Pasar al contenido principal

DETECCION DE BIOMARCADORES RELACIONADOS CON LA ENFERMEDAD DE ALZHEIMER (AD) MEDIANTE EL USO DE NANOPARTICULAS, ELECTRODOS SERIGRAFIADOS Y MICROELECTRODOS.

CTQ2017-86994-R

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos I+D+i Retos de Investigación
Año convocatoria 2017
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSIDAD DE OVIEDO

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

A monoclonal antibody-based immunosensor for the electrochemical detection of imidacloprid pesticide

  • Pérez-Fernández, Beatriz
  • Mercader Badia, Josep Vicent
  • Checa-Orrego, Brena I.
  • de la Escosura Muñiz, Alfredo
  • Costa-García, Agustín
Imidacloprid (IMD) is one of the most used pesticides worldwide as a systemic insecticide as well as for pest control and seed treatment. The toxic and potential carcinogenic character of IMD makes its monitoring of great relevance in the field of agriculture and environment, so sensitive methodologies for in field analysis are strongly required. In this context, we have developed a competitive immunoassay for the determination of IMD using specific monoclonal antibodies followed by electrochemical detection on screen-printed carbon electrodes (SPCE). The optimized immunosensor exhibited a good reproducibility (RSD of 9%) and a logarithmic response in the range 50-10 000 pM of IMD, with an estimated detection limit (LOD) of 24 pM, which was below the maximum levels allowed by the legislation. High-Performance Liquid Chromatography-Mass Spectrometry-Mass Spectrometry (HPLC-MSMS) and Enzyme-Linked Immunosorbent Assay (ELISA) analysis were also performed for comparison purposes, where the electrochemical immunosensor exhibited a wider range of response and a lower detection limit. Matrix effects below 6.5% were obtained using tap water samples. All these characteristics make our electrochemical immunosensor a valid and advantageous tool for the in field determination of IMD., This work has been supported by the FC-GRUPIN-ID/2015/021 and FC-GRUPIN-ID/2018/000166 projects from the Asturias Regional Government and the CTQ2014–58826-R and CTQ2017–86994-R projects from the Spanish Ministry of Economy and Competitiveness (MINECO). A. de la Escosura-Muñiz acknowledges the Spanish Ministry of Science, Innovation and Universities (MICINN) for the “Ramón y Cajal” Research Fellow (RyC-2016-20299).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Direct competitive immunosensor for Imidacloprid pesticide detection on gold nanoparticle-modified electrodes

  • Pérez-Fernández, Beatriz
  • Mercader Badia, Josep Vicent
  • Abad Fuentes, Antonio
  • Checa Orrego, Brenda I.
  • Costa-García, Agustín
  • de la Escosura Muñiz, Alfredo
A direct competitive immunosensor for the electrochemical determination of Imidacloprid (IMD) pesticide on gold nanoparticle-modified screen-printed carbon electrodes (AuNP-SPCE) is here reported for the first time. Self-obtained specific monoclonal antibodies are immobilized on the AuNP-SPCE taking advantage of the AuNPs biofunctionalization abilities. In our biosensor design, free IMD in the sample competes with IMD conjugated with horseradish peroxidase (IMD-HRP) for the recognition by the antibodies. After that, 3,3′,5,5′-Tetramethylbenzidine (TMB) is enzymatically oxidized by HRP, followed by the oxidized TMB reduction back at the surface of the SPCE. This process gives an associated catalytic current (analytical signal) that is inversely proportional to the IMD amount. The main parameters affecting the analytical signal have been optimized, reaching a good precision (repeatability with a RSD of 6%), accuracy (relative error of 6%), stability (up to one month), selectivity and an excellent limit of detection (LOD of 22 pmol L−1), below the maximum levels allowed by the legislation, with a wide response range (50–10000 pmol L−1). The detection through antibodies also allows to have an excellent selectivity against other pesticides potentially present in real samples. Low matrix effects were found when analysing IMD in tap water and watermelon samples. The electrochemical immunosensor was also validated with HPLC-MS/MS, the reference method used in official laboratories for IMD analysis, through statistical tests. Our findings make the electrochemical immunosensor as an outstanding method for the rapid and sensitive determination of IMD at the point-of-use., This work has been supported by the FC-GRUPIN-ID/2018/000166 project from the Asturias Regional Government and the CTQ2017-86994-R project from the Spanish Ministry Economy and Competitiveness (MINECO). A. de la Escosura-Muñiz acknowledges the Spanish Ministry of Science, Innovation and Universities (MICINN) for the “Ramón y Cajal” Research Fellow (RyC-2016-20299)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Coherent silicon photonic interferometric biosensor with an inexpensive laser source for sensitive label-free immunoassays

