Pasar al contenido principal

TECNICAS DE CONTROL DE ALTAS PRESTACIONES DE MAQUINAS POLIFASICAS MEDIANTE CONVERTIDORES ELECTRONICOS DE POTENCIA Y DE SU INTERCONEXION CON LA RED ELECTRICA TRIFASICA

DPI2012-31283

•
Nombre agencia financiadora Ministerio de Economía y Competitividad
Acrónimo agencia financiadora MINECO
Programa Programa Nacional de Proyectos de Investigación Fundamental
Subprograma Subprograma de Proyectos de Investigación Fundamental no Orientada
Convocatoria Proyectos I+D
Año convocatoria 2012
Plan Estatal 2008-2011 Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica
Unidad de gestión Secretaría de Estado de Investigación, Desarrollo e Innovación
Centro beneficiario UNIVERSIDAD DE VIGO
Identificador persistente http://dx.doi.org/10.13039/501100003329

Resultados relacionados

Resultados totales (Incluyendo duplicados): 9
Encontrada(s) 1 página(s)

Investigo. Repositorio Institucional de la Universidade de Vigo
Publicación Artículo científico (JournalArticle)

Selection criteria of multiphase induction machines for speed-sensorless drives based on rotor slot harmonics

  • Gómez Yepes, Alejandro
  • Baneira Collazo, Fernando
  • Malvar Álvarez, Jano
  • Vidal González, Ana
  • Pérez Estévez, Diego
  • López Sánchez, Óscar
  • Doval Gandoy, Jesús
Multiphase (MP) induction machines (IMs) provide important advantages over three-phase (3P) ones. Sensorless speed estimation makes it possible to obtain high-performance control and monitoring without the inconveniences of speed sensors. In 3P IMs, the speed estimation methods based on rotor slot harmonics (RSHs), normally on the principal RSHs (PSHs), are well established. A difficulty of these techniques, in 3P IMs, is that RSHs are usually extremely small. Additionally, as previously assessed concerning 3P IMs, the number of rotor bars should be carefully selected; otherwise, the PSHs might not even arise in the stator current. However, no publications have addressed the magnitude of PSHs in MP IMs, in comparison to 3P ones, or selection criteria of MP IMs for speed-sensorless drives. In this paper, it is shown that in MP IMs larger (easier to detect) PSHs can be obtained, due to the low impedances in their additional stator planes, by appropriately selecting the number of bars and poles so that the PSHs are mapped into such planes. This finding is supported by newly developed stator equivalent circuits, which include the effects of rotor bars. Accordingly, criteria are presented to select MP IMs for speed-sensorless drives. Experimental and finite-element results confirm the theory., Ministerio de Economía y Competitividad | Ref. DPI2012-31283
Investigo. Repositorio Institucional de la Universidade de Vigo
Publicación Artículo científico (JournalArticle)

PLL with MAF-based prefiltering stage: small-signal modeling and performance enhancement

  • Golestan, Saeed
  • Guerrero, Josep M
  • Vidal González, Ana
  • Gómez Yepes, Alejandro
  • Doval Gandoy, Jesús
In three-phase applications, the synchronous reference frame phase-locked loop (SRF-PLL) is a standard PLL, which benefits from a simple structure and satisfactory performance under symmetrical and undistorted grid conditions. Under unbalanced and harmonically distorted conditions, however, it suffers from a very poor performance in the detection of grid voltage parameters. To deal with this challenge, incorporating different filters inside its control loop or before its input has been proposed. Recently, using the moving average filter (MAF) as the SRF-PLL prefiltering stage has been suggested in several works. The MAF is a linear-phase filter that can behave like an ideal low-pass filter under certain conditions. The main aim of this letter is to derive the small-signal model of the SRF-PLL with MAF-based prefiltering stage (briefly called the PMAF-PLL), which has not been presented before. This model enables the designer to simply analyze the stability condition and dynamic behavior of the PMAF-PLL. After developing the model, a simple yet effective modification to enhance the PMAF-PLL performance under frequency varying environments is presented. Finally, the equivalence of the PMAF-PLL and the space-vector Fourier transform-based PLL (SVFT-PLL), which is a well-known PLL in the three-phase applications, is proved. This equivalence implies that the small-signal model of the PMAF-PLL and the method presented to enhance its performance are valid for the SVFT-PLL., Ministerio de Economía y Competitividad | Ref. DPI2012-31283
Investigo. Repositorio Institucional de la Universidade de Vigo
Publicación Artículo científico (JournalArticle)

