Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 6
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Monitoring holograms for therapeutic ultrasound using passive cavitation beamforming

  • Lamothe, Nathalie
  • Andrés-Bautista, Diana
  • Pineda-Pardo, J.A.
  • CARRIÓN GARCÍA, ALICIA|||0000-0002-0630-6065
  • Camarena Femenia, Francisco|||0000-0002-6713-1414
  • Jimenez, Noe|||0000-0002-6539-670X
[EN] Acoustic holograms can generate cavitation patterns of complex spatial distribution by shaping and steering the focal spot of therapeutic ultrasound systems. However, when monitoring these systems by passive cavitation detection, off-axis therapeutical targets and the receiver directivity may not be aligned. In this paper, we present passive cavitation beamforming to monitor a therapeutical ultrasound system using holograms targeted to arbitrary locations, in which both therapeutic and passive cavitation monitoring systems use 3D-printed acoustic lenses. The therapeutic system uses an acoustic hologram to focus the ultrasound beam on the target, which is off-axis. Then, a second lens is designed to beamform the cavitation signals which emerge from the therapeutic target, steering the directivity of the passive cavitation detector in the direction of the therapeutic focus and, in addition, compensating for skull aberrations. The system is experimentally tested with an ex-vivo macaque skull and a blood vessel phantom with microbubbles. In addition, results are compared with a standard confocal configuration and an off-axis configuration in the absence of the monitor lens. A parametric study is performed by varying the amplitude of the emitted signal and the impact on the behaviour of the microbubbles is analysed based on the cavitation index values. Results show that monitoring holograms align the passive cavitation detector response with the focal spot of the targeted therapeutic transducer. These holograms encode a fixed beamformer for cavitation signals in reception, increasing the sensitivity of cavitation emission at the target. In this way, cavitation doses can be used to locally monitor the cavitation activity of microbubbles, thus opening a new path to low-cost monitoring of therapeutic ultrasound systems., This research has been supported by the Ministerio Español de Ciencia e Innovación and the Ministerio de Universidades grants FJC2019-040453-I, RYC2021-034920-I, FPU19/00601 and Agencia Estatal de Investigación grants PID2022-142719OB-C21 and CNS2023-145707 funded by MCIN/AEI/10.13039/501100011033; Agència Valenciana de la Innovació grants INNVA2/2022/11 and INNEST/2022/345; Generalitat Valenciana grants EDGJID/2021/189, CIGE/2021/175, CIAICO/2023/052, CIPROM/2021/003, FDEGENT/2019/004 and IDIFEDER/2021/004.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Real-time ultrasound shear wave elastography using a local phase gradient

  • González-Mateo, Enrique
  • Camarena Femenia, Francisco|||0000-0002-6713-1414
  • Jimenez, Noe|||0000-0002-6539-670X
[EN] Background and Objective: Current approaches for ultrasound spectral elastography make use of block processing, resulting in long computational times. This work describes a real-time, robust, and quantitative imaging modality to map the elastic and viscoelastic properties of soft tissues using ultrasound. Methods: This elastographic technique relies on the spectral estimation of the shear-wave phase speed by combining a local phase-gradient method and angular filtering. We first apply directional filtering in the spatio-temporal frequency domain for providing one-way, smooth, and harmonic displacement maps in the frequency range of interest. Thanks to this, we can apply a simple, fast, and local phase gradient approach to obtain the axial and lateral components of the wavevector, which are linked to phase velocity and soft-tissue elasticity and viscoelasticity. The technique is validated numerically and experimentally using a 7.6 MHz ultrasound probe, tested in calibrated soft-tissue phantoms and ex vivo liver tissues. The method is compared with state-of-the-art spectral methods. Results: The technique significantly reduces the computation time, e.g., the reconstruction time for a 155 × 315-pixel phase-velocity map was 0.16 s, while local-phase velocity-imaging techniques was 156.73 s for 2D implementation and 13.56 s for the 1D version, a reduction between two and three orders of magnitude, while showing a similar accuracy and resolution than standard methods. Conclusions: This approach eliminates the need for block processing that may limit the spatial resolution and computational time of the velocity map. In this way, the phase gradient elastography method is revealed as an efficient and robust approach for real-time spectral elastography., This research has been supported by the Ministerio de Ciencia, Innovacion y Universidades, Spain and Agencia Estatal de Investigacion, Spain grants RYC2021-034920-I, PID2022-142719OB-C21, PID2019- 111436RB-C22 and CNS2023-145707 funded by MCIN/AEI/10.13039/501100011033; Agencia Valenciana de la Innovacio, Spain grants INNVA2/2022/11, INNVA1/2022/37, INNVA1/2020/92, and Generalitat Valenciana, Spain grants CIAICO/2023/052 and IDIFEDER/2021/004.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Bidirectional Lambertian Scatterers Using Acoustic Holograms for the Simultaneous Control of Reflected and Transmitted Wavefronts

