NUEVAS ESTRATEGIAS DE CONTROL GLUCEMICO POSTPRANDIAL MEDIANTE TERAPIA CON BOMBA DE INSULINA EN DIABETES TIPO 1

DPI2010-20764-C02-02

•
Nombre agencia financiadora Ministerio de Ciencia e Innovación
Acrónimo agencia financiadora MICINN
Programa Programa Nacional de Proyectos de Investigación Fundamental
Subprograma Subprograma de Proyectos de Investigación Fundamental no Orientada
Convocatoria Proyectos I+D
Año convocatoria 2010
Plan Estatal 2008-2011 Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica
Unidad de gestión Subdirección General de Proyectos de Investigación
Centro beneficiario UNIVERSITAT DE GIRONA
Identificador persistente http://dx.doi.org/10.13039/501100004837

Resultados relacionados

Resultados totales (Incluyendo duplicados): 11
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Real-Time Continuous Glucose Monitoring in an Intensive Care Unit: Better Accuracy in Patients with Septic Shock

  • Lorencio, Carol
  • Leal, Yenny
  • Bonet Alonso, Alfonso
  • Palerm, César C.
  • Tache, Abdo
  • Sirvent, Josep Maria
  • Vehi, Josep
  • Bondía Company, Jorge|||0000-0001-7286-3719
[EN] Objective: This study assessed the accuracy of real-time continuous glucose monitoring system (RTCGMS) devices in an intensive care unit (ICU) to determine whether the septic status of the patient has any in¿uence on the accuracy of the RTCGMS. Subjects and Methods: In total, 41 patients on insulin therapy were included. Patients were monitored for 72 h using RTCGMS. Arterial blood glucose (ABG) samples were obtained following the protocol established in the ICU. The results were evaluated using paired values (excluding those used for calibration) with the performance assessed using numerical accuracy. Nonparametric tests were used to determine statistically signi¿cant differences in accuracy. Results: In total, 956 ABG/RTCGMS pairs were analyzed. The overall median relative absolute difference (RAD) was 13.5%, and the International Organization for Standardization (ISO) criteria were 68.1%. The median RADs reported for patients with septic shock, with sepsis, and without sepsis were 11.2%, 14.3%, and 16.3%, respectively (P<0.05). Measurements meeting the ISO criteria were 74.5%, 65.6%, and 63.7% for patients with septic shock, with sepsis, and without sepsis, respectively (P<0.05). Conclusions: The results showed that the septic status of patients in¿uenced the accuracy of the RTCGMS in the ICU. Accuracy was signi¿cantly better in patients with septic shock in comparison with the other patient cohorts., This work was supported by the Spanish Ministry of Science and Innovation through grants DPI2007-66728-C02 and DPI-2010-20764-C02, the European Union through FEDER funds, and the Autonomous Government of Catalonia through 2009 SGR 523. Y.L. is grateful for the BR Grants of the University of Girona. The authors thank the Ph.D. candidate student Xavier Berjaga, who helped with the statistical analysis in this work. The authors thank the nursing staff of the ICU of Doctor Josep Trueta Hospital for their work; without them, this study could not have been conducted. Medtronic, Inc. provided some of the devices used in this study.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Prediction of postprandial blood glucose under uncertainty and intra-patient variability in type 1 diabetes: a comparative study of three interval models,

  • García Jaramillo, Maira Alejandra
  • Calm, R.
  • Vehí, J.
  • Bondía Company, Jorge|||0000-0001-7286-3719
The behavior of three insulin action and glucose kinetics models was assessed for an insulin therapy regime in the presence of patient variability. For this purpose, postprandial glucose in patients with type 1 diabetes was predicted by considering intra- and inter-patient variability using modal interval analysis. Equations to achieve optimal prediction are presented for models 1, 2 and 3, which are of increasing complexity. The model parameters were adjusted to reflect the “same” patient in the presence of variability. The glucose response envelope for model 1, the simplest insulin–glucose model assessed, included the responses of the other two models when a good fit of the model parameters was achieved. Thus, under variability, simple glucose–insulin models may be sufficient to describe patient dynamics in most situations., This work was partially supported by the Spanish Ministry of Science and Innovation through Grant DPI-2010-20764-C02, and by the Autonomous Government of Catalonia through Grant SGR 523.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Principal component analysis in combination with case-base reasoning for detecting therapeutically correct and incorrect measurements in continuous glucose monitoring

