Pasar al contenido principal

SISTEMAS DE PROFUNDIDAD DE FOCO EXTENDIDA Y LENTES INTRAOCULARES MULTIFOCALES PARA LA SALUD VISUAL

DPI2013-43220-R

•
Nombre agencia financiadora Ministerio de Economía y Competitividad
Acrónimo agencia financiadora MINECO
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos I+D+i Retos de Investigación
Año convocatoria 2013
Plan Estatal 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Unidad de gestión Secretaría de Estado de Educación, Formación Profesional y Universidades
Centro beneficiario UNIVERSITAT POLITECNICA DE CATALUNYA
Identificador persistente http://dx.doi.org/10.13039/501100003329

Resultados relacionados

Resultados totales (Incluyendo duplicados): 33
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Adaptive Side-by-Side Social Robot Navigation to Approach and Interact with People

  • Repiso, Ely
  • Garrell, Anaís
  • Sanfeliu, Alberto
This paper presents a new framework for how autonomous social robots approach and accompany people in urban environments. The method discussed allows the robot to accompany a person and approach to other one, by adapting its own navigation in anticipation of future interactions with other people or contact with static obstacles. The contributions of the paper are manifold: firstly, we extended the Social Force model and the Anticipative Kinodynamic Planner (Ferrer and Sanfeliu, in: IEEE/RSJ international conference on intelligent robots and systems. IEEE, 2014) to the case of an adaptive side-by-side navigation; secondly, we enhance side-by-side navigation with an approaching task and a final positioning that allows the robot to interact with both people; and finally, we use findings from experiments of real-life observations of people walking in pairs to define the parameters of the human–robot interaction in our case of adaptive side-by-side. The method was validated by a large set of simulations; we also conducted real-life experiments with our robot, Tibi, to validate the framework described for the interaction process. In addition, we carried out various surveys and user studies to indicate the social acceptability of the robots performance of the accompanying, approaching and positioning tasks., Work supported by the Spanish Ministry of Science and Innovation under project ColRobTransp (DPI2016-78957-R. AEI/FEDER EU), by the Spanish State Research Agency through the Maria de Maeztu Seal of Excellence to IRI (MDM-2016-0656) and EU TERRINET project (H2020-INFRAIA-2017-1-two-stage-730994). Ely Repiso is also supported by Spanish Ministry of Science and Innovation under a FPI-grant (BES-2014-067713)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Robot navigation to approach people using G2-spline path planning and extended social force model

  • Galván, Marta
  • Repiso, Ely
  • Sanfeliu, Alberto
Trabajo presentado en el 4th Iberian Robotics Conference, celebrado en Oporto (Portugal) en noviembre de 2019, When a robot has to interact with a person in a dynamic environment, it has to navigate to reach a close distance and to be in front of the person. This navigation has to be smooth and take care of the person's movements, the static obstacles and the motion of other people. In this paper, we present a new method to approach a person, that combines G2-Splines (G2S) paths with the Extended Social Force Model (ESFM) to allow the robot to move in dynamic environments avoiding static obstacles and other people. Moreover, we use the Bayesian human motion intentionally prediction (BMP) in combination with the Social Force Model (SFM) to be able to approach a moving person and also to avoid moving people in the environment. The method computes several paths using the G2S and taking into account the person's position and orientation. Then, the method selects the best path using several costs that consider distance, orientation, and interaction forces with static obstacles and moving people. Finally, the robot is controlled with the ESFM to follow the best path. The method was validated by a set of simulations and also by real-life experiments with a humanoid robot in a dynamic environment., Work supported by the Spanish Ministry of Science and Innovation under EU project AI4EU (H2020-ICT-2018-2-825619), the national RD project ColRobTransp (DPI2016-78957-RAEI/FEDER EU), by the Spanish State Research Agency through the Mar´ıa de Maeztu Seal of Excellence to IRI (MDM-2016-0656). Ely Repiso is also supported by Spanish Ministry of Science and Innovation under a FPI-grant, BES2014-067713.
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Roadmap on optical security

UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Cómo afectan las pantallas electrónicas al sistema visual

  • Argilés Sans, Marc|||0000-0001-5474-9832
  • Cardona Torradeflot, Genís|||0000-0002-4770-8992
  • Pérez Cabré, Elisabet|||0000-0003-4244-4235
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Visible versus near-infrared optical performance of diffractive multifocal intraocular lenses

  • Vega Lerín, Fidel|||0000-0002-8594-0872
  • Millán Garcia-Varela, M. Sagrario|||0000-0001-6950-2373
  • Vila Terricabras, Nuria
  • Alba Bueno, Francisco
© 2015 The Association for Research in Vision and Ophthalmology, Inc. PURPOSE. The purpose of this study was to compare the optical performance of diffractive multifocal intraocular lenses (DMIOLs) with visible (VIS) illumination with that of near infrared (NIR) illumination, the latter being used to test pseudophakic eyes in clinical aberrometers and double-pass systems. METHODS. Two DMIOLs of different design (Tecnis +2.75 D ZKB00 and AcrySof +2.5 D SV25T0) were tested in vitro in a model eye under both VIS (¿ 530 nm) and NIR (¿ 780 nm) illumination, and variations in the add power of the lenses were determined. Moreover, for the two wavelengths, the energy efficiency and modulation transfer function at the DMIOLs’ far and near foci were measured with pupils of 3.0 and 4.5 mm. Two counterpart monofocal IOLs (Tecnis ZA9003 and AcrySof SN60WF) were included as references in the comparison. RESULTS. With VIS light, the two DMIOLs produced relatively well-contrasted images at their near and far foci. Under NIR illumination, the add power increased, whereas the energy efficiency of the near focus decreased and that of far focus increased. Hence, the DMIOLs tended to behave like monofocal lenses because they generated good quality well-contrasted images only at their far foci. CONCLUSIONS. In addition to changes in add power, the optical performances of the DMIOLs measured under either VIS or NIR illumination are considerably different. Whereas they show two distinct (near and far) foci under VIS light, their optical performances under NIR illumination are clearly biased in favor of their far focus. These results may help prevent a misleading use of NIR-based clinical instruments for the assessment of eyes implanted with DMIOLs.
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Secure image encryption and authentication using the photon counting technique in the Gyrator domain

UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Nonlinear joint transform correlator architectures for images encryption, decryption and authentication systems

UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Halo and Through-Focus Performance of Four Diffractive Multifocal Intraocular Lenses

  • Vega Lerín, Fidel|||0000-0002-8594-0872
  • Alba Bueno, Francisco
  • Millán Garcia-Varela, M. Sagrario|||0000-0001-6950-2373
  • Varón Puentes, Maria Consuelo|||0000-0001-8923-226X
  • Gil Arnal, Miguel Ángel
  • Buil Calvo, José Antonio
PURPOSE. To compare, as a function of pupil size, the through-focus performance and halo features of four diffractive intraocular lenses (IOLs). METHODS. Three diffractive bifocal IOLs (ReSTOR þ2.5 D SV25T0, Tecnis þ2.75 D ZKB00, and AT LISA þ3.75 D 809M) and a diffractive trifocal IOL (AT LISA tri þ3.33 D, þ1.66 D 839MP) were tested in vitro in a modified International Organization for Standardization eye model. The modulation transfer function (MTF) at the IOLs’ foci was obtained with pupils ranging from 2.0 to 5.0 mm. Through-focus MTF curves (at 50 cycles/mm) were compared among all the IOLs. The halo formation and characteristics were obtained from image analysis. RESULTS. The multifocal IOLs studied in this work showed, at their foci, secondary out-of-focus images, which originate halos and whose characteristics depend on the lens design and pupil size. The smallest halo occurred for the distance focus of the SV25T0. The distance and near foci of the SV25T0 yielded, respectively, the best and lowest optical quality among the studied IOLs. The distance focus of the ZKB00, AT LISA, and AT LISA tri were of similar quality, but the near focus of the ZKB00 outperformed the near foci of the rest of the IOLs. The IOLs’ optical performance gradually deteriorates as pupil increases. CONCLUSIONS. Differences in the design of the diffractive IOLs translate into differences in optical quality at their foci, through-focus performance, and halo features, which can offer further information to surgeons when selecting which IOL to implant.
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Occlusion and noise tests on the encrypted image produced by a security system based on a joint transform correlator and the Fresnel transform