Passivity-based controller design of grid-connected VSCs for prevention of electrical resonance instability

  • Harnefors, Lennart
  • Gómez Yepes, Alejandro
  • Vidal González, Ana
  • Doval Gandoy, Jesús
The time delay in the current control loop of a grid-connected voltage-source converter (VSC) may cause destabilization of electrical resonances in the grid or in the VSC's input filter. Instability is prevented if the input admittance of the VSC can be made passive. This paper presents an analytical controller design method for obtaining passivity. The method is equally applicable to single- and three-phase systems, i.e., in the latter case, for both stationary- and synchronous-frame control. Simulations and experiments verify the theoretical results., Ministerio de Economía y Competitividad | Ref. DPI2012-31283
Investigo. Repositorio Institucional de la Universidade de Vigo
Publicación Artículo científico (JournalArticle)

Space-vector PWM with common-mode voltage elimination for multiphase drives

  • López Sánchez, Óscar
  • Álvarez Ruiz de Ojeda, Luis Jacobo
  • Malvar Álvarez, Jano
  • Gómez Yepes, Alejandro
  • Vidal González, Ana
  • Baneira Collazo, Fernando
  • Pérez Estévez, Diego
  • Freijedo Fernández, Francisco Daniel
  • Doval Gandoy, Jesús
Switching common-mode voltage (CMV) generated by the pulse width modulation (PWM) of the inverter causes common-mode currents, which lead to motor bearing failures and electromagnetic interference problems in multiphase drives. Such switching CMV can be reduced by taking advantage of the switching states of multilevel multiphase inverters that produce zero CMV. Specific space-vector PWM (SVPWM) techniques with CMV elimination, which only use zero CMV states, have been proposed for three-level five-phase drives, and for open-end winding five-, six-, and seven-phase drives, but such methods cannot be extended to a higher number of levels or phases. This paper presents a general (for any number of levels and phases) SVPMW with CMV elimination. The proposed technique can be applied to most multilevel topologies, has low computational complexity and is suitable for low-cost hardware implementations. The new algorithm is implemented in a low-cost field-programmable gate array and it is successfully tested in the laboratory using a five-level five-phase motor drive., Ministerio de Ciencia e Innovación, European Commission, Ministerio de Economía y Competitividad | Ref. DPI2012-31283, Ministerio de Economía y Competitividad | Ref. DPI2015-65419
Investigo. Repositorio Institucional de la Universidade de Vigo
Publicación Artículo científico (JournalArticle)

Estimation method of stator winding temperature for dual three-phase machines based on DC-signal injection

  • Baneira Collazo, Fernando
  • Gómez Yepes, Alejandro
  • López Sánchez, Óscar
  • Doval Gandoy, Jesús
Dual three-phase machines are becoming increasingly popular due to advantages such as inherent fault tolerant capability and lower current per phase for a given power. As in three-phase machines, it is important to provide thermal protection, in order to prevent reduction of the lifetime. Proposals specifically targeted to dual three-phase machines for estimating the stator winding temperature, and thus, avoiding the installation of thermal sensors, have not been reported so far. Concerning three-phase machines, previous publications have proposed techniques based on injecting a dc signal for estimating the stator winding temperature. However, a certain torque ripple is caused during the injection period, giving rise to a tradeoff between the magnitude of such ripple and the accuracy of the temperature estimation. This paper presents a method based on dc-signal injection for stator winding temperature estimation in dual three-phase machines with sinusoidally distributed windings and driven by field-oriented control. By applying the signal to the x-y plane, which is available in this type of machines and does not produce air-gap flux, no torque ripple is generated. Experimental results validate the proposed technique., Ministerio de Economía y Competitividad | Ref. DPI2012-31283
Investigo. Repositorio Institucional de la Universidade de Vigo
Publicación Artículo científico (JournalArticle)

Passivity-based stability assessment of grid-connected VSCs: an overview

  • Harnefors, Lennart
  • Wang, Xiongfei
  • Gómez Yepes, Alejandro
  • Blaabjerg, Frede
The interconnection stability of a grid-connected voltage-source converter (VSC) can be assessed by the passivity properties of the VSC input admittance. If critical grid resonances fall within regions where the input admittance acts passively, i.e., has nonnegative real part, then their destabilization is generally prevented. This paper presents an overview of passivity-based stability assessment, including techniques for space-vector modeling of VSCs whereby expressions for the input admittance can be derived. Design recommendations for minimizing the negative-real-part region are given as well., Ministerio de Economía y Competitividad | Ref. DPI2012-31283
Investigo. Repositorio Institucional de la Universidade de Vigo
Publicación Artículo científico (JournalArticle)

