BIOMARCADORES FISIOLOGICOS MULTIMODALES PARA LA MONITORIZACION NO-INVASIVA Y CUIDADO A DOMICILIO DE PACIENTES EPOC CON COMORBILIDADES

DPI2015-68820-R

•
Nombre agencia financiadora Ministerio de Economía y Competitividad
Acrónimo agencia financiadora MINECO
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos I+D+i Retos de Investigación
Año convocatoria 2015
Plan Estatal 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Unidad de gestión Dirección General de Investigación Científica y Técnica
Centro beneficiario FUNDACIO INSTITUT DE BIOENGINYERIA DE CATALUNYA
Identificador persistente http://dx.doi.org/10.13039/501100003329

Resultados relacionados

Resultados totales (Incluyendo duplicados): 17
Encontrada(s) 1 página(s)

Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Inspiratory muscle activation increases with COPD severity as confirmed by non-invasive mechanomyographic analysis

  • Sarlabous, Leonardo
  • Torres, Abel
  • Fiz, José Antonio
  • Martínez-Llorens, Juana Mª
  • Gea Guiral, Joaquim
  • Jané, Raimon
There is a lack of instruments for assessing respiratory muscle activation during the breathing cycle in clinical conditions. The aim of the present study was to evaluate the usefulness of the respiratory muscle mechanomyogram (MMG) for non-invasively assessing the mechanical activation of the inspiratory muscles of the lower chest wall in both patients with chronic obstructive pulmonary disease (COPD) and healthy subjects, and to investigate the relationship between inspiratory muscle activation and pulmonary function parameters. Both inspiratory mouth pressure and respiratory muscle MMG were simultaneously recorded under two different respiratory conditions, quiet breathing and incremental ventilatory effort, in 13 COPD patients and 7 healthy subjects. The mechanical activation of the inspiratory muscles was characterised by the non-linear multistate Lempel-Ziv index (MLZ) calculated over the inspiratory time of the MMG signal. Subsequently, the efficiency of the inspiratory muscle mechanical activation was expressed as the ratio between the peak inspiratory mouth pressure to the amplitude of the mechanical activation. This activation estimated using the MLZ index correlated strongly with peak inspiratory mouth pressure throughout the respiratory protocol in both COPD patients (r = 0.80, p<0.001) and healthy (r = 0.82, p<0.001). Moreover, the greater the COPD severity in patients, the greater the level of muscle activation (r = -0.68, p = 0.001, between muscle activation at incremental ventilator effort and FEV1). Furthermore, the efficiency of the mechanical activation of inspiratory muscle was lower in COPD patients than healthy subjects (7.61±2.06 vs 20.42±10.81, respectively, p = 0.0002), and decreased with increasing COPD severity (r = 0.78, p<0.001, between efficiency of the mechanical activation at incremental ventilatory effort and FEV1). These results suggest that the respiratory muscle mechanomyogram is a good reflection of inspiratory effort and can be used to estimate the efficiency of the mechanical activation of the inspiratory muscles. Both, inspiratory muscle activation and inspiratory muscle mechanical activation efficiency are strongly correlated with the pulmonary function. Therefore, the use of the respiratory muscle mechanomyogram can improve the assessment of inspiratory muscle activation in clinical conditions, contributing to a better understanding of breathing in COPD patients., This work was supported in part by the Secretariat of Universities and Research of the Ministry of Economy and Knowledge of the Generalitat de Catalunya (consolidated research groups GRC 2014 SGR 1569 and 424, and CERCA Programme), the Plan Nacional (SAF2014-54371), and by the Ministry of Economy and Competitiveness of the Spanish Government and the European Regional Development Fund, DPI2015-68820-R (MINECO/FEDER).
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Sleep stage influence on the autonomic modulation of sleep apnea syndrome

