Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Identificación de sistemas de primer y segundo orden mediante control basado en reset, Identification of first and second order systems by reset control

  • Zaragoza, S.
  • Sanchez, J.
  • Baños, A.
[EN] The article presents a method for the identification of first and second order processes with time delay using reset controllers in the absence of disturbances. The method is based on compliance with the method of harmonic balance, which implies the use of an approximation of the control reset by its describing function. The FORE controller (First Order Reset Element) with fixed bandwidth has been chosen because it is the easiest reset driver that possesses all the inherent characteristics in this type of drivers and its descriptive function depends on the amplitude and frequency of its sinusoidal signal input. On the other hand, the fact that the behavior of this reset driver depends on of its reset band allows studying the impact of this parameter in the identification process and in its accuracy., [ES] El artículo presenta un método para la identificación de plantas de primer y segundo orden con retardo usando controladores reseteados en ausencia de perturbaciones. El método se basa en el cumplimiento del principio de equilibrio armónico, lo que implica el uso de una aproximación del controlador reseteado mediante su función descriptiva. Para la realización de este trabajo se ha elegido el controlador FORE (First Order Reset Element) con banda de reset porque es el controlador reseteado que posee todas las características intrínsecas de este tipo de controladores y presenta una función descriptiva que depende de la amplitud y frecuencia de la señal sinusoidal de su entrada. Por otro lado, el que el comportamiento de este controlador dependa de la anchura de la banda de reset que se haya fijado permite estudiar el impacto de este parámetro en el proceso de identificación y en su precisión., Este trabajo ha sido realizado parcialmente gracias al apoyo del Ministerio de Economía y Competitividad de España a través de los fondos asignados a los proyectos DPI2017-84259-C2-2-R y DPI2016-79278-C2-1-R.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Control PID multivariable de una caldera de vapor, Multivariable PID Control of a Boiler

  • Mercader, P.
  • Cánovas, C. D.
  • Baños, A.
[EN] This document presents the proposal of the authors to the Control Engineering Benchmark 2016, organized by the Control Engineering Group of the Spanish Committee of Automatica. This is the winner design in the postgraduate category. The benchmark proposes the design of a control system for a boiler, that is modelled by a nonlinear multivariable model with three input, three output, and a measurable disturbance. The control system presented in this report is based on the design of a multivariable proportional-integral-derivative (PID) controller by using convex optimization techniques. In addition, prefilters for the references and for the measurable disturbance have also been proposed. Finally, the performance of the designed control system is shown under the same scenarios to the ones considered in the benchmark., [ES] Este documento presenta la propuesta de los autores para el Concurso en Ingeniería de Control 2016 (CIC2016) organizado por el Grupo Temático de Ingeniería de Control del Comité Español de Automática (CEA). Esta propuesta resultó ganadora en la categoría de estudiantes de máster y postgrado. El concurso consiste en el diseño de un sistema de control para una caldera de vapor, que es modelada por un modelo no lineal multivariable con tres entradas, tres salidas y una perturbación medible. El sistema de control propuesto en este documento se basa en el diseño de un controlador tipo proporcional integrador derivativo (PID) multivariable, mediante técnicas de optimización convexa. Además, se contempla el uso de más grados de libertad mediante el diseño de precompensadores para referencias y para la perturbación medible. Finalmente, se analiza el desempeño del sistema de control diseñado, bajo los escenarios propuestos en el concurso., Este trabajo está financiado por el Ministerio de Economía e Innovación de España (incluyendo cofinanciación FEDER-UE) bajo los proyectos DPI2013-47100-C2-1-P y DPI2016-79278-C2-1-R.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Reset control of boost converters

  • Nair, Unnikrishnan Raveendran
  • Costa Castelló, Ramon
  • Baños, Alfonso
Trabajo presentado en la Annual American Control Conference (ACC), celebrada en Milwaukee (WI, USA), del 27 al 29 de junio de 2018, The goal of this work is to apply the framework of reset systems, in particular PI+CI controllers, in the controller design for power converters. While the PI+CI controller has been applied in several industrial applications, the application of such controllers in fast electrical systems especially power electronic converters appears to be new. The main motivations for this proposal are performance superiority of these controllers and the ability to produce a fast flat response without any overshoot for a step input. Another factor that influenced the use of such controller is the relatively simple design equations, which enables plug and play capability. The flat responses are highly interesting from the perspective of power converters especially when they are connected to power grids., This work was partially supported, including FEDER co-funding, by the Spanish Ministerio de Educacin project DPI2015-69286-C3-2-R (MINECO/FEDER), project DPI2013-47100-C2-1-P, and project DPI2016- 79278-C2-1-R, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Grid voltage regulation using a reset PI+CI controller for energy storage systems

  • Nair, Unnikrishnan Raveendran
  • Costa Castelló, Ramon
  • Baños, Alfonso
Hybrid controllers are capable of improved performance over their linear counterparts. In particular, reset controllers like the PI+CI are capable of fast flat response for lag dominant plants. Grid connected power converters especially interfacing energy storage systems to grids are required to have fast response to varying load demands to ensure minimum variation in grid parameters. Application of PI+CI controllers in such systems can improve their performance. In this work the improvement brought about by use of PI+CI controller employed for energy storage system power converters is highlighted by comparing it with PI controller based system under load variations. A DC microgrid with Fuel cell-supercapacitor based storage elements are considered here. The design criteria and simulation results are presented here., This work was partially supported, including FEDER co-funding, by the Spanish Ministerio de Educacin project DPI2015-69286-C3-2-R (MINECO/FEDER), project DPI2013-47100-C2-1-P, and project DPI2016- 79278-C2-1-R. This work is supported by the Spanish State Research Agency through the Mara de Maeztu Seal of Excellence to IRI (MDM-2016-0656). This work is partially funded by AGAUR of Generalitat de Catalunya through the Advanced Control Systems (SAC) group grant (2017 SGR 482), Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Reset control for DC-DC converters: an experimental application

  • Nair, Unnikrishnan Raveendran
  • Costa Castelló, Ramon
  • Baños, Alfonso
Power converters in grid connected systems are required to have fast response to ensure the stability of the system. The standard PI controllers used in most power converters are capable of fast response but with significant overshoot. In this paper a hybrid control technique for power converter using a reset PI + CI controller is proposed. The PI + CI controller can overcome the limitation of its linear counterpart (PI) and ensure a fast flat response for power converter. The design, stability and cost of feedback analysis for a DC-DC boost converter employing a PI + CI controller is explored in this work. The simulation and experimental results which confirm the fast, flat response will be presented and discussed., This work was supported in part by the European Union’s Horizon 2020 Research and Innovation Programme under the Marie Skłodowska Curie under Grant 675318 (INCITE), in part by the Spanish State Research Agency through the Mara de Maeztu Seal of Excellence to IRI under Grant MDM-2016-0656, and in part by the Government of Spain under Project DPI2016-79278-C2-1-R, MICAPEM (ref. DPI2015- 69286-C3-2-R, MINECO/FEDER).