Pasar al contenido principal

NUEVOS TRANSDUCTORES BASADOS EN NANOMATERIALES PARA SENSORICA ELECTROQUIMICA EN SISTEMAS MICROFLUIDICOS ELECTROCINETICOS.

CTQ2011-28135

•
Nombre agencia financiadora Ministerio de Ciencia e Innovación
Acrónimo agencia financiadora MICINN
Programa Programa Nacional de Proyectos de Investigación Fundamental
Subprograma Subprograma de Proyectos de Investigación Fundamental no Orientada
Convocatoria Proyectos I+D
Año convocatoria 2011
Plan Estatal 2008-2011 Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica
Unidad de gestión Subdirección General de Proyectos de Investigación
Centro beneficiario UNIVERSIDAD DE ALCALA
Identificador persistente http://dx.doi.org/10.13039/501100004837

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

Docta Complutense
Publicación Artículo científico (JournalArticle)

Carbon Nanotubes Press-Transferred on PMMA Substrates as Exclusive Transducers for Electrochemical Microfluidic Sensing

  • Vilela García, Diana
  • Garoz Ruiz, Jesús
  • Colina, Álvaro
  • González, María Cristina
  • Escarpa, Alberto
Novel single-walled carbon nanotube press-transfer electrodes (SW-PTEs) for microfluidic sensing are proposed. In this approach, carbon nanotubes are press-transferred on poly- (methyl methacrylate) (PMMA) substrates and are easily coupled to microfluidic chips and act as the exclusive transducer in electrochemical sensing. The detector design consisted of a presstransferred SW film (7 mm × 1 mm) positioned and centered on the PMMA substrate (33 mm × 9 mm). The analytical performance of the SW-PTEs was deeply evaluated using two commercial SWs sources and employing a mixture of dopamine and catechol as model analytes. Analyte detection was influenced by the volume of commercial SW dispersion used in the fabrication of SW-PTEs, with 5 mL taken from a dispersion of 0.5 mg/100 mL being the most favorable volume. In addition, excellent repeatability (relative standard deviation (RSD) of ≤7%, n = 5), interelectrodes reproducibility (RSD ≤ 9%, n = 5), and an extreme resistance to fouling were obtained even after 1 h of microchip analysis with RSD values of ≤4% and ≤9% (n = 15) for migration times and peak heights, respectively. Good sensitivity, remarkable signal-to-noise characteristics, and a well-defined linear concentration dependence (r ≥ 0.990) was also obtained, which allowed these novel detectors to be considered as valuable tools for quantitative analysis. Analytical characterization of the SW-PTEs by field-emission scanning electron microscopy (FESEM) revealed individual bundles of SWs that were highly ordered over the PMMA at the background where the SW bundles were embedded on the PMMA substrate, giving the electrode a high stability. Furthermore, the laboratory-fabricated SW-PTEs can be afforded in any laboratory since they do not require clean-room facilities and are highly compatible with microfluidic scale, mass production, and disposability. In addition, the proposed approach draws new and exciting horizons for electrochemical microfluidic sensing, such as the use of other pure or hybrid nanomaterials and also the possibilities to incorporate biomolecules for highly selective sensing
Docta Complutense
Publicación Artículo científico (JournalArticle)

Gold-nanosphere formation using food sample endogenous polyphenols for in-vitro assessment of antioxidant capacity

  • Vilela García, Diana
  • González, María Cristina
  • Escarpa, Alberto
In this work it was demonstrated that sample endogenous polyphenols are selectively driving the gold-nanoparticle (AuNPs)-formation process when representative food samples were used as natural sources of reducing compounds. The process of AuNPs formation was characterized by UV–visible spectroscopy and was described by a sigmoidal curve (R 2 ≥ 0.990) which gave information about the polyphenol concentration at which the localized surface plasmon resonance (LSPR) absorption reached its half-value, X50c, and about AuNPs production per polyphenol concentration unit, K AuNPs. The behavior of phenolic acids was different, with lower X 50c and higher K AuNPs values than flavonoids. For the food samples tea, apple, pear, wine, and honey X50c values were 0.22, 7.3, 11.5, 20.4, 30.3, and 53.5 (mg mL−1) and K AuNPs values were 28.7, 0.70, 0.60, 0.20, 0.14, and 0.10 (mg−1 mL), respectively. Excellent correlation between K AuNPs and total phenolics (TP) was obtained (r = 0.98, p-value < 0.05), implying K AuNPs is a novel marker for evaluation of food sample antioxidant capacity in vitro. The K AuNPs values of samples indicated their antioxidant capacity was in the order: tea > apple > pear > wine > honey. The reproducibility of the AuNPs formation approach was excellent, not only for polyphenol standards (RSD < 6 % for X50c and RSD < 11 % for K AuNPs) but also for food samples (RSD < 9 % for X50c and RSD < 15 % for K AuNPs). Transmission electronic microscopy (TEM) enabled confirmation of the formation of stabilized Au-nanospheres from endogenous polyphenols with very well-defined sizes under 20 nm diameter for all the food samples investigated.
Docta Complutense
Publicación Artículo científico (JournalArticle)

Antioxidant capacity index based on gold nanoparticles formation. Application to extra virgin olive oil samples

  • Della Pelle, Flavio
  • Vilela García, Diana
  • González, María Cristina
  • Lo Sterzo, Claudio
  • Compagnone, Darío
  • Carlo, Michele Del
  • Escarpa, Alberto
A simple gold nanoparticles (AuNPs) based colorimetric assay for the antioxidant activity determination has been developed. The AuNP formation is mediated by extra virgin olive oil (EVOO’s) endogenous polyphenols; the reaction is described by a sigmoidal curve. The ratio KAuNPs/Xc50 (slope of the linear part of the sigmoid/concentration at half value of the absorbance) was found to be the optimal parameter to report the antioxidant capacity with respect to the single KAuNPs or Xc50 values. The obtained data demonstrated that the compounds with ortho-diphenols functionality are most active in reducing gold (III) to gold (0). Thus, intermediate activity was found for gallic acid, while tyrosol (mono-phenols) had a significant lower activity than the others antioxidant compounds (at least one order of magnitude). In the analysis of olive oil samples, a significant correlation among classical methods used to determine antioxidant activity and the proposed parameter was found with R values in the 0.96–0.97 range.