castilla y León through project BU052P20 (both co-financed with European FEDER funds). L. Valverde-Som thanks JCyL for her postdoctoral contract through BU052P20 project.
Repositorio Institucional de la Universidad de Burgos (RIUBU)
Publicación Artículo científico (JournalArticle)

Procedure to explore a ternary mixture diagram to find the appropriate gradient profile in liquid chromatography with fluorescence detector. Application to determine four primary aromatic amines in napkins

  • Arce Antón, Mar
  • Castro Reigía, David
  • Sarabia Peinador, Luis Antonio
  • Ortiz Fernández, Mª Cruz
  • Sanllorente Méndez, Silvia
The purpose of this work is to develop a tool to search for a gradient profile with ternary or binary mixtures in liquid chromatography, that can provide well-resolved chromatograms in the shortest time for multianalyte analysis. This approach is based exclusively on experimental data and does not require a retention time model of the compounds to be separated. The methodology has been applied for the quantification of four primary aromatic amines (PAAs) using HPLC with fluorescence detector (FLD). Aniline (ANL), 2,4-diaminotoluene (TDA), 4,4 -methylenedianiline (MDA) and 2-aminobiphenyl (ABP) have been selected since their importance in food contact materials (FCM). In order to achieve that, partial least squares (PLS) models have been fitted to relate CMP (control method parameters) and CQA (critical quality attributes). Specifically, PLS models have been fitted using 30 experiments for each one of the four CQA (resolution between peaks and total elution time), considering 33 predictor variables (the composition of the methanol and acetonitrile in the mobile phase and the time of each one of the 11 isocratic segments of the gradient). These models have been used to predict new candidate gradients, and then, some of those predictions (the ones with resolutions above 1.5, in absolute value, and final time lower than 20 min) have been experimentally validated. Detection capability of the method has been evaluated obtaining 1.8, 189.4, 28.8 and 3.0 μg L−1 for ANL, TDA, MDA and ABP, respectively. Finally, the application of chemometric tools like PARAFAC2 allowed the accurate quantification of ANL, TDA, MDA and ABP in paper napkins in the presence of other interfering substances coextracted in the sample preparation process. ANL has been detected in the three napkins analysed in quantities between 33.5 and 619.3 μg L−1, while TDA is present in only two napkins in quantities between 725.9 and 1908 μg L−1. In every case, the amount of PAAs found, exceeded the migration limits established in European regulations., The authors thank the Consejería de Educación de la Junta de Castilla y León for financial support through project BU052P20, cofinanced with FEDER funds. M.M. Arce wish to thank JCyL for her postdoctoral contract through project BU052P20.
Repositorio Institucional de la Universidad de Burgos (RIUBU)
Publicación Artículo científico (JournalArticle)

Simultaneous class-modelling in chemometrics: A generalization of Partial Least Squares class modelling for more than two classes by using error correcting output code matrices

  • Valencia García, Olga
  • Ortiz Fernández, Mª Cruz
  • Ruiz Miguel, Santiago
  • Sánchez Pastor, Mª Sagrario
  • Sarabia Peinador, Luis Antonio
The paper presents a new methodology within the framework of the so-called compliant class-models, PLS2-CM, designed with the purpose of improving the performance of class-modelling in a setting with more than two classes. The improvement in the class-models is achieved through the use of multi-response PLS models with the classes encoded via Error-Correcting Output Codes (ECOC), instead of the traditional class indicator variables used in chemometrics. The proposed PLS2-CM entails a decomposition of a class-modelling problem into a series of binary learners, based on a family of code matrices with different code length, which are evaluated to obtain simultaneous compliant class-models with the best performance. The methodology develops both a new encoding system, based on multi-criteria optimization to search for optimal coding matrices, and a new decoding system, based on probability thresholds to assign objects to classmodels. The whole procedure implies that the characteristics of the dataset at hand affect the final selection of the coding matrix and therefore of built class-models, thus giving rise to a data-driven strategy. The application of PLS2-CM to a variety of cases (controlled data, experimental data and repository datasets) results in an enhanced class-modelling performance by means of the suggested procedure, as measured by the DMCEN (Diagonal Modified Confusion Entropy) index and by sensitivity-specificity matrices. The predictive ability of the compliant class-models has been evaluated., This work is part of the project with reference BU052P20 financed by Junta de Castilla y Leon, Conserjería de Educacion with the aid of European Regional Development Funds.
Repositorio Institucional de la Universidad de Burgos (RIUBU)
Publicación Artículo científico (JournalArticle)

A new multi-factor multi-objective strategy based on a factorial presence-absence design to determine polymer additive residues by means of head space-solid phase microextraction-gas chromatography-mass spectrometry