  • Vilardy Ortiz, Juan Manuel
  • Millán Garcia-Varela, M. Sagrario|||0000-0001-6950-2373
  • Pérez Cabré, Elisabet|||0000-0003-4244-4235
In this work, the occlusion and noise test on the encrypted image produced by a joint transform correlator-based encryption system in the Fresnel domain (FrD) are computed and presented, in order to check the performance of this security system with respect to the image quality resulting in the decryption process for the retrieved image. The encryption system based on a joint transform correlator (JTC) in the FrD was proposed by us, with the purpose of using a lensless optical setup. We test the performance of this security system when the encrypted image is affected by common sources of degradation such as noise (additive and multiplicative) or partial occlusion. Finally, we evaluate the performance and robustness of the security system in the FrD by using the metric of the root mean square error (RMSE) between the image to encrypt and the decrypted image when the encrypted image is degraded by noise or modified by occlusion., This research has been funded by the Universidad de La Guajira, Colombia, and the Spanish Ministerio de Ciencia e Innovación and Fondos FEDER (Project DPI2013-43220-R)., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Connectivity-based segmentation of retinal vessels in eye fundus images, Segmentación basada en la conectividad de la red vascular de la retina en imágenes de fondo de ojo

  • Rallo Capdevila, Miguel|||0000-0002-1842-5045
  • Millán Garcia-Varela, M. Sagrario|||0000-0001-6950-2373
© Sociedad Española de Óptica. A new unsupervised method for segmentation of objects of diverse nature with the common feature of connectivity (e.g. branching trees or net-shaped objects) is proposed. A preferred application to the vasculature segmentation of retinal images has been illustrated using images from DRIVE database. In the pre-processing stage, the method overcomes the common problem of non-uniform illumination of eye fundus images. The method follows with an iterative algorithm that starts with a seed and adds, at each step, a new vessel segment connected to the previously segmented part. The result preserves the connectivity as a distinct feature of the retinal vessel tree. The segmentation performance is evaluated through common signal detection metrics: sensitivity, specificity and accuracy., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Blink rate and incomplete blinks in six different controlled hard-copy and electronic reading conditions

  • Argilés Sans, Marc|||0000-0001-5474-9832
  • Cardona Torradeflot, Genís|||0000-0002-4770-8992
  • Pérez Cabré, Elisabet|||0000-0003-4244-4235
  • Rodríguez Montiel, Margarita
Purpose: to evaluate spontaneous blink rate (SEBR) and percentage of incomplete blinks in different hard-copy and visual display terminal (VDT) reading conditions, as compared with baseline conditions. Methods: A sample of 50 participants (29 females, age range 18 to 74 years) were recruited for this study. All participants had good ocular health and reported no symptoms of dry eye (OSDI score < 15). Face video recordings were captured while participants observed in silence a landscape picture at 2 meters (baseline) and during six different, 6-minute controlled reading experimental conditions. Texts were presented in electronic (tablet and computer display at 100% and 330% zoom levels) and hard-copy (text in book position in silence and aloud and text pasted on the computer display) formats. Video analysis was subsequently conducted to assess blink parameters. Results: All reading conditions resulted in a decrease in SEBR when compared with baseline conditions (all p < 0.001), with the least negative impact corresponding to reading in a 330% expanded display. The percentage of incomplete blinks was found to increase when reading was conducted on an electronic platform, in contrast to hard-copy text. Conclusions: The high cognitive demands associated with a reading task lead to a reduction in SEBR, irrespective of type of reading platform. However, only electronic reading resulted in an increase in the percentage of incomplete blinks, which may account for the symptoms experienced by VDT users.
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Effects of using an encrypted image corrupted by noise and occlusion in a security system based on joint transform correlator and Gyrator transform

UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Psychophysical Validation of a Digital Method to Assess Ill-Defined Visual Boundaries: An Example with Fabric Openness Factor

  • Tàpias Anton, Montserrat|||0000-0003-2421-0718
  • Rallo Capdevila, Miguel|||0000-0002-1842-5045
  • Escofet Soteras, Jaume|||0000-0002-1775-4779
Fabric openness factor (OF) is the fraction of the web area that is uncovered by yarns. OF is a critical feature regarding the end-use performance of the fabric and should be accurately assessed. However, digital OF estimates yielded by image binarization algorithms differ among them depending on the criteria used, mainly due to ill-defined boundaries, thus precluding a straightforward assessment of the actual fabric OF value. Lacking any standard to compare actual OF values with measured OF values, we addressed the validation procedure of the digital assessment method from visual OF estimates. OF of 81 distinct fabric samples was evaluated from digital images by a panel of 18 observers using visual binarization technique. Following the psychophysical models of Fechner and Stevens, these visual estimates were correlated with digital estimates yielded by several binarization algorithms. Stevens’ psychophysical model and an automatic binarization algorithm developed by us scored the highest correlation.
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Polychromatic image performance of diffractive bifocal intraocular lenses: longitudinal chromatic aberration and energy efficiency

  • Millán Garcia-Varela, M. Sagrario|||0000-0001-6950-2373
  • Vega Lerín, Fidel|||0000-0002-8594-0872
  • Ríos, Inmaculada
PURPOSE. The study evaluated—theoretically and experimentally—the longitudinal chromatic aberration (LCA) and through-focus energy efficiency (TF-EE) of diffractive–refractive bifocal intraocular lenses (2f-IOLs). METHODS. Four aspheric 2f-IOLs (Tecnis þ4.00 diopter [D] ZMA00, þ2.75 D ZKB00, and AcrySof þ4.0 D SN6AD3, þ2.5 D SV25T0) of same base power 30 D, but different design, additional (add) power, and different material, were tested in vitro in terms of TF-EE when illuminated by 3 red (kR ¼ 625 nm), green (kG ¼ 530 nm), and blue (kB ¼ 455 nm) lights. The LCA affecting the distance and near foci was derived theoretically and measured experimentally from the contributions of the IOLs’ refractive and diffractive powers. Longitudinal chromatic aberration was evaluated in a pseudophakic schematic eye. RESULTS. The distance focus of all 2f-IOLs showed lower energy efficiency (EE) for the blue than for the red light. AcrySof IOLs showed the largest amount of positive LCA in the distance focus that, combined with corneal LCA, would increase the resulting distance LCA in a pseudophakic eye. The near focus of all 2f-IOLs showed higher EE for the blue than for the red light. Better compensation for the LCA of a pseudophakic eye at near focus is obtained with Tecnis than with AcrySof 2f-IOLs. CONCLUSIONS. The energy distribution between the foci of diffractive 2f-IOLs depends on the lens design, the illumination wavelength, and to a lesser extent, the add power. In distance vision, 2f-IOLs’ refractive base power increases the positive LCA of prior ocular media, and the resulting LCA may even surpass the natural LCA of human eye. In near vision, however, the achromatizing effect of diffractive 2f-IOLs may compensate, in part, the natural eye’s LCA
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Nonlinear image encryption using a fully phase nonzero-order joint transform correlator in the Gyrator domain