  • Leuermann, Jonas
  • Stamenkovic, Vladimir
  • Ramirez-Priego, Patricia
  • Sánchez Postigo, Alejandro
  • Fernández Gavela, Adrián
  • Chapman, Cole A.
  • Bailey, Ryan C.
  • Lechuga, Laura M.
  • Pérez-Inestrosa, Ezequiel
  • Collado, Daniel
  • Halir, Robert
  • Molina Fernández, Íñigo
Over the past two decades, integrated photonic sensors have been of major interest to the optical biosensor community due to their capability to detect low concentrations of molecules with label-free operation. Among these, interferometric sensors can be read-out with simple, fixed-wavelength laser sources and offer excellent detection limits but can suffer from sensitivity fading when not tuned to their quadrature point. Recently, coherently detected sensors were demonstrated as an attractive alternative to overcome this limitation. Here we show, for the first time, to the best of our knowledge, that this coherent scheme provides sub-nanogram per milliliter limits of detection in C-reactive protein immunoassays and that quasi-balanced optical arm lengths enable operation with inexpensive Fabry–Perot-type lasers sources at telecom wavelengths., Horizon 2020 Framework Programme (EuroNanoMed 3-H2020 DrNanoDAII); Ministerio de Economía y Competitividad (2019/PCI 2019-2, CTQ2017-86994-R, SEV-2017-0706); Junta de Andalucía, Proyectos Excelencia-Retos (P18-RT-1453, P18-RT-793); Fondos Europeos de Desarrollo Regional (CTQ2016-75870-P, PID2019-104293GB-I00, RD16/0006/0012, TEC2016-80718-R, UMA18-FEDERJA-007, UMA18-FEDERJA-219); H2020 Marie Skłodowska-Curie Actions (713721)., Peer reviewed
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Coherent silicon photonic interferometric biosensor with an inexpensive laser source for sensitive label-free immunoassays

  • Leuermann, Jonas|||0000-0001-7321-5190
  • Stamenkovic, Vladimir
  • Ramirez Priego, Patricia|||0000-0001-5657-3279
  • Sánchez-Postigo, Alejandro|||0000-0003-4782-0105
  • Fernandez-Gavela, Adrian|||0000-0002-4562-1308
  • Chapman, Cole A.
  • Bailey, Ryan C.
  • Lechuga, Laura M.|||0000-0001-5187-5358
  • Pérez Inestrosa, Ezequiel|||0000-0001-7546-5273
  • Collado, Daniel
  • Halir, Robert|||0000-0002-5560-3189
  • Molina-Fernandez, Iñigo|||0000-0001-9596-4117
Over the past two decades, integrated photonic sensors have been of major interest to the optical biosensor community due to their capability to detect low concentrations of molecules with label-free operation. Among these, interferometric sensors can be read-out with simple, fixed-wavelength laser sources and offer excellent detection limits but can suffer from sensitivity fading when not tuned to their quadrature point. Recently, coherently detected sensors were demonstrated as an attractive alternative to overcome this limitation. Here we show, for the first time, to the best of our knowledge, that this coherent scheme provides sub-nanogram per milliliter limits of detection in C-reactive protein immunoassays and that quasi-balanced optical arm lengths enable operation with inexpensive Fabry-Perot-type lasers sources at telecom wavelengths.