A method for identification of the equivalent inductance and resistance in the plant model of current-controlled grid-tied converters

  • Vidal González, Ana
  • Gómez Yepes, Alejandro
  • Freijedo Fernández, Francisco Daniel
  • López Sánchez, Óscar
  • Malvar Álvarez, Jano
  • Baneira Collazo, Fernando
  • Doval Gandoy, Jesús
Precise knowledge of the plant time constant L/R is essential to perform a thorough analysis and design of the current control loop in voltage source converters (VSCs). From the perspective of the current controller dynamics in the low-frequency range, such plant time constant is also suitable for most cases in which an LCL filter is used. As the loop behavior can be significantly influenced by the VSC working conditions, the effects associated to converter losses should be included in the model, through an equivalent series resistance. In addition, the plant inductance may also present important uncertainties with respect to the value of the VSC L/LCL interface filter measured at rated conditions. Thus, in this paper, a method is presented to estimate both parameters of the plant time constant, i.e., the equivalent inductance and resistance in the plant model of current-controlled VSCs. The proposed technique is based on the evaluation of the closed-loop transient responses of both axes of the synchronous reference frame when a proportional-integral current controller is implemented. The method gives a set of resistance and inductance values that should be employed for a rigorous design of the current controllers. Experimental results validate the approach., Ministerio de Economía y Competitividad | Ref. DPI2012-31283, Ministerio de Educación, Cultura y Deporte | Ref.FPU12/00117
Investigo. Repositorio Institucional de la Universidade de Vigo
Publicación Artículo científico (JournalArticle)

Tuning of synchronous-frame PI current controllers in grid-connected converters operating at a low sampling rate by MIMO root locus

  • Freijedo Fernández, Francisco Daniel
  • Vidal González, Ana
  • Gómez Yepes, Alejandro
  • Guerrero, Josep M
  • López Sánchez, Óscar
  • Malvar Álvarez, Jano
  • Doval Gandoy, Jesús
Current controller performance is key in gridconnected power converters for renewable energy applications. In this context, a challenging scenario is arising in multi-megawatt wind turbines, where sampling and switching frequencies tend to be lower and lower as power ratings increase. This strongly affects achievable control time constant. With this perspective, this paper presents a systematic procedure for accurate dynamics assessment and tuning of synchronous-frame proportional–integral current controllers, which is based on linear control for multiple-input–multiple-output (MIMO) systems. The dominant eigenvalues of the system are calculated with explicit consideration of time-delay and cross-coupling terms, two factors which clearly impair the system dynamics when considering a low sampling frequency. The proposed methodology is summarized as follows. First, the plant and controller matrices are modeled in state space. Subsequently, the characteristic polynomial of the closed-loop system is obtained and a computer-aided parametric analysis is performed to calculate the MIMO root locus as a function of the control gain. By its inspection, it is possible to identify the gain, which minimizes the current closed-loop time constant. This tuning is suitable for wind turbine applications, taking into consideration cascaded-control structures and grid-code requirements. The validity and accuracy of the analysis is fully supported by experimental verification., Energinet.dk Forskel program | Ref. PSO-2014-1-12188, Ministerio de Economía y Competitividad | Ref. DPI2012-31283
Investigo. Repositorio Institucional de la Universidade de Vigo
Publicación Artículo científico (JournalArticle)

Transient response evaluation of stationary‐frame resonant current controllers for grid‐connected applications

  • Vidal González, Ana
  • Freijedo Fernández, Francisco Daniel
  • Gómez Yepes, Alejandro
  • Malvar Álvarez, Jano
  • López Sánchez, Óscar
  • Doval Gandoy, Jesús
This study deepens on the transient response analysis of the so-called vector proportional??integral (VPI) controllers and compares them with the popular proportional??resonant (PR) controllers for grid-connected applications. The employed methodology is based on the study of the error signal roots: both reference tracking and disturbance rejection abilities are considered for proper gain tuning. This study proves that PR controllers lead to shorter settling times than VPI controllers. A three-phase voltage source converter prototype has been implemented. Experimental results comparing the transient behaviour of VPI and PR controllers in different conditions are provided: a + 90° phase-angle jump in the current reference and a 'type C' voltage sag at the point of common coupling., Ministerio de Economía y Competitividad | Ref. DPI2012-31283, Ministerio de Educación, Cultura y Deporte | Ref. FPU12/00117