  • Leal, Yenny
  • Ruiz, Magda
  • Lorencio, Carol
  • Mujica, Luis
  • Vehi, Josep
  • Bondía Company, Jorge|||0000-0001-7286-3719
This paper introduces a data-driven methodology for detecting therapeutically correct and incorrect measurements in continuous glucose monitoring systems (CGMSs) in an intensive care unit (ICU). The data collected from 22 patients in an ICU with insulin therapy were obtained following the protocol established in the ICU. Measurements were classified using principal component analysis (PCA) in combination with case-based reasoning (CBR), where a PCA model was built to extract features that were used as inputs of the CBR system. CBR was trained to recognize patterns and classify these data. Experimental results showed that this methodology is a potential tool to distinguish between therapeutically correct and incorrect measurements from a CGMS, using the information provided by the monitor itself, and incorporating variables about the patient’s clinical condition., This work was supported by the Spanish Ministry of Science and Innovation under Grant DPI-2010-20764-C02, and by the Autonomous Government of Catalonia under Grant 2009 SGR 523. Yenny Leal is grateful for the BR Grants of the University of Girona. The authors would like to thank PhD student Xavier Berjaga, who helped with support of this work. The authors would like to thank the nursing and medical staff of the ICU of Doctor Josep Trueta Hospital for their work. They are also thankful to Medtronic, Inc., for providing some of the devices used in this study.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Detection of correct and incorrect measurements in real-time continuous glucose monitoring systems applying a postprocessing support vector machine

  • Leal, Yenny
  • GONZALEZ-ABRIL, LUIS
  • Lorencio, Carol
  • Vehí, Josep
  • Bondía Company, Jorge|||0000-0001-7286-3719
[EN] Support vector machines (SVMs) are an attractive option for detecting correct and incorrect measurements in real-time continuous glucose monitoring systems (RTCGMSs), because their learning mechanism can introduce a postprocessing strategy for imbalanced datasets. The proposed SVM considers the geometric mean to obtain a more balanced performance between sensitivity and specificity. To test this approach, 23 critically ill patients receiving insulin therapy were monitored over 72 h using an RTCGMS, and a dataset of 537 samples, classified according to International Standards Organization (ISO) criteria (372 correct and 165 incorrect measurements), was obtained. The results obtained were promising for patients with septic shock or with sepsis, for which the proposed system can be considered as reliable. However, this approach cannot be considered suitable for patients without sepsis., This work was supported by the Spanish Ministry of Science and Innovation under Grant DPI-2010-20764-C02, and by the Autonomous Government of Catalonia under Grant 2009 SGR 523. In addition, this work was partially supported by the Spanish Ministry of Economy and Competitiveness through ARTEMISA (TIN2009-14378-C02-01), and by the Andalusia Regional Ministry of Economy, Innovation and Science through Simon (TIC-8052). Y. Leal was supported by BR Grants of the University of Girona.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Identification of intra-patient variability in the postprandial response of patients with type 1 diabetes