  • Vilardy Ortiz, Juan Manuel
  • Millán Garcia-Varela, M. Sagrario|||0000-0001-6950-2373
  • Pérez Cabré, Elisabet|||0000-0003-4244-4235
© 2016 Elsevier Ltd. A novel nonlinear image encryption scheme based on a fully phase nonzero-order joint transform correlator architecture (JTC) in the Gyrator domain (GD) is proposed. In this encryption scheme, the two non-overlapping data distributions of the input plane of the JTC are fully encoded in phase and this input plane is transformed using the Gyrator transform (GT); the intensity distribution captured in the GD represents a new definition of the joint Gyrator power distribution (JGPD). The JGPD is modified by two nonlinear operations with the purpose of retrieving the encrypted image, with enhancement of the decrypted signal quality and improvement of the overall security. There are three keys used in the encryption scheme, two random phase masks and the rotation angle of the GT, which are all necessary for a proper decryption. Decryption is highly sensitivity to changes of the rotation angle of the GT as well as to little changes in other parameters or keys. The proposed encryption scheme in the GD still preserves the shift-invariance properties originated in the JTC-based encryption in the Fourier domain. The proposed encryption scheme is more resistant to brute force attacks, chosen-plaintext attacks, known-plaintext attacks, and ciphertext-only attacks, as they have been introduced in the cryptanalysis of the JTC-based encryption system. Numerical results are presented and discussed in order to verify and analyze the feasibility and validity of the novel encryption-decryption scheme.
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

First-order and multi-order diffractive lens using a device with 8P phase modulation range

UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Image quality and security through nonlinear joint transform encryption

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Comparison of visual and optical quality of monofocal versus multifocal intraocular lenses

  • Altemir-Gomez, I.
  • Millan, M.S.
  • Vega, F.
  • Bartol-Puyal, F.
  • Gimenez-Calvo, G.
  • Larrosa, J.M.
  • Polo, V.
  • Pablo, L.E.
  • Garcia-Martin, E.
Objective: To compare visual quality in patients implanted with Tecnis ® monofocal (ZCB00) and multifocal (ZMB00) intraocular lenses taking into account their optical quality measured in vitro with an eye model. Methods: In total, 122 patients participated in this study: 44 implanted with monofocal and 78 with multifocal intraocular lenses. Measurements of visual acuity and contrast sensitivity were performed. The optical quality of the intraocular lenses was evaluated in three image planes (distance, intermediate and near) using an eye model on a test bench. The metric considered was the area under the curve of the modulation transfer function. Results: Optical quality at the far focus of the monofocal intraocular lens (area under the curve of the modulation transfer function = 66.97) was considerably better than that with the multifocal lens (area under the curve of the modulation transfer function = 32.54). However, no significant differences were observed between groups at the distance-corrected visual acuity. Distance-corrected near vision was better in the multifocal (0.15 ± 0.20 logMAR) than that in the monofocal group (0.43 ± 0.21 logMAR, p < 0.001), which correlated with the better optical quality at near reached by the multifocal intraocular lens (area under the curve of the modulation transfer function = 29.11) in comparison with the monofocal intraocular lens (area under the curve of the modulation transfer function = 5.0). In intermediate vision, visual acuity was 0.28 ± 0.16 logMAR (multifocal) and 0.36 ± 0.14 logMAR (monofocal) with p = 0.014, also in good agreement with the values measured in the optical quality (area under the curve of the modulation transfer function = 10.69 (multifocal) and 8.86 (monofocal)). The contrast sensitivity was similar in almost all frequencies. Pelli–Robson was slightly better in the monofocal (1.73) than in the multifocal group (1.64; p = 0.023). Conclusion: Patients implanted with multifocal ZMB00 achieved a distance visual acuity similar to those implanted with monofocal ZCB00, but showed significantly better intermediate and near visual acuity. A correlation was found between intraocular lenses’ optical quality and patients’ visual acuity. Contrast sensitivity was very similar between the multifocal and monofocal groups.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Polychromatic image performance of diffractive bifocal intraocular lenses: longitudinal chromatic aberration and energy efficiency

