Pasar al contenido principal

CARACTERIZACION CLINICA, RADIOLOGICA Y ANALITICA DEL PACIENTE CON ARTROSIS DE RODILLA Y NECESIDAD DE ARTROPLASTIA

DPI2016-80283-C2-2-R

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos I+D+i Retos de Investigación
Año convocatoria 2016
Plan Estatal 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario FUNDACIO INSTITUT HOSPITAL DEL MAR D'INVESTIGACIONS MEDIQUES

Resultados relacionados

Resultados totales (Incluyendo duplicados): 6
Encontrada(s) 1 página(s)

Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Relationship between the choice of clinical treatment, gait functionality and kinetics in patients with comparable knee osteoarthritis

  • Tassani, Simone
  • Tío, Laura
  • Castro Domínguez, Francisco
  • Monfort, Jordi
  • Monllau García, Juan Carlos
  • González Ballester, Miguel Ángel, 1973-
  • Noailly, Jérôme
Objective: The objective of this study was to investigate the relationship between the choice of clinical treatment, gait functionality, and kinetics in patients with comparable knee osteoarthritis. Design: This was an observational case-control study. Setting: The study was conducted in a university biomechanics laboratory. Participants: Knee osteoarthritis patients were stratified into the following groups: clinical treatment (conservative/total knee replacement (TKR) planned), sex (male/female), age (60-67/68-75), and body mass index (BMI) (<30/≥30). All patients had a Kellgren-Lawrence score of 2 or 3 (N = 87). Main Outcome Measures: All patients underwent gait analysis, and two groups of dependent variables were extracted: • Spatiotemporal gait variables: gait velocity, stride time, and double-support time, which are associated with patient functionality. • Kinetic gait variables: vertical, anterior-posterior, and mediolateral ground reaction forces, vertical free moment, joint forces, and moments at the ankle, knee, and hip. Multifactorial and multivariate analyses of variance were performed. Results: Functionality relates to treatment decisions, with patients in the conservative group walking 25% faster and spending 24% less time in the double-support phase. However, these differences vary with age and are reduced in older subjects. Patients who planned to undergo TKR did not present higher knee forces, and different joint moments between clinical treatments depended on the age and BMI of the subjects. Conclusions: Knee osteoarthritis is a multifactorial disease, with age and BMI being confounding factors. The differences in gait between the two groups were mitigated by confounding factors and risk factors, such as being a woman, elderly, and obese, reducing the variability of the gait compression loads. These factors should always be considered in gait studies of patients with knee osteoarthritis to control for confounding effects., Funds from the Spanish Government (HOLOA-DPI2016-80283-C2-1/2-R, RYC-2015-18888, MDM-2015-0502) and from DTIC-UPF are acknowledged.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Parametric finite element model of medial patellofemoral ligament reconstruction model development and clinical validation

  • Sanchis-Alfonso, Vicente
  • Alastruey-López, Diego
  • Ginovart, Gerard
  • Montesinos-Berry, Erik
  • García-Castro, Fabio
  • Ramírez-Fuentes, Cristina
  • Monllau, Joan Carles
  • Alberich-Bayarri, Ángel
  • Pérez, María Ángeles
Background: Currently, there is uncertainty regarding the long-term outcome of medial patellofemoral ligament reconstructions (MPFLr). Our objectives were: (1) to develop a parametric model of the patellofemoral joint (PFJ) enabling us to simulate different surgical techniques for MPFLr; (2) to determine the negative effects on the PFJ associated with each technique, which could be related to long-term deterioration of the PFJ. Methods: A finite element model of the PFJ was created based on CT data from 24 knees with chronic lateral patellar instability. Patella contact pressure and maximum MPFL-graft stress at five angles of knee flexion (0, 30, 60, 90 and 120°) were analysed in three types of MPFLr: anatomic, non-anatomic with physiometric behaviour, and non-anatomic with non-physiometric behaviour. Results: An increase in patella contact pressure was observed at 0 and 30° of knee flexion after both anatomic and non-anatomic MPFLr with physiometric behaviour. In both reconstructions, the ligament was tense between 0 and 30° of knee flexion, but at 60, 90 and 120°, it had no tension. In the third reconstruction, the behaviour was completely the opposite. Conclusion: A parametric model of the PFJ enables us to evaluate different types of MPFLr throughout the full range of motion of the knee, regarding the effect on the patellofemoral contact pressure, as well as the kinematic behaviour of the MPFL-graft and the maximum MPFL-graft stress.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Evaluation of patellar contact pressure changes after static versus dynamic medial patellofemoral ligament reconstructions using a finite element model