  • Laguna Sanz, Alejandro José
  • Rossetti, Paolo
  • Ampudia Blasco, F. Javier
  • Vehí, Josep
  • Bondía Company, Jorge|||0000-0001-7286-3719
[EN] Background Identification of individualized models for patients with type 1 diabetes is of vital importance for the development of a successful artificial pancreas and other model-based strategies of insulin treatment. However, the huge intra-patient glycemic variability frequently prevents the identification of reliable models, especially in the postprandial period. In this work, the identification of postprandial models characterizing intra-patient variability is addressed. Methods Regarding the postprandial response, uncertainties due to physiological variability, input errors in insulin infusion rate and in meal content estimation are characterized by means of interval models, which predict a glucose envelope containing all possible patient responses according to the model. Multi-objective optimization is performed over a cohort of virtual patients, minimizing both the fitting error and the output glucose envelope width. A Pareto Front is then built ranging from classic identification representing average behaviors to interval identification guaranteeing full enclosure of the measurements. A method for the selection of the best individual in the Pareto Front for identification from home monitoring data with a continuous glucose monitor is presented, reducing the overestimation of patient's variability due to monitor inaccuracies and noise. Results Identification using glucose reference data provide model bands that accurately fit all data points in the used virtual data set. Identification from continuous glucose monitor data, using two different width estimation procedures yield very similar prediction capabilities of around 60% of the data points predicted, and less than a 5% average error. Conclusions In this work, a new approach to evaluate intra-patient variability in the identification of postprandial models is presented. The proposed method is feasible and shows good prediction capabilities in a 5-h time horizon as compared to reference measurements., This work received funding from the Spanish Ministry of Science and Innovation under grant DPI2010-20764-C02, from the Generalitat Valenciana under project GV/2012/085, andfromthe European UnionSeventhFramework Programme (FP7/2007-2013) under grant agreement FP7-PEOPLE-2009-IEF, Ref 252085. The authors would like to acknowledge the collaboration of Sara Correa, Geles Viguer and Pepa Gabaldón of the Diabetes Reference Unit from the Clinic University Hospital of Valencia and, in particular, all the patients for participating in the study used in this work.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Safety auxiliary feedback element for the artificial pancreas in type 1 diabetes

  • Revert Tomás, Ana
  • Garelli, Fabricio
  • Picó i Marco, Jesús
  • Battista, Hernán de
  • Rossetti, Paolo
  • Vehí, Josep
  • Bondia, Jorge
The artificial pancreas aims at the automatic delivery of insulin for glycemic control in patients with type 1 diabetes, i.e., closed-loop glucose control. One of the challenges of the artificial pancreas is to avoid controller overreaction leading to hypoglycemia, especially in the late postprandial period. In this study, an original proposal based on sliding mode reference conditioning ideas is presented as a way to reduce hypoglycemia events induced by a closed-loop glucose controller. The method is inspired in the intuitive advantages of two-step constrained control algorithms. It acts on the glucose reference sent to the main controller shaping it so as to avoid violating given constraints on the insulin-on-board. Some distinctive features of the proposed strategy are that 1) it provides a safety layer which can be adjusted according to medical criteria; 2) it can be added to closed-loop controllers of any nature; 3) it is robust against sensor failures and overestimated prandial insulin doses; and 4) it can handle nonlinear models. The method is evaluated in silico with the ten adult patients available in the FDA-accepted UVA simulator, This work was supported in part by the FEDER-CICYT under Grant DPI2008-06880-C03-01, Grant DPI2011-28112-C04-01, and Grant DPI2010-20764-C02, in part by the European Union Seventh Framework Programme (FP7/2007-2013) under Grant FP7-PEOPLE-2009-IEF Ref 252085, and in part by the Argentinian Government under Grant ANPCyT PICT-2011-0888, Grant CONICET PIP112-2011-00361, and Grant UNLP I164. The work of A. Revert was supported by the Spanish Ministry of Science and Innovation fellowship under Grant FPI BES- 2009-020327
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Robust Fault Detection System for Insulin Pump Therapy Using Continuous Glucose Monitoring