  • Calvo González, Mireia
  • Jané Campos, Raimon|||0000-0002-6541-8729
© 2019 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting /republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works, Hypoxia induced by obstructive sleep apnea (OSA) leads to the deregulation of the autonomic nervous system (ANS), resulting in an abnormally increased sympathetic activity. Since ANS modulation varies throughout the night, notably for each sleep stage, the hypno-gram and heart rate signals of 81 OSA patients were collected during a polysomnography. They were classified as mild-moderate (n=44) or severe (n=37) based on their apnea-hypopnea index (AHI). Spectral heart rate variability (HRV) series were extracted by a time-frequency approach. These series were then averaged for each sleep stage, in order to compare the sympathetic modulation of mild-moderate and severe patients at the following phases: rapid eye movement (REM), S1, S2 and SWS (slow wave sleep). According to normalized power at the low-frequency band (LF nu ) values, severe OSA seems to be associated with an increased sympathetic modulation at non-REM sleep. Moreover, a decreased autonomic variability throughout the night may be related to a reduced adaptability of the cardiovascular system, characterizing a more advanced stage of the disease. These results provide further evidence for the role of autonomic alterations induced by hypoxia, suggesting the use of HRV analysis, together with AHI, for the study of OSA severity, Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Chest movement and respiratory volume both contribute to thoracic bioimpedance during loaded breathing

  • Blanco Almazán, María Dolores|||0000-0002-8532-5394
  • Groenendaal, Willemijn
  • Catthoor, Francky
  • Jané Campos, Raimon|||0000-0002-6541-8729
Bioimpedance has been widely studied as alternative to respiratory monitoring methods because of its linear relationship with respiratory volume during normal breathing. However, other body tissues and fluids contribute to the bioimpedance measurement. The objective of this study is to investigate the relevance of chest movement in thoracic bioimpedance contributions to evaluate the applicability of bioimpedance for respiratory monitoring. We measured airflow, bioimpedance at four electrode configurations and thoracic accelerometer data in 10 healthy subjects during inspiratory loading. This protocol permitted us to study the contributions during different levels of inspiratory muscle activity. We used chest movement and volume signals to characterize the bioimpedance signal using linear mixed-effect models and neural networks for each subject and level of muscle activity. The performance was evaluated using the Mean Average Percentage Errors for each respiratory cycle. The lowest errors corresponded to the combination of chest movement and volume for both linear models and neural networks. Particularly, neural networks presented lower errors (median below 4.29%). At high levels of muscle activity, the differences in model performance indicated an increased contribution of chest movement to the bioimpedance signal. Accordingly, chest movement contributed substantially to bioimpedance measurement and more notably at high muscle activity levels., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Non-linear HRV analysis to quantify the effects of intermittent hypoxia using an OSA rat model

  • Romero, Daniel
  • Jané Campos, Raimon|||0000-0002-6541-8729
© 2019 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting /republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works, In this paper, a non-linear HRV analysis was performed to assess fragmentation signatures observed in heartbeat time series after intermittent hypoxia (IH). Three markers quantifying short-term fragmentation levels, PIP, IALS and PSS, were evaluated on R-R interval series obtained in a rat model of recurrent apnea. Through airway obstructions, apnea episodes were periodically simulated in six anesthetized Sprague-Dawley rats. The number of apnea events per hour (AHI index) was varied during the first half of the experiment while apnea episodes lasted 15 s. For the second part, apnea episodes lasted 5, 10 or 15 s, but the AHI index was fixed. Recurrent apnea was repeated for 15-min time intervals in all cases, alternating with basal periods of the same duration. The fragmentation markers were evaluated in segments of 5 minutes, selected at the beginning and end of the experiment. The impact of the heart and breathing rates (HR and BR, respectively) on the parameter estimates was also investigated. The results obtained show a significant increase (from 5 to 10%, p <; 0.05) in fragmentation measures of heartbeat time series after IH, indicating a clear deterioration of the initial conditions. Moreover, there was a strong linear relationship (r > 0.9) between these markers and BR, as well as with the ratio given by HR/BR. Although fragmentation may be impacted by IH, we found that it is highly dependent on HR and BR values and thus, they should be considered during its calculation or used to normalize the fragmentation estimates, Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Analysis of time delay between bioimpedance and respiratory volume signals under inspiratory loaded breathing