  • Millán Garcia-Varela, M. Sagrario
  • Vega Lerín, Fidel
  • Ríos, Inmaculada
PURPOSE. The study evaluated—theoretically and experimentally—the longitudinal chromatic aberration (LCA) and through-focus energy efficiency (TF-EE) of diffractive–refractive bifocal intraocular lenses (2f-IOLs). METHODS. Four aspheric 2f-IOLs (Tecnis þ4.00 diopter [D] ZMA00, þ2.75 D ZKB00, and AcrySof þ4.0 D SN6AD3, þ2.5 D SV25T0) of same base power 30 D, but different design, additional (add) power, and different material, were tested in vitro in terms of TF-EE when illuminated by 3 red (kR ¼ 625 nm), green (kG ¼ 530 nm), and blue (kB ¼ 455 nm) lights. The LCA affecting the distance and near foci was derived theoretically and measured experimentally from the contributions of the IOLs’ refractive and diffractive powers. Longitudinal chromatic aberration was evaluated in a pseudophakic schematic eye. RESULTS. The distance focus of all 2f-IOLs showed lower energy efficiency (EE) for the blue than for the red light. AcrySof IOLs showed the largest amount of positive LCA in the distance focus that, combined with corneal LCA, would increase the resulting distance LCA in a pseudophakic eye. The near focus of all 2f-IOLs showed higher EE for the blue than for the red light. Better compensation for the LCA of a pseudophakic eye at near focus is obtained with Tecnis than with AcrySof 2f-IOLs. CONCLUSIONS. The energy distribution between the foci of diffractive 2f-IOLs depends on the lens design, the illumination wavelength, and to a lesser extent, the add power. In distance vision, 2f-IOLs’ refractive base power increases the positive LCA of prior ocular media, and the resulting LCA may even surpass the natural LCA of human eye. In near vision, however, the achromatizing effect of diffractive 2f-IOLs may compensate, in part, the natural eye’s LCA, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Image quality and security through nonlinear joint transform encryption

Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Visible versus near-infrared optical performance of diffractive multifocal intraocular lenses

  • Vega Lerín, Fidel
  • Millán Garcia-Varela, M. Sagrario
  • Vila Terricabras, Nuria
  • Alba Bueno, Francisco
© 2015 The Association for Research in Vision and Ophthalmology, Inc. PURPOSE. The purpose of this study was to compare the optical performance of diffractive multifocal intraocular lenses (DMIOLs) with visible (VIS) illumination with that of near infrared (NIR) illumination, the latter being used to test pseudophakic eyes in clinical aberrometers and double-pass systems. METHODS. Two DMIOLs of different design (Tecnis +2.75 D ZKB00 and AcrySof +2.5 D SV25T0) were tested in vitro in a model eye under both VIS (¿ 530 nm) and NIR (¿ 780 nm) illumination, and variations in the add power of the lenses were determined. Moreover, for the two wavelengths, the energy efficiency and modulation transfer function at the DMIOLs’ far and near foci were measured with pupils of 3.0 and 4.5 mm. Two counterpart monofocal IOLs (Tecnis ZA9003 and AcrySof SN60WF) were included as references in the comparison. RESULTS. With VIS light, the two DMIOLs produced relatively well-contrasted images at their near and far foci. Under NIR illumination, the add power increased, whereas the energy efficiency of the near focus decreased and that of far focus increased. Hence, the DMIOLs tended to behave like monofocal lenses because they generated good quality well-contrasted images only at their far foci. CONCLUSIONS. In addition to changes in add power, the optical performances of the DMIOLs measured under either VIS or NIR illumination are considerably different. Whereas they show two distinct (near and far) foci under VIS light, their optical performances under NIR illumination are clearly biased in favor of their far focus. These results may help prevent a misleading use of NIR-based clinical instruments for the assessment of eyes implanted with DMIOLs., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Connectivity-based segmentation of retinal vessels in eye fundus images, Segmentación basada en la conectividad de la red vascular de la retina en imágenes de fondo de ojo