  • Ballestero, Eric
  • Groby, Jean Philippe
  • Rodríguez-Sendra, Josep|||0000-0001-5344-6602
  • Romero-García, Vicente|||0000-0002-3798-6454
  • Jimenez, Noe|||0000-0002-6539-670X
[EN] Acoustic holography enables the creation of tailored spatiotemporal wavefield distributions. In this study, the design of acoustic holograms that simultaneously control both the reflected and the transmitted fields are presented. This is accomplished through the use of a bidirectional metasurface, which encodes the phase of a desired wavefront in a discrete spatial distribution of monolithic sub-elements. This approach is employed in particular to design an optimized hologram that behaves as an ideal Lambertian scatter for both reflection and transmission. The design follows a quadratic-residue sequence, with theoretical results validated both numerically and experimentally. It is observed that this kind of structure produces a uniform scattering response, with a high diffusion coefficient of approximately 0.7 and a correlation scattering coefficient of 0.98 in both transmission and reflection. The hologram demonstrates the potential to significantly reduce imaging artefacts in ultrafast ultrasound techniques in strongly reverberating environments, as evidenced by examples., E.-B. and J.-P. G. contributed equally to this work. The collaboration between the authors of this article was made possible thanks to Institut d'Acoustique - Graduate School (IAGS) project (ANR-17-EURE-0014) from the Laboratoire d'Acoustique du l'Universite du Mans (LAUM) for the support and mobility. The authors gratefully acknowledge the ANR-RGC METARoom (ANR-18-CE08-0021) project and N.J and V.R-G acknowledges financial support from Conselleria de Innovacion, Universidades, Ciencia y Sociedad Digital de la Generalitat Valenciana through project CIAICO/2022/052 of the Programa para la promocion de la investigacion cientifica, el desarrollo tecnologico y la innovacion en la Comunitat Valenciana. This research has been supported by the Ministerio Espanol de Ciencia e Innovacion grant RYC2021-034920-I and Agencia Estatal de Investigacion grants PID2022-142719OB-C21 and CNS2023-145707 funded by MCIN/AEI/10.13039/501100011033 and grant PID2023-146237NB-I00 funded by MICIU/AEI/ 10.13039/501100011033. Funding for open access charge: CRUE-Universitat Politecnica de Valencia.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Real-time ultrasound shear wave elastography using a local phase gradient

  • González-Mateo, Enrique
  • Camarena, Francisco
  • Jiménez González, Noé
[Background and Objective] Current approaches for ultrasound spectral elastography make use of block processing, resulting in long computational times. This work describes a real-time, robust, and quantitative imaging modality to map the elastic and viscoelastic properties of soft tissues using ultrasound., [Methods] This elastographic technique relies on the spectral estimation of the shear-wave phase speed by combining a local phase-gradient method and angular filtering. We first apply directional filtering in the spatio-temporal frequency domain for providing one-way, smooth, and harmonic displacement maps in the frequency range of interest. Thanks to this, we can apply a simple, fast, and local phase gradient approach to obtain the axial and lateral components of the wavevector, which are linked to phase velocity and soft-tissue elasticity and viscoelasticity. The technique is validated numerically and experimentally using a 7.6 MHz ultrasound probe, tested in calibrated soft-tissue phantoms and ex vivo liver tissues. The method is compared with state-of-the-art spectral methods., [Results] The technique significantly reduces the computation time, e.g., the reconstruction time for a 155 × 315-pixel phase-velocity map was 0.16 s, while local-phase velocity-imaging techniques was 156.73 s for 2D implementation and 13.56 s for the 1D version, a reduction between two and three orders of magnitude, while showing a similar accuracy and resolution than standard methods., [Conclusions] This approach eliminates the need for block processing that may limit the spatial resolution and computational time of the velocity map. In this way, the phase gradient elastography method is revealed as an efficient and robust approach for real-time spectral elastography., This research has been supported by the Ministerio de Ciencia, Innovación y Universidades, Spain and Agencia Estatal de Investigación, Spain grants RYC2021-034920-I, PID2022-142719OB-C21, PID2019-111436RB-C22 and CNS2023-145707 funded by MCIN/AEI/10.13039/501100011033; Agencia Valenciana de la Innovació, Spain grants INNVA2/2022/11, INNVA1/2022/37, INNVA1/2020/92, and Generalitat Valenciana, Spain grants CIAICO/2023/052 and IDIFEDER/2021/004., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Can we design transcranial acoustic holograms without ionizing radiation?