  • Blanco Almazán, María Dolores|||0000-0002-8532-5394
  • Groenendaal, Willemijn
  • Catthoor, Francky
  • Jané Campos, Raimon|||0000-0002-6541-8729
© 2019 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting /republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works, Bioimpedance is known for its linear relation with volume during normal breathing. For that reason, bioimpedance can be used as a noninvasive and comfortable technique for measuring respiration. The goal of this study is to analyze the temporal behavior of bioimpedance measured in four different electrode configurations during inspiratory loaded breathing. We measured four bioimpedance channels and airflow simultaneously in 10 healthy subjects while incremental inspiratory loads were imposed. Inspiratory loading threshold protocols are associated with breathing pattern changes and were used in respiratory mechanics studies. Consequently, this respiratory protocol allowed us to induce breathing pattern changes and evaluate the temporal relationship of bioimpedance with volume. We estimated the temporal delay between bioimpedance and volume respiratory cycles to evaluate the differences in their temporal behavior. The delays were computed as the lag which maximize the cross-correlation of the signals cycle by cycle. Six of the ten subjects showed delays in at least two different inspiratory loads. The delays were dependent on electrode configuration, hence the appearance of the delays between bioimpedance and volume were conditioned to the location and geometry of the electrode configuration. In conclusion, the delays between these signals could provide information about breathing pattern when breathing conditions change, Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Study of time-frequency characteristics of single snores: extracting new information for sleep apnea diagnosis

  • Castillo Escario, Yolanda|||0000-0002-7493-1268
  • Blanco Almazán, Dolores
  • Cámara, Miguel Ángel
  • Jané Campos, Raimon|||0000-0002-6541-8729
Obs tructive sleep apnea (OSA) is a highly prevalent chronic disease, especially in elderly and obese population . Despite constitut ing a huge health and economic problem, most patients remain undiagnosed due to limitations in current strategies. Therefore, it is essential to find cost - effective diagnostic alternatives. One of these novel approaches is the analysis of acoustic snoring signals. Snoring is an early symptom of OSA which carr ies pathophysiological information of high diagnostic value. For this reason, the main objective of this work is to study the characteristics of single snores of different types, from healthy and OSA subjects. To do that, we analyzed snoring signals from p revious databases and developed an experimental protocol to record simulated OSA - related sounds and characterize the response of two commercial tracheal microphones. Automatic programs for filtering, downsampling, event detection and time - frequency analysi s were built in MATLAB. We found that time - frequency maps and spectral parameters (central, mean and peak frequency and energy in the 100 - 500 Hz band) allow distinguishing regular snores of healthy subjects from non - regular snores and snores of OSA subject s. Regarding the two commercial microphones, we f ound that one of them was a suitable snoring sensor, while the other had a too restricted frequency response. Future work shall include a higher number of episode s and subjects , but our study has contributed to show how important the differences between regular and non - regular snores can be for OSA diagnosis, and how much clinically relevant information can be extracted from time - frequency maps and spectral parameters of single snores, Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Wearable bioimpedance measurement for respiratory monitoring during inspiratory loading

  • Blanco Almazán, María Dolores|||0000-0002-8532-5394
  • Groenendaal, Willemijn
  • Catthoor, Francky
  • Jané Campos, Raimon|||0000-0002-6541-8729
Bioimpedance is an unobtrusive noninvasive technique to measure respiration and has a linear relation with volume during normal breathing. The objective of this paper was to assess this linear relation during inspiratory loading protocol and determine the best electrode configuration for bioimpedance measurement. The inspiratory load is a way to estimate inspiratory muscle function and has been widely used in studies of respiratory mechanics. Therefore, this protocol permitted us to evaluate bioimpedance performance under breathing pattern changes. We measured four electrode configurations of bioimpedance and airflow simultaneously in ten healthy subjects using a wearable device and a standard wired laboratory acquisition system, respectively. The subjects were asked to perform an incremental inspiratory threshold loading protocol during the measurements. The load values were selected to increase progressively until the 60% of the subject's maximal inspiratory pressure. The linear relation of the signals was assessed by Pearson correlation (r) and the waveform agreement by the mean absolute percentage error (MAPE), both computed cycle by cycle. The results showed a median greater than 0.965 in r coefficients and lower than 11 % in the MAPE values for the entire population in all loads and configurations. Thus, a strong linear relation was found during all loaded breathing and configurations. However, one out of the four electrode configurations showed robust results in terms of agreement with volume during the highest load. In conclusion, bioimpedance measurement using a wearable device is a noninvasive and a comfortable alternative to classical methods for monitoring respiratory diseases in normal and restrictive breathing.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Eigenvalue-based time delay estimation of repetitive biomedical signals

