Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Use of a voltammetric electronic tongue for predicting levels of nerve agent mimics

  • Campos Sánchez, Inmaculada
  • Soto Camino, Juan
  • Gil Sánchez, Luís|||0000-0003-3453-5559
  • Martínez-Máñez, Ramón|||0000-0001-5873-9674
  • Vivancos, José-Luis|||0000-0002-8524-5466
[EN] An electronic tongue (ET) based on pulse voltammetry containing a set of eight metallic electrodes (Au, Pt, Ir, Rh, Cu, Co, Ni and Ag) encapsulated on a stainless steel cylinder has been used to discriminate and predict levels of nerve agent mimics in aqueous environments. Analysis including principal component analysis (PCA) and partial least square techniques (PLS) have been applied for data management and prediction models. A good discrimination from other organophosphorous derivatives was found for the nerve agent simulants diethyl-chlorophosphate (DCP) and diethyl-cyanophosphate (DCNP)., We thank the Ministerio de Ciencia y Tecnologia (project CTQ2006-15456-C04-01), and Universidad Politecnica de Valencia (project PAID-06-07-3243) for support. I.C. thanks the Universidad Politecnica de Valencia for a Doctoral Fellowship.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Monitoring of physical-chemical and microbiological changes in fresh pork meat under cold storage by means of a potentiometric electronic tongue

  • Gil Sánchez, Luís|||0000-0003-3453-5559
  • Barat Baviera, José Manuel|||0000-0001-8487-7114
  • Martínez-Máñez, Ramón|||0000-0001-5873-9674
  • Garcia-Breijo, Eduardo|||0000-0002-9745-8485
  • Toldrá Vilardell, Fidel
  • Baigts Allende, Diana Karina
  • Soto Camino, Juan
  • Aristoy Albert, Mª Concepcion
  • Llobet Valero, Eduard
This work describes the correlation found along 10 days between potentiometric measurements obtained by using an electronic tongue and the variation in certain physicochemical, microbial and biochemical parameters measured on a whole piece of pork loin stored under refrigeration. The electronic tongue consists of a set of six electrodes made of Au, Ag, Cu, Pb, Zn and C, and a reference electrode. Through the use of various multivariate analysis techniques, such as: PCA and two types of artificial neural networks (i.e. multilayer perceptron (MLP) and fuzzy ARTMAP) it was found that it is possible to determine the time elapsed in relation to the degradation of the loin by using simple potentiometric measurements. Additionally, in the same pork sample used to measure redox potentials with the electronic tongue, the following parameters were also determined; pH, microbial count, concentrations of inosine 5'-monophosphate (IMP), inosine (Ino) and hypoxanthine (Hx). Through the use of PLS analysis, it was found a rather good correlation between pH and the potentiometric data. Also a remarkable correlation was observed between the measures carried out with the electronic tongue and the so-called K-index that simultaneously measures the variation in the adenosine triphosphate (ATP) degradation products. These results suggest that this simple, or a similar electronic tongue, could be useful for the undemanding qualitative or semi-quantitative evaluation of freshness in meat samples in a wide range of situations. © 2010 Elsevier Ltd. All rights reserved., We would like to thanks the Spanish Government for support (Project CTQ2006-15456-C04-01/BQU and AGL2007-65379-C02-01 and 02/ALI). This work has been partially carried out under Associated Unit framework between IIAD (UPV) and IATA (CSIC).