  • Rallo Capdevila, Miguel
  • Millán Garcia-Varela, M. Sagrario
© Sociedad Española de Óptica. A new unsupervised method for segmentation of objects of diverse nature with the common feature of connectivity (e.g. branching trees or net-shaped objects) is proposed. A preferred application to the vasculature segmentation of retinal images has been illustrated using images from DRIVE database. In the pre-processing stage, the method overcomes the common problem of non-uniform illumination of eye fundus images. The method follows with an iterative algorithm that starts with a seed and adds, at each step, a new vessel segment connected to the previously segmented part. The result preserves the connectivity as a distinct feature of the retinal vessel tree. The segmentation performance is evaluated through common signal detection metrics: sensitivity, specificity and accuracy., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

First-order and multi-order diffractive lens using a device with 8P phase modulation range

Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Roadmap on optical security

Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Blink rate and incomplete blinks in six different controlled hard-copy and electronic reading conditions

  • Argilés Sans, Marc
  • Cardona Torradeflot, Genís
  • Pérez Cabré, Elisabet
  • Rodríguez Montiel, Margarita
Purpose: to evaluate spontaneous blink rate (SEBR) and percentage of incomplete blinks in different hard-copy and visual display terminal (VDT) reading conditions, as compared with baseline conditions. Methods: A sample of 50 participants (29 females, age range 18 to 74 years) were recruited for this study. All participants had good ocular health and reported no symptoms of dry eye (OSDI score < 15). Face video recordings were captured while participants observed in silence a landscape picture at 2 meters (baseline) and during six different, 6-minute controlled reading experimental conditions. Texts were presented in electronic (tablet and computer display at 100% and 330% zoom levels) and hard-copy (text in book position in silence and aloud and text pasted on the computer display) formats. Video analysis was subsequently conducted to assess blink parameters. Results: All reading conditions resulted in a decrease in SEBR when compared with baseline conditions (all p < 0.001), with the least negative impact corresponding to reading in a 330% expanded display. The percentage of incomplete blinks was found to increase when reading was conducted on an electronic platform, in contrast to hard-copy text. Conclusions: The high cognitive demands associated with a reading task lead to a reduction in SEBR, irrespective of type of reading platform. However, only electronic reading resulted in an increase in the percentage of incomplete blinks, which may account for the symptoms experienced by VDT users., Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Occlusion and noise tests on the encrypted image produced by a security system based on a joint transform correlator and the Fresnel transform

  • Vilardy Ortiz, Juan Manuel
  • Millán Garcia-Varela, M. Sagrario
  • Pérez Cabré, Elisabet
In this work, the occlusion and noise test on the encrypted image produced by a joint transform correlator-based encryption system in the Fresnel domain (FrD) are computed and presented, in order to check the performance of this security system with respect to the image quality resulting in the decryption process for the retrieved image. The encryption system based on a joint transform correlator (JTC) in the FrD was proposed by us, with the purpose of using a lensless optical setup. We test the performance of this security system when the encrypted image is affected by common sources of degradation such as noise (additive and multiplicative) or partial occlusion. Finally, we evaluate the performance and robustness of the security system in the FrD by using the metric of the root mean square error (RMSE) between the image to encrypt and the decrypted image when the encrypted image is degraded by noise or modified by occlusion., This research has been funded by the Universidad de La Guajira, Colombia, and the Spanish Ministerio de Ciencia e Innovación and Fondos FEDER (Project DPI2013-43220-R)., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Halo and Through-Focus Performance of Four Diffractive Multifocal Intraocular Lenses