  • Laguna, P.
  • Garde, A.
  • Giraldo, B.F.
  • Meste, O.
  • Jané, R.
  • Sörnmo, L.
The time delay estimation problem associated with an ensemble of misaligned, repetitive signals is revisited. Each observed signal is assumed to be composed of an unknown, deterministic signal corrupted by Gaussian, white noise. This paper shows that maximum likelihood (ML) time delay estimation can be viewed as the maximization of an eigenvalue ratio, where the eigenvalues are obtained from the ensemble correlation matrix. A suboptimal, one-step time delay estimate is proposed for initialization of the ML estimator, based on one of the eigenvectors of the inter-signal correlation matrix. With this approach, the ML estimates can be determined without the need for an intermediate estimate of the underlying, unknown signal. Based on respiratory flow signals, simulations show that the variance of the time delay estimation error for the eigenvalue-based method is almost the same as that of the ML estimator. Initializing the maximization with the one-step estimates, rather than using the ML estimator alone, the computation time is reduced by a factor of 5M when using brute force maximization (M denoting the number of signals in the ensemble), and a factor of about 1.5 when using particle swarm maximization. It is concluded that eigenanalysis of the ensemble correlation matrix not only provides valuable insight on how signal energy, jitter, and noise influence the estimation process, but it also leads to a one-step estimator which can make the way for a substantial reduction in computation time.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Sleep stage influence on the autonomic modulation of sleep apnea syndrome

  • Calvo González, Mireia
  • Jané Campos, Raimon
© 2019 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting /republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works, Hypoxia induced by obstructive sleep apnea (OSA) leads to the deregulation of the autonomic nervous system (ANS), resulting in an abnormally increased sympathetic activity. Since ANS modulation varies throughout the night, notably for each sleep stage, the hypno-gram and heart rate signals of 81 OSA patients were collected during a polysomnography. They were classified as mild-moderate (n=44) or severe (n=37) based on their apnea-hypopnea index (AHI). Spectral heart rate variability (HRV) series were extracted by a time-frequency approach. These series were then averaged for each sleep stage, in order to compare the sympathetic modulation of mild-moderate and severe patients at the following phases: rapid eye movement (REM), S1, S2 and SWS (slow wave sleep). According to normalized power at the low-frequency band (LF nu ) values, severe OSA seems to be associated with an increased sympathetic modulation at non-REM sleep. Moreover, a decreased autonomic variability throughout the night may be related to a reduced adaptability of the cardiovascular system, characterizing a more advanced stage of the disease. These results provide further evidence for the role of autonomic alterations induced by hypoxia, suggesting the use of HRV analysis, together with AHI, for the study of OSA severity, Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Inspiratory muscle activation increases with COPD severity as confirmed by non-invasive mechanomyographic analysis

  • Sarlabous, Leonardo
  • Torres, Abel
  • Fiz, José Antonio
  • Martínez-Llorens, Juana Mª
  • Gea Guiral, Joaquim
  • Jané, Raimon
There is a lack of instruments for assessing respiratory muscle activation during the breathing cycle in clinical conditions. The aim of the present study was to evaluate the usefulness of the respiratory muscle mechanomyogram (MMG) for non-invasively assessing the mechanical activation of the inspiratory muscles of the lower chest wall in both patients with chronic obstructive pulmonary disease (COPD) and healthy subjects, and to investigate the relationship between inspiratory muscle activation and pulmonary function parameters. Both inspiratory mouth pressure and respiratory muscle MMG were simultaneously recorded under two different respiratory conditions, quiet breathing and incremental ventilatory effort, in 13 COPD patients and 7 healthy subjects. The mechanical activation of the inspiratory muscles was characterised by the non-linear multistate Lempel-Ziv index (MLZ) calculated over the inspiratory time of the MMG signal. Subsequently, the efficiency of the inspiratory muscle mechanical activation was expressed as the ratio between the peak inspiratory mouth pressure to the amplitude of the mechanical activation. This activation estimated using the MLZ index correlated strongly with peak inspiratory mouth pressure throughout the respiratory protocol in both COPD patients (r = 0.80, p<0.001) and healthy (r = 0.82, p<0.001). Moreover, the greater the COPD severity in patients, the greater the level of muscle activation (r = -0.68, p = 0.001, between muscle activation at incremental ventilator effort and FEV1). Furthermore, the efficiency of the mechanical activation of inspiratory muscle was lower in COPD patients than healthy subjects (7.61±2.06 vs 20.42±10.81, respectively, p = 0.0002), and decreased with increasing COPD severity (r = 0.78, p<0.001, between efficiency of the mechanical activation at incremental ventilatory effort and FEV1). These results suggest that the respiratory muscle mechanomyogram is a good reflection of inspiratory effort and can be used to estimate the efficiency of the mechanical activation of the inspiratory muscles. Both, inspiratory muscle activation and inspiratory muscle mechanical activation efficiency are strongly correlated with the pulmonary function. Therefore, the use of the respiratory muscle mechanomyogram can improve the assessment of inspiratory muscle activation in clinical conditions, contributing to a better understanding of breathing in COPD patients., This work was supported in part by the Secretariat of Universities and Research of the Ministry of Economy and Knowledge of the Generalitat de Catalunya (consolidated research groups GRC 2014 SGR 1569 and 424, and CERCA Programme), the Plan Nacional (SAF2014-54371), and by the Ministry of Economy and Competitiveness of the Spanish Government and the European Regional Development Fund, DPI2015-68820-R (MINECO/FEDER).
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Wearable bioimpedance measurement for respiratory monitoring during inspiratory loading