  • Herrero i Viñas, Pau
  • Calm i Puig, Remei
  • Vehí, Josep
  • Armengol Llobet, Joaquim
  • Georgiou, Pantelis
  • Oliver, Nick
  • Toumazou, Christofer
The popularity of continuous subcutaneous insulin infusion (CSII), or insulin pump therapy, as a way to deliver insulin more physiologically and achieve better glycemic control in diabetes patients has increased. Despite the substantiated therapeutic advantages of using CSII, its use has also been associated with an increased risk of technical malfunctioning of the device, which leads to an increased risk of acute metabolic complications, such as diabetic ketoacidosis. Current insulin pumps already incorporate systems to detect some types of faults, such as obstructions in the infusion set, but are not able to detect other types of fault such as the disconnection or leakage of the infusion set, This work has been funded by the Wellcome Trust, the Spanish Ministry of Science and Innovation through grant DPI2010-20764-C02, the European Union through FEDER funds and Generalitat de Catalunya under grant 2009 SGR 523
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Adaptive calibration algorithm for plasma glucose estimation in continuous glucose monitoring

  • Barceló Rico, Fátima
  • Díez Ruano, José Luís
  • Rossetti, Paolo
  • Vehí, Josep
  • Bondia, Jorge
Minimally or noninvasive continuous glucose monitors estimate plasma glucose from compartments alternative to blood, and may revolutionize the management of diabetes. However, the accuracy of current devices is still poor and it may partly depend on low performance of the implemented calibration algorithm. Here, a new adaptive calibration algorithm based on a population local-model-based intercompartmental glucose dynamic model is proposed. The novelty consists in the adaptation of data normalization parameters in real time to estimate and compensate patient's sensitivity variations. Adaptation is performed to minimize mean absolute relative deviation at the calibration points with a time window forgetting strategy. Four calibrations are used: preprandial and 1.5 h postprandial at two different meals. Two databases are used for validation: 1) a 9-h CGMS Gold (Medtronic, Northridge, USA) time series with paired reference glucose values from a clinical study in 17 subjects with type 1 diabetes; 2) data from 30 virtual patients (UVa simulator, Virginia, USA), where inter- and intrasubject variability of sensor's sensitivity were simulated. Results show how the adaptation of the normalization parameters improves the performance of the calibration algorithm since it counteracts sensor sensitivity variations. This improvement is more evident in one-week simulations, This work was supported in part by the Spanish Ministry of Science and Innovation under Project DPI2010-20764-C02 and in part by the European Union under Grant FP7-PEOPLE-2009-IEF, Ref 252085. The work of F. Barcelo-Rico was supported by the Spanish Ministry of Education (FPU AP2008-02967)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Postprandial response improvement via safety layer in closed-loop blood glucose controllers

  • León Vargas, Fabian Mauricio
  • Garelli, Fabricio
  • Battista, Hernán de
  • Vehí, Josep
Traditional type 1 diabetes therapies are prone to show poor glucose regulation especially in the postprandial period owing to both physiological and technological limitations. Although a closed-loop controller for glucose regulation has to be tuned to minimize the postprandial excursion and avoid late hypoglycemia, the intrinsic limitations of the problem lead to a trade-off between postprandial peak and late hypoglycemia risk. This paper reveals through an intensive in-silico study with multiple controller tuning combinations that a novel safety layer for glucose controllers, the so-called SAFE loop (Revert et al., 2013), not only reduces the hypoglycemia events but also allows reducing the postprandial glucose excursion, thus breaking the implicit trade-off present in single controllers. The SAFE outer loop monitors the estimated amount of insulin on board, and modifies the control action if it is close to a unique constraint which can be adjusted with clinical criteria. A very challenging test scenario is here implemented including the rate of blood glucose appearance from intakes of mixed meals, diurnal and day-to-day time-varying metabolic changes, inherent drawbacks in sensor and actuator, and other realistic conditions. The results show a significant reduction of hypoglycemia events when SAFE is added, regardless the closed-loop glucose controller, together with a potential postprandial response improvement, Research in this area is partially supported by the Spanish Ministry of Science and Innovation through grant DPI2010-20764-C02, the Government of Catalonia trough grant SGR00523, and the Argentinean Government (ANPCyT PICT-2011-0888 and 2012-0037, CONICET PIP112-2011-00361 and UNLP 1164). Fabian Leon-Vargas acknowledges the FI grants of the Government of Catalonia
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Postprandial blood glucose control using a hybrid adaptive PD controller with insulin-on-board limitation