  • Eroles-Simó, Alba
  • Vegas-Luque, Víctor
  • Carrión, Alicia
  • Pineda-Pardo, José A.
  • Camarena, Francisco
  • Jiménez González, Noé
The 2025 IEEE International Ultrasonics Symposium, Conference, 5-18 September 2025, Utrecht, Netherlands., Acoustic holography is a promising technique in transcranial therapeutic ultrasound, enabling precise wavefront shaping to compensate skull-induced aberrations using single-element transducers. Traditionally, the design of these holograms has relied on full-wave simulations based on acoustic properties extracted from computed tomography (CT), exposing the patient to ionizing radiation. In this study, we present a radiation-free alternative by employing Zero Echo Time (ZTE) magnetic resonance imaging (MRI), capable of capturing signal from bone tissue. By establishing a linear correlation between ZTE intensity values and CT Hounsfield units, we generate pseudo-CT images suitable for acoustic simulation. Simulated results on 5 patients demonstrate that holograms based on pseudo-CT data achieve a peak pressure at focus with mean reduction of 5.38% and about 1 mm spatial deviation respect to those obtained using CT data. This approach provides a viable pathway for implementing safe, patient-specific, wearable holographic systems for transcranial ultrasound therapy without the need of ionizing radiation., This research has been founded by Generalitat Valenciana through grants INVEST/2023/553, EDGJID/2021/189, INNEST/2022/345 and CIAICO/2023/052. This research has been founded by the Ministerio Español de Ciencia e Innovación y el Ministerio de Universidades with grants PREP2022-000156 by the Agencia Estatal de Investigación, PID2022-142719OB-C21 and CNS2023-145707 founded by MCIN/AEI/10.13039/501100011033 and by the FSE+., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

MLS-Coded ARF Excitation for Noise-Resilient Shear Wave Elastography

  • González-Mateo, Enrique
  • Urban, Matthew
  • Jiménez González, Noé
The 2025 IEEE International Ultrasonics Symposium, Conference, 5-18 September 2025, Utrecht, Netherlands., This study proposes a shear wave elastography (SWE) technique based on maximal length sequence (MLS) coded acoustic radiation force (ARF) excitation combined with frequency-domain pulse compression. The goal is to enable robust SWE measurements under low-voltage conditions where conventional single-push (SP) methods suffer from low signal-to-noise ratio (SNR) due to safety constraints on acoustic output. A 127-bit MLS sequence was used to modulate the ARF push, distributing the energy over long ARF excitations while maintaining a low peak voltage. After compression, the induced displacement fields exhibited impulse-like profiles with enhanced SNR. In vivo measurements were performed on the human biceps brachii using three excitation modes: high-voltage SP (60 V), low- voltage SP (20 V), and low-voltage MLS-coded excitation (20 V). Under low-voltage conditions, MLS increased the SNR from - 3.5 dB (SP) to 5.6 dB, recovered accurate group velocity estimates (5.26 m/s, R2 = 0.93), and preserved stable phase velocity profiles up to 900 Hz. In contrast, low-voltage SP produced unreliable group velocity (−8.83 m/s, R2 = 0.15) and degraded phase velocity at high frequencies. The results demonstrate that MLS-coded excitation enables high-quality SWE at reduced acoustic exposure, expanding its applicability to safety-sensitive tissues such as neonatal or lung., This research has been supported by the Ministerio Espanol de Ciencia e Innovacion grant RYC2021-034920-I, by the Consejo Superior de Investigaciones Científicas grant IMOVE24009 and by the Agencia Estatal de Investigacion grants PID2022-142719OB-C21 and CNS2023-145707 funded by MCIN/AEI/10.13039/501100011033; Agencia Valenciana de la Innovaci ` o´ grants INNVA2/2022/11 and INNEST/2022/345., Peer reviewed