  • Blanco Almazán, María Dolores
  • Groenendaal, Willemijn
  • Catthoor, Francky
  • Jané Campos, Raimon
Bioimpedance is an unobtrusive noninvasive technique to measure respiration and has a linear relation with volume during normal breathing. The objective of this paper was to assess this linear relation during inspiratory loading protocol and determine the best electrode configuration for bioimpedance measurement. The inspiratory load is a way to estimate inspiratory muscle function and has been widely used in studies of respiratory mechanics. Therefore, this protocol permitted us to evaluate bioimpedance performance under breathing pattern changes. We measured four electrode configurations of bioimpedance and airflow simultaneously in ten healthy subjects using a wearable device and a standard wired laboratory acquisition system, respectively. The subjects were asked to perform an incremental inspiratory threshold loading protocol during the measurements. The load values were selected to increase progressively until the 60% of the subject's maximal inspiratory pressure. The linear relation of the signals was assessed by Pearson correlation (r) and the waveform agreement by the mean absolute percentage error (MAPE), both computed cycle by cycle. The results showed a median greater than 0.965 in r coefficients and lower than 11 % in the MAPE values for the entire population in all loads and configurations. Thus, a strong linear relation was found during all loaded breathing and configurations. However, one out of the four electrode configurations showed robust results in terms of agreement with volume during the highest load. In conclusion, bioimpedance measurement using a wearable device is a noninvasive and a comfortable alternative to classical methods for monitoring respiratory diseases in normal and restrictive breathing., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Study of time-frequency characteristics of single snores: extracting new information for sleep apnea diagnosis

  • Castillo Escario, Yolanda
  • Blanco Almazán, Dolores
  • Cámara, Miguel Ángel
  • Jané Campos, Raimon
Obs tructive sleep apnea (OSA) is a highly prevalent chronic disease, especially in elderly and obese population . Despite constitut ing a huge health and economic problem, most patients remain undiagnosed due to limitations in current strategies. Therefore, it is essential to find cost - effective diagnostic alternatives. One of these novel approaches is the analysis of acoustic snoring signals. Snoring is an early symptom of OSA which carr ies pathophysiological information of high diagnostic value. For this reason, the main objective of this work is to study the characteristics of single snores of different types, from healthy and OSA subjects. To do that, we analyzed snoring signals from p revious databases and developed an experimental protocol to record simulated OSA - related sounds and characterize the response of two commercial tracheal microphones. Automatic programs for filtering, downsampling, event detection and time - frequency analysi s were built in MATLAB. We found that time - frequency maps and spectral parameters (central, mean and peak frequency and energy in the 100 - 500 Hz band) allow distinguishing regular snores of healthy subjects from non - regular snores and snores of OSA subject s. Regarding the two commercial microphones, we f ound that one of them was a suitable snoring sensor, while the other had a too restricted frequency response. Future work shall include a higher number of episode s and subjects , but our study has contributed to show how important the differences between regular and non - regular snores can be for OSA diagnosis, and how much clinically relevant information can be extracted from time - frequency maps and spectral parameters of single snores, Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Chest movement and respiratory volume both contribute to thoracic bioimpedance during loaded breathing