  • León Vargas, Fabian Mauricio
  • Garelli, Fabricio
  • Battista, Hernán de
  • Vehí, Josep
This paper addresses the design of blood glucose control during the postprandial period for Type 1 diabetes patients. An artificial pancreas for ambulatory purposes has to deal with the delays inherent to the subcutaneous route, the carbohydrate intakes, the metabolic changes, the glucose sensor errors and noise, and the insulin pump constraints. A time response typically obtained in closed-loop insulin delivery shows hyperglycemia in the early postprandial period caused by the lag in the insulin absorbtion, followed by hypoglycemia caused by control over-reaction. A hybrid control system is proposed in this paper to overcome these problems. An insulin bolus is administered prior to the meals like in open-loop control, whereas a PD controller is used for robust glucose regulation. The controller gain is progressively increased after the bolus from zero up to its nominal value as function of the insulin on board, so that the PD controller becomes fully operational just when the insulin on board falls below a prescribed value. An excessive accumulation of active insulin is avoided in this way, drastically reducing the risk of hypoglycemia. The controller gain is adapted by means of a variable structure algorithm, allowing a very simple software implementation. The robust performance of the control algorithm is intensively assessed in silico on a cohort of virtual patients under challenging realistic scenarios considering mixed meals, circadian variations, time-varying uncertainties, discrete measurement and actuation, sensor errors and other disturbances, Research in this area is partially supported by the Spanish Ministry of Science and Innovation through grant DPI2010-20764-C02, the Government of Catalonia trough grant SGR00523, and the Argentinean Government (ANPCyT PICT-2011-0888, CONICET PIP112-2011-00361 and UNLP I164). Fabian León-Vargas acknowledges the FI grants of the Government of Catalonia
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Identification of intra-patient variability in the postprandial response of patients with type 1 diabetes

  • Laguna Sanz, Alejandro José
  • Rossetti, Paolo
  • Ampudia-Blasco, Francisco Javier
  • Vehí, Josep
  • Bondia, Jorge
Identification of individualized models for patients with type 1 diabetes is of vital importance for the development of a successful artificial pancreas and other model-based strategies of insulin treatment. However, the huge intra-patient glycemic variability frequently prevents the identification of reliable models, especially in the postprandial period. In this work, the identification of postprandial models characterizing intra-patient variability is addressed. Methods: Regarding the postprandial response, uncertainties due to physiological variability, input errors in insulin infusion rate and in meal content estimation are characterized by means of interval models, which predict a glucose envelope containing all possible patient responses according to the model. Multi-objective optimization is performed over a cohort of virtual patients, minimizing both the fitting error and the output glucose envelope width. A Pareto Front is then built ranging from classic identification representing average behaviors to interval identification guaranteeing full enclosure of the measurements. A method for the selection of the best individual in the Pareto Front for identification from home monitoring data with a continuous glucose monitor is presented, reducing the overestimation of patient's variability due to monitor inaccuracies and noise. Results: Identification using glucose reference data provide model bands that accurately fit all data points in the used virtual data set. Identification from continuous glucose monitor data, using two different width estimation procedures yield very similar prediction capabilities of around 60% of the data points predicted, and less than a 5% average error. Conclusions: In this work, a new approach to evaluate intra-patient variability in the identification of postprandial models is presented. The proposed method is feasible and shows good prediction capabilities in a 5-h time horizon as compared to reference measurements, This work received funding from the Spanish Ministry of Science and Innovation under grant DPI2010-20764-C02, from the Generalitat Valenciana under project GV/2012/085, and from the European Union Seventh Framework Programme (FP7/2007-2013) under grant agreement FP7-PEOPLE-2009-IEF, Ref 252085.