Publicación Artículo científico (JournalArticle)

Experimental approach for the uncertainty assessment of 3D complex geometry dimensional measurements using computed tomography at the mm and sub-mm scales

  • Jiménez, Roberto
  • Torralba, Marta
  • Yagüe Fabra, José Antonio
  • Ontiveros, Sinué
  • Tosello, Guido
The dimensional verification of miniaturized components with 3D complex geometries is particularly challenging. Computed Tomography (CT) can represent a suitable alternative solution to micro metrology tools based on optical and tactile techniques. However, the establishment of CT systems’ traceability when measuring 3D complex geometries is still an open issue. In this work, an alternative method for the measurement uncertainty assessment of 3D complex geometries by using CT is presented. The method is based on the micro-CT system Maximum Permissible Error (MPE) estimation, determined experimentally by using several calibrated reference artefacts. The main advantage of the presented method is that a previous calibration of the component by a more accurate Coordinate Measuring System (CMS) is not needed. In fact, such CMS would still hold all the typical limitations of optical and tactile techniques, particularly when measuring miniaturized components with complex 3D geometries and their inability to measure inner parts. To validate the presented method, the most accepted standard currently available for CT sensors, the Verein Deutscher Ingenieure/Verband Deutscher Elektrotechniker (VDI/VDE) guideline 2630-2.1 is applied. Considering the high number of influence factors in CT and their impact on the measuring result, two different techniques for surface extraction are also considered to obtain a realistic determination of the influence of data processing on uncertainty. The uncertainty assessment of a workpiece used for micro mechanical material testing is firstly used to confirm the method, due to its feasible calibration by an optical CMS. Secondly, the measurement of a miniaturized dental file with 3D complex geometry is carried out. The estimated uncertainties are eventually compared with the component’s calibration and the micro manufacturing tolerances to demonstrate the suitability of the presented CT calibration procedure. The 2U/T ratios resulting from the validation workpiece are, respectively, 0.27 (VDI) and 0.35 (MPE), by assuring tolerances in the range of +- 20–30 micro-m. For the dental file, the EN < 1 value analysis is favorable in the majority of the cases (70.4%) and 2U/T is equal to 0.31 for sub-mm measurands (L < 1 mm and tolerance intervals of +- 40–80 micro-m).
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Geometrical characterisation of a 2D laser system and calibration of a cross-grid encoder by means of a self-calibration methodology

  • Torralba, M.
  • Díaz-Pérez, L.C.
  • Valenzuela, M.
  • Albajez, J.A.
  • Yagüe-Fabra, J.A.
This article presents a self-calibration procedure and the experimental results for the geometrical characterisation of a 2D laser system operating along a large working range (50 mm × 50 mm) with submicrometre uncertainty. Its purpose is to correct the geometric errors of the 2D laser system setup generated when positioning the two laser heads and the plane mirrors used as reflectors. The non-calibrated artefact used in this procedure is a commercial grid encoder that is also a measuring instrument. Therefore, the self-calibration procedure also allows the determination of the geometrical errors of the grid encoder, including its squareness error. The precision of the proposed algorithm is tested using virtual data. Actual measurements are subsequently registered, and the algorithm is applied. Once the laser system is characterised, the error of the grid encoder is calculated along the working range, resulting in an expanded submicrometre calibration uncertainty (k = 2) for the X and Y axes. The results of the grid encoder calibration are comparable to the errors provided by the calibration certificate for its main central axes. It is, therefore, possible to confirm the suitability of the self-calibration methodology proposed in this article.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Implementation of the control strategy for a 2D nanopositioning long range stage

  • Díaz-Pérez, L.C.
  • Torralba, M.
  • Albajez, J.A.
  • Yagüe-Fabra, J.A.
A 2D-platform stage able to obtain an effective metrological positioning with nanometer resolution and long working range (50 x 50 mm2) is on development at the University of Zaragoza. The 2D stage has already been designed, manufactured and assembled. The movement of the platform is performed by four custom-made linear motors, and mirror laser interferometers work as positioning sensors in XYRz degrees of freedom. The work here presented focuses on the hardware implementation of the motor control, for one actuator on a 1D linear stage. The developed control strategy acts on three-phase PWM (Pulse-Width Modulation) signals and a feedback is provided by measuring the phase currents. As a preliminary solution, a sensorless algorithm substitutes the positioning sensor before implementing the laser interferometers.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

A surface extraction analysis in a multi-material test part for computed tomography in metrology applications

  • Jiménez-Pacheco, R.
  • Ontiveros, S.
  • Yagüe-Fabra, J.A.
The main advantage of Computed Tomography is the capability of making measurements of non-accessible internal features in a test piece. One of the cases that can usually be found in this sense is the contact zone between two elements that are forming a common surface boundary, where the main complexity is to determine which surface belongs to which piece. Nowadays, this kind of surfaces are measurable only by utilizing Computed Tomography, taking into account that the characteristics of the Tomography can significantly vary depending on the material of the elements that are in contact. In this article a piece that has two different interfaces is analyzed: a Piece in contact with Air, and Material A in contact with Material B. Three different surface extraction algorithms are analyzed for multi-material parts, Threshold, Canny and Deriche, and the results and conclusions obtained are presented.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Comparison of surface extraction techniques performance in computed tomography for 3D complex micro-geometry dimensional measurements

  • Torralba, M.
  • Jiménez, R.
  • Yagüe-Fabra, J.A.
  • Ontiveros, S.
  • Tosello, G.
The number of industrial applications of computed tomography (CT) for dimensional metrology in 100–103 mm range has been continuously increasing, especially in the last years. Due to its specific characteristics, CT has the potential to be employed as a viable solution for measuring 3D complex micro-geometries as well (i.e., in the sub-mm dimensional range). However, there are different factors that may influence the CT process performance, being one of them the surface extraction technique used. In this paper, two different extraction techniques are applied to measure a complex miniaturized dental file by CT in order to analyze its contribution to the final measurement uncertainty in complex geometries at the mm to sub-mm scales. The first method is based on a similarity analysis: the threshold determination; while the second one is based on a gradient or discontinuity analysis: the 3D Canny algorithm. This algorithm has proven to provide accurate results in parts with simple geometries, but its suitability for 3D complex geometries has not been proven so far. To verify the measurement results and compare both techniques, reference measurements are performed on an optical coordinate measuring machine (OCMM). The systematic errors and uncertainty results obtained show that the 3D Canny adapted method slightly lower systematic deviations and a more robust edge definition than the local threshold method for 3D complex micro-geometry dimensional measurements.