  • Vega Lerín, Fidel
  • Alba Bueno, Francisco
  • Millán Garcia-Varela, M. Sagrario
  • Varón Puentes, Maria Consuelo
  • Gil Arnal, Miguel Ángel
  • Buil Calvo, José Antonio
PURPOSE. To compare, as a function of pupil size, the through-focus performance and halo features of four diffractive intraocular lenses (IOLs). METHODS. Three diffractive bifocal IOLs (ReSTOR þ2.5 D SV25T0, Tecnis þ2.75 D ZKB00, and AT LISA þ3.75 D 809M) and a diffractive trifocal IOL (AT LISA tri þ3.33 D, þ1.66 D 839MP) were tested in vitro in a modified International Organization for Standardization eye model. The modulation transfer function (MTF) at the IOLs’ foci was obtained with pupils ranging from 2.0 to 5.0 mm. Through-focus MTF curves (at 50 cycles/mm) were compared among all the IOLs. The halo formation and characteristics were obtained from image analysis. RESULTS. The multifocal IOLs studied in this work showed, at their foci, secondary out-of-focus images, which originate halos and whose characteristics depend on the lens design and pupil size. The smallest halo occurred for the distance focus of the SV25T0. The distance and near foci of the SV25T0 yielded, respectively, the best and lowest optical quality among the studied IOLs. The distance focus of the ZKB00, AT LISA, and AT LISA tri were of similar quality, but the near focus of the ZKB00 outperformed the near foci of the rest of the IOLs. The IOLs’ optical performance gradually deteriorates as pupil increases. CONCLUSIONS. Differences in the design of the diffractive IOLs translate into differences in optical quality at their foci, through-focus performance, and halo features, which can offer further information to surgeons when selecting which IOL to implant., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Nonlinear image encryption using a fully phase nonzero-order joint transform correlator in the Gyrator domain

  • Vilardy Ortiz, Juan Manuel
  • Millán Garcia-Varela, M. Sagrario
  • Pérez Cabré, Elisabet
© 2016 Elsevier Ltd. A novel nonlinear image encryption scheme based on a fully phase nonzero-order joint transform correlator architecture (JTC) in the Gyrator domain (GD) is proposed. In this encryption scheme, the two non-overlapping data distributions of the input plane of the JTC are fully encoded in phase and this input plane is transformed using the Gyrator transform (GT); the intensity distribution captured in the GD represents a new definition of the joint Gyrator power distribution (JGPD). The JGPD is modified by two nonlinear operations with the purpose of retrieving the encrypted image, with enhancement of the decrypted signal quality and improvement of the overall security. There are three keys used in the encryption scheme, two random phase masks and the rotation angle of the GT, which are all necessary for a proper decryption. Decryption is highly sensitivity to changes of the rotation angle of the GT as well as to little changes in other parameters or keys. The proposed encryption scheme in the GD still preserves the shift-invariance properties originated in the JTC-based encryption in the Fourier domain. The proposed encryption scheme is more resistant to brute force attacks, chosen-plaintext attacks, known-plaintext attacks, and ciphertext-only attacks, as they have been introduced in the cryptanalysis of the JTC-based encryption system. Numerical results are presented and discussed in order to verify and analyze the feasibility and validity of the novel encryption-decryption scheme., Preprint
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Nonlinear joint transform correlator architectures for images encryption, decryption and authentication systems

Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Effects of using an encrypted image corrupted by noise and occlusion in a security system based on joint transform correlator and Gyrator transform

Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Secure image encryption and authentication using the photon counting technique in the Gyrator domain

Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Cómo afectan las pantallas electrónicas al sistema visual

Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Psychophysical Validation of a Digital Method to Assess Ill-Defined Visual Boundaries: An Example with Fabric Openness Factor

  • Tàpias Anton, Montserrat
  • Rallo Capdevila, Miguel
  • Escofet Soteras, Jaume
Fabric openness factor (OF) is the fraction of the web area that is uncovered by yarns. OF is a critical feature regarding the end-use performance of the fabric and should be accurately assessed. However, digital OF estimates yielded by image binarization algorithms differ among them depending on the criteria used, mainly due to ill-defined boundaries, thus precluding a straightforward assessment of the actual fabric OF value. Lacking any standard to compare actual OF values with measured OF values, we addressed the validation procedure of the digital assessment method from visual OF estimates. OF of 81 distinct fabric samples was evaluated from digital images by a panel of 18 observers using visual binarization technique. Following the psychophysical models of Fechner and Stevens, these visual estimates were correlated with digital estimates yielded by several binarization algorithms. Stevens’ psychophysical model and an automatic binarization algorithm developed by us scored the highest correlation., Preprint