Pasar al contenido principal

DOSIMETRIA MEDIANTE DIODOS DE SILICIO 3D

DPI2014-57645-R

•
Nombre agencia financiadora Ministerio de Economía y Competitividad
Acrónimo agencia financiadora MINECO
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos I+D+i Retos de Investigación
Año convocatoria 2014
Plan Estatal 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Unidad de gestión Secretaría de Estado de Educación, Formación Profesional y Universidades
Centro beneficiario UNIVERSIDADE DE SANTIAGO DE COMPOSTELA
Identificador persistente http://dx.doi.org/10.13039/501100003329

Resultados relacionados

Resultados totales (Incluyendo duplicados): 1
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Microdosimetric Spectra Measurements on a Clinical Carbon Beam at Nominal Therapeutic Fluence Rate With Silicon Cylindrical Microdosimeters

  • Prieto-Pena, Juan
  • Gomez, Faustino
  • Fleta, Celeste
  • Guardiola, Consuelo
  • Pellegrini, Giulio
  • Donetti, Marco
  • Giordanengo, Simona
  • Gonzalez-Castano, Diego M.
  • Pardo-Montero, Juan
The use of protons and heavy ions for the treatment of tumors is increasing since it provides a better relative biological effectiveness (RBE) than traditional radiotherapy. Accurate knowledge of the energy deposition at submicrometric scales is paramount for RBE characterization. This paper shows the latest version of the silicon cylindrical microdosimeter array developed by the Instituto de Microelectrónica de Barcelona, Centro Nacional de Microelectrónica (IMB-CNM, Spain). The detector consists of a matrix of 11 × 11 cylindrical sensitive unit cells with individual readout etched within the silicon substrate available in different diameters and pitches between detectors. The detector employed in this paper had a diameter of 15μ, a pitch of 200μ, and a thickness of 5.5μ. The detectors were tested in the clinical facilities of Fondazione Centro Nazionale di Adronterapia Oncologica (CNAO) (Pavia, Italy) employing a 12C pencil beam at a therapeutic beam fluence rate. Microdosimetric spectra of lineal energy were measured in different depths of polymethyl methacrylate (PMMA) up to the Bragg peak. Results were then compared with Monte Carlo simulations using the FLUKA particle transport code, showing an excellent agreement between experimental and simulated microdosimetric distributions even at the high fluence rates associated with clinical beams., Manuscript received May 7, 2019; accepted June 4, 2019. Date of publication June 6, 2019; date of current version July 16, 2019. The works of J. Prieto-Pena, F. Gómez, and D. M. González-Castaño were supported by the Spanish MINECO Project under Grant DPI2014-57645-R. The work of J. Prieto-Pena was supported by a Predoctoral Fundación Barrié Grant. The work of J. Pardo-Montero was supported by the Instituto de Salud Carlos III under Grant CPII17/00028, Grant PI17/01428, and Grant DTS17/00123., Peer reviewed