  • Blanco Almazán, María Dolores
  • Groenendaal, Willemijn
  • Catthoor, Francky
  • Jané Campos, Raimon
Bioimpedance has been widely studied as alternative to respiratory monitoring methods because of its linear relationship with respiratory volume during normal breathing. However, other body tissues and fluids contribute to the bioimpedance measurement. The objective of this study is to investigate the relevance of chest movement in thoracic bioimpedance contributions to evaluate the applicability of bioimpedance for respiratory monitoring. We measured airflow, bioimpedance at four electrode configurations and thoracic accelerometer data in 10 healthy subjects during inspiratory loading. This protocol permitted us to study the contributions during different levels of inspiratory muscle activity. We used chest movement and volume signals to characterize the bioimpedance signal using linear mixed-effect models and neural networks for each subject and level of muscle activity. The performance was evaluated using the Mean Average Percentage Errors for each respiratory cycle. The lowest errors corresponded to the combination of chest movement and volume for both linear models and neural networks. Particularly, neural networks presented lower errors (median below 4.29%). At high levels of muscle activity, the differences in model performance indicated an increased contribution of chest movement to the bioimpedance signal. Accordingly, chest movement contributed substantially to bioimpedance measurement and more notably at high muscle activity levels., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Analysis of time delay between bioimpedance and respiratory volume signals under inspiratory loaded breathing

  • Blanco Almazán, María Dolores
  • Groenendaal, Willemijn
  • Catthoor, Francky
  • Jané Campos, Raimon
© 2019 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting /republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works, Bioimpedance is known for its linear relation with volume during normal breathing. For that reason, bioimpedance can be used as a noninvasive and comfortable technique for measuring respiration. The goal of this study is to analyze the temporal behavior of bioimpedance measured in four different electrode configurations during inspiratory loaded breathing. We measured four bioimpedance channels and airflow simultaneously in 10 healthy subjects while incremental inspiratory loads were imposed. Inspiratory loading threshold protocols are associated with breathing pattern changes and were used in respiratory mechanics studies. Consequently, this respiratory protocol allowed us to induce breathing pattern changes and evaluate the temporal relationship of bioimpedance with volume. We estimated the temporal delay between bioimpedance and volume respiratory cycles to evaluate the differences in their temporal behavior. The delays were computed as the lag which maximize the cross-correlation of the signals cycle by cycle. Six of the ten subjects showed delays in at least two different inspiratory loads. The delays were dependent on electrode configuration, hence the appearance of the delays between bioimpedance and volume were conditioned to the location and geometry of the electrode configuration. In conclusion, the delays between these signals could provide information about breathing pattern when breathing conditions change, Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Non-linear HRV analysis to quantify the effects of intermittent hypoxia using an OSA rat model

  • Romero, Daniel
  • Jané Campos, Raimon
© 2019 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting /republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works, In this paper, a non-linear HRV analysis was performed to assess fragmentation signatures observed in heartbeat time series after intermittent hypoxia (IH). Three markers quantifying short-term fragmentation levels, PIP, IALS and PSS, were evaluated on R-R interval series obtained in a rat model of recurrent apnea. Through airway obstructions, apnea episodes were periodically simulated in six anesthetized Sprague-Dawley rats. The number of apnea events per hour (AHI index) was varied during the first half of the experiment while apnea episodes lasted 15 s. For the second part, apnea episodes lasted 5, 10 or 15 s, but the AHI index was fixed. Recurrent apnea was repeated for 15-min time intervals in all cases, alternating with basal periods of the same duration. The fragmentation markers were evaluated in segments of 5 minutes, selected at the beginning and end of the experiment. The impact of the heart and breathing rates (HR and BR, respectively) on the parameter estimates was also investigated. The results obtained show a significant increase (from 5 to 10%, p <; 0.05) in fragmentation measures of heartbeat time series after IH, indicating a clear deterioration of the initial conditions. Moreover, there was a strong linear relationship (r > 0.9) between these markers and BR, as well as with the ratio given by HR/BR. Although fragmentation may be impacted by IH, we found that it is highly dependent on HR and BR values and thus, they should be considered during its calculation or used to normalize the fragmentation estimates, Peer Reviewed, Postprint (published version)
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Novel approach to continuous adventitious respiratory sound analysis for the assessment of bronchodilator response