  • Valverde Som, Lucía
  • Herrero Gutiérrez, Ana
  • Reguera Alonso, Celia
  • Sarabia Peinador, Luis Antonio
  • Ortiz Fernández, Mª Cruz
A new multi-factor multi-objective strategy to approach the joint assessment of the effect of six experimental factors in the determination by head space-solid phase microextraction-gas chromatography-mass spectrometry (HS-SPME-GC-MS) of eight different additives commonly used in the plastic packaging manufacturing is proposed in this work. Five HS-SPME experimental factors, both qualitative and quantitative, are explored: the type of fiber, addition of salt, extraction and desorption time, and extraction temperature. The effect of these factors is studied through a factorial presence-absence model, that include interactions, using a D-optimal design. As a result, the number of experiments is reduced from 128, full factorial design, to 14. The effect of carrying out the measurements in different experimental sessions is considered by including a blocking factor. The response for each compound is estimated in the experimental domain and then the best experimental conditions are chosen by using Pareto front. Parallel coordinates are employed to show the conflicting conditions intrinsic to a multiobjective analysis when compounds of different nature are extracted by HS-SPME. Parallel factor analysis 2 (PARAFAC2) decomposition is used because it makes the determination of target compounds in the presence of unknown interferents possible, which enables the unequivocal identification of target compounds according to official regulations. The developed method is applied to determine 2,6-di-tert-butyl-4-methyl-phenol (BHT), benzophenone (BP), bis(2-ethylhexyl) adipate (DEHA), diethyl phthalate (DEP), diisobutyl phthalate (DiBP), dibutyl phthalate (DBP), benzyl butyl phthalate (BBP) and bis(2-ethylhexyl) phthalate (DEHP). The level of these compounds found in nine types of bottled natural still and sparkling mineral waters is very low, so the compounds were not present in quantities that may be injurious to human health., The authors thank the financial support provided by Consejería de la Junta de Castilla y Leon ´ (JCyL) through project BU052P20 co-financed with European FEDER funds. Lucía Valverde-Som thanks JCyL for her postdoctoral contract through this project.
Repositorio Institucional de la Universidad de Burgos (RIUBU)
Publicación Artículo científico (JournalArticle)

Univariate data analysis versus multivariate approach in liquid chromatography. An application for melamine migration from food contact materials

  • Arce Antón, Mar
  • Ortiz Fernández, Mª Cruz
  • Sanllorente Méndez, Silvia
The aim of this work is focused on the melamine migration from food contact materials (FCMs), considering data obtained from univariate analysis versus that obtained from multivariate approach in liquid chromatography coupled to diode array detector. Plastic food contact materials are made from monomers and additives. Moreover, non-intentionally added substances (NIAS) can be part of the composition of the FCM: raw material impurities or process by-products, inks or adhesives. Any compound present within a FCM can migrate to foodstuff. Specific migration of some substances from plastic FCMs to food/simulant is limited by European legislation in force (Commission Regulation No 10/2011). Quantification of analytes in migration samples through a univariate analysis could lead to erroneous results. As an example, in liquid chromatography NIAS can interfere when coeluting with analytes or when they have close retention time. In that case, an overestimation would happen and the verification of the compliance of the specific migration limit (SML) of a substance would be incorrect. A solution to the problem can be found in the application of a chemometric tool with the second-order advantage, which allows the unequivocal identification of analytes. Specifically, for this work, PARAFAC/ PARAFAC2 decomposition technique along with tensors arranged from HPLC-DAD data of migration (test and kinetics) samples were used for the identification and quantification of melamine. Results of melamine quantity found in migration samples from five types of melaware by means of a multivariate approach were compared to results obtained with a univariate data analysis carried out with values of chromatographic peak area as response. The comparison reveals that in test samples, univariate analysis supposes an overestimation in the quantity of melamine of 30 % on average, with respect of the concentration obtained from the multivariate approach. Besides, in kinetics samples it is remarkable that for one migration cycle the melamine found was 10 times above the one that obtained with PARAFAC decomposition. Summing up, multivariate data analysis of migration samples supposes a great advantage in order to comply with the established regulation about migrants and to decrease the false non-compliant results., The authors thank the Consejería de Educación de la Junta de Castilla y León, Spain for financial support through project BU052P20, cofinanced with FEDER funds. M.M. Arce wish to thank JCyL for her postdoctoral contract through project BU052P20.
Repositorio Institucional de la Universidad de Burgos (RIUBU)
Publicación Artículo científico (JournalArticle)

Logical analysis of sample pooling for qualitative analytical testing

  • Sarabia Peinador, Luis Antonio
  • Valencia García, Olga
  • Ortiz Fernández, Mª Cruz
When the prevalence of positive samples in a whole population is low, the pooling of samples to detect them has been widely used for epidemic control. However, its usefulness for applying analytical screening procedures in food safety (microbiological or allergen control), fraud detection or environmental monitoring is also evident. The expected number of tests per individual sample that is necessary to identify all ‘positives’ is a measure of the efficiency of a sample pooling strategy. Reducing this figure is key to an effective use of available resources in environmental control and food safety. This reduction becomes critical when the availability of analytical tests is limited, as the SARS-CoV-2 pandemic showed. The outcome of the qualitative analytical test is binary. Therefore, the operation governing the outcome of the pooled samples is not an algebraic sum of the individual results but the logical operator (‘or’ in natural language). Consequently, the problem of using pooled samples to identify positive samples naturally leads to proposing a system of logical equations. Therefore, this work suggests a new strategy of sample pooling based on: i) A half-fraction of a Placket-Burman design to make the pooled samples and ii) The logical resolution, not numerical, to identify the positive samples from the outcomes of the analysis of the pooled samples. For a prevalence of ‘positive’ equal to 0.05 and 10 original samples to be pooled, the algorithm presented here results in an expected value per individual equal to 0.37, meaning a 63% reduction in the expected number of tests per individual sample. With sensitivities and specificities of the analytical test ranging from 0.90 to 0.99, the expected number of tests per individual ranges from 0.332 to 0.416, always higher than other pooled testing algorithms. In addition, the accuracy of the algorithm proposed is better or similar to that of other published algorithms, with an expected number of hits ranging from 99.16 to 99.90%. The procedure is applied to the detection of food samples contaminated with a pathogen (Listeria monocytogenes) and others contaminated with an allergen (Pistachio) by means of Polymerase Chain Reaction, PCR, test., This work was supported by Consejería de Educación de la Junta de Castilla y León through project BU052P20 co-financed with European Regional Development Funds. The authors thank Dr. Laura Rubio for applying the double-blind protocol to dope the samples and AGROLAB S.L.U, Burgos (Spain) for the careful preparation of the pooled samples.