  • Lozano García, Manuel
  • Fiz, José Antonio|||0000-0002-7044-9714
  • Martínez Rivera, Carlos|||0000-0003-1031-2561
  • Torrents, Aurora
  • Ruiz Manzano, Juan|||0000-0001-7213-7346
  • Jané Campos, Raimon|||0000-0002-6541-8729
Background. A thorough analysis of continuous adventitious sounds (CAS) can provide distinct and complementary information about bronchodilator response (BDR), beyond that provided by spirometry. Nevertheless, previous approaches to CAS analysis were limited by certain methodology issues. The aim of this study is to propose a new integrated approach to CAS analysis that contributes to improving the assessment of BDR in clinical practice for asthma patients. Methods. Respiratory sounds and flow were recorded in 25 subjects, including 7 asthma patients with positive BDR (BDR+), assessed by spirometry, 13 asthma patients with negative BDR (BDR-), and 5 controls. A total of 5149 acoustic components were characterized using the Hilbert spectrum, and used to train and validate a support vector machine classifier, which distinguished acoustic components corresponding to CAS from those corresponding to other sounds. Once the method was validated, BDR was assessed in all participants by CAS analysis, and compared to BDR assessed by spirometry. Results. BDR+ patients had a homogenous high change in the number of CAS after bronchodilation, which agreed with the positive BDR by spirometry, indicating high reversibility of airway obstruction. Nevertheless, we also found an appreciable change in the number of CAS in many BDR- patients, revealing alterations in airway obstruction that were not detected by spirometry. We propose a categorization for the change in the number of CAS, which allowed us to stratify BDR- patients into three consistent groups. From the 13 BDR- patients, 6 had a high response, similar to BDR+ patients, 4 had a noteworthy medium response, and 1 had a low response. Conclusions. In this study, a new non-invasive and integrated approach to CAS analysis is proposed as a high-sensitive tool for assessing BDR in terms of acoustic parameters which, together with spirometry parameters, contribute to improving the stratification of BDR levels in patients with obstructive pulmonary diseases.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Characterization of the microvascular cerebral blood flow response to obstructive apneic events during night sleep

  • Zirak, Peyman|||0000-0002-0331-6292
  • Gregori-Pla, Clara|||0000-0002-6623-0031
  • Blanco, Igor|||0000-0001-7636-1177
  • Fortuna Gutiérrez, Ana Mª|||0000-0002-3619-1609
  • Cotta, Gianluca
  • Bramon, Pau
  • Serra Mochales, Isabel|||0000-0002-2465-8574
  • Mola, Anna
  • Solà-Soler, Jordi|||0000-0002-9904-6062
  • Giraldo, Beatriz|||0000-0002-9910-8577
  • Durduran, Turgut|||0000-0001-5838-1027
  • Mayos, Merce|||0000-0003-3972-3671
Obstructive apnea causes periodic changes in cerebral and systemic hemodynamics, which may contribute to the increased risk of cerebrovascular disease of patients with obstructive sleep apnea (OSA) syndrome. The improved understanding of the consequences of an apneic event on the brain perfusion may improve our knowledge of these consequences and then allow for the development of preventive strategies. Our aim was to characterize the typical microvascular, cortical cerebral blood flow (CBF) changes in an OSA population during an apneic event. Sixteen patients (age , 75% male) with a high risk of severe OSA were measured with a polysomnography device and with diffuse correlation spectroscopy (DCS) during one night of sleep with 1365 obstructive apneic events detected. All patients were later confirmed to suffer from severe OSA syndrome with a mean of apneas and hypopneas per hour. DCS has been shown to be able to characterize the microvascular CBF response to each event with a sufficient contrast-to-noise ratio to reveal its dynamics. It has also revealed that an apnea causes a peak increase of microvascular CBF () at the end of the event followed by a drop () similar to what was observed in macrovascular CBF velocity of the middle cerebral artery. This study paves the way for the utilization of DCS for further studies on these populations.