  • Sanchis-Alfonso, Vicente
  • Ginovart, Gerard
  • Alastruey-López, Diego
  • Montesinos-Berry, Erik
  • Monllau, Joan Carles
  • Alberich-Bayarri, Ángel
  • Pérez, María Ángeles
Objectives: To evaluate the effect of various medial patellofemoral ligament (MPFL) fixation techniques on patellar pressure compared with the native knee. Methods: A finite element model of the patellofemoral joint consisting of approximately 30, 700 nodes and 22, 200 elements was created from computed tomography scans of 24 knees with chronic lateral patellar instability. Patellar contact pressures and maximum MPFL graft stress at five positions of flexion (0 degrees, 30 degrees, 60 degrees, 90 degrees, and 120 degrees) were analyzed in three types of MPFL reconstruction (MPFLr): (1) static/anatomic, (2) dynamic, using the adductor magnus tendon (AMT) as the femoral fixation, and (3) dynamic, using the quadriceps tendon as the attachment (medial quadriceps tendon-femoral ligament (MQTFL) reconstruction). Results: In the static/anatomic technique, the patellar contact pressures at 0 degrees and 30 degrees were greater than in the native knee. As in a native knee, the contact pressures at 60 degrees, 90 degrees, and 120 degrees were very low. The maximum MPFL graft stress at 0 degrees and 30 degrees was greater than in a native knee. However, the MPFL graft was loose at 60 degrees, 90 degrees, and 120 degrees, meaning it had no tension. In the dynamic MPFLr using the AMT as a pulley, the patellar contact pressures were like those of a native knee throughout the entire range of motion. However, the maximum stress of the MPFL graft at 0 degrees was less than that of a native ligament. Yet, the maximum MPFL graft stress was greater at 30 degrees than in a native ligament. After 30 degrees of flexion, the MPFL graft loosened, similarly to a native knee. In the dynamic MQTFL reconstruction, the maximum patellar contact pressure was slightly greater than in a normal knee. The maximum stress of the MPFL graft was much greater at 0 degrees and 30 degrees than that of a native MPFL. After 30 degrees of flexion, the MQPFL graft loosened just as in the native knee. Conclusions: The patellar contact pressures after the dynamic MPFLr were like those of the native knee, whereas a static reconstruction resulted in greater pressures, potentially increasing the risk of patellofemoral osteoarthritis in the long term. Therefore, the dynamic MPFLr might be a safer option than a static reconstruction from a biomechanical perspective.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Relationship between the choice of clinical treatment, gait functionality and kinetics in patients with comparable knee osteoarthritis

  • Tassani, Simone
  • Tío, Laura
  • Castro Domínguez, Francisco
  • Monfort, Jordi
  • Monllau García, Juan Carlos
  • González Ballester, Miguel Ángel, 1973-
  • Noailly, Jérôme
Objective: The objective of this study was to investigate the relationship between the choice of clinical treatment, gait functionality, and kinetics in patients with comparable knee osteoarthritis. Design: This was an observational case-control study. Setting: The study was conducted in a university biomechanics laboratory. Participants: Knee osteoarthritis patients were stratified into the following groups: clinical treatment (conservative/total knee replacement (TKR) planned), sex (male/female), age (60-67/68-75), and body mass index (BMI) (<30/≥30). All patients had a Kellgren-Lawrence score of 2 or 3 (N = 87). Main Outcome Measures: All patients underwent gait analysis, and two groups of dependent variables were extracted: • Spatiotemporal gait variables: gait velocity, stride time, and double-support time, which are associated with patient functionality. • Kinetic gait variables: vertical, anterior-posterior, and mediolateral ground reaction forces, vertical free moment, joint forces, and moments at the ankle, knee, and hip. Multifactorial and multivariate analyses of variance were performed. Results: Functionality relates to treatment decisions, with patients in the conservative group walking 25% faster and spending 24% less time in the double-support phase. However, these differences vary with age and are reduced in older subjects. Patients who planned to undergo TKR did not present higher knee forces, and different joint moments between clinical treatments depended on the age and BMI of the subjects. Conclusions: Knee osteoarthritis is a multifactorial disease, with age and BMI being confounding factors. The differences in gait between the two groups were mitigated by confounding factors and risk factors, such as being a woman, elderly, and obese, reducing the variability of the gait compression loads. These factors should always be considered in gait studies of patients with knee osteoarthritis to control for confounding effects., Funds from the Spanish Government (HOLOA-DPI2016-80283-C2-1/2-R, RYC-2015-18888, MDM-2015-0502) and from DTIC-UPF are acknowledged.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Parametric finite element model of medial patellofemoral ligament reconstruction model development and clinical validation

  • Sanchis-Alfonso, Vicente|||0000-0002-9191-796X
  • Alastruey-López, Diego
  • Ginovart, Gerard
  • Montesinos-Berry, Erik
  • García-Castro, Fabio
  • Ramírez-Fuentes, Cristina
  • Monllau García, Joan Carles|||0000-0002-2418-4874
  • Alberich-Bayarri, Angel
  • Pérez, María Angeles|||0000-0002-2901-4188
Background: Currently, there is uncertainty regarding the long-term outcome of medial patellofemoral ligament reconstructions (MPFLr). Our objectives were: (1) to develop a parametric model of the patellofemoral joint (PFJ) enabling us to simulate different surgical techniques for MPFLr; (2) to determine the negative effects on the PFJ associated with each technique, which could be related to long-term deterioration of the PFJ. Methods: A finite element model of the PFJ was created based on CT data from 24 knees with chronic lateral patellar instability. Patella contact pressure and maximum MPFL-graft stress at five angles of knee flexion (0, 30, 60, 90 and 120°) were analysed in three types of MPFLr: anatomic, non-anatomic with physiometric behaviour, and non-anatomic with non-physiometric behaviour. Results: An increase in patella contact pressure was observed at 0 and 30° of knee flexion after both anatomic and non-anatomic MPFLr with physiometric behaviour. In both reconstructions, the ligament was tense between 0 and 30° of knee flexion, but at 60, 90 and 120°, it had no tension. In the third reconstruction, the behaviour was completely the opposite. Conclusion: A parametric model of the PFJ enables us to evaluate different types of MPFLr throughout the full range of motion of the knee, regarding the effect on the patellofemoral contact pressure, as well as the kinematic behaviour of the MPFL-graft and the maximum MPFL-graft stress.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Fibronectin-coating enhances attachment and proliferation of mesenchymal stem cells on a polyurethane meniscal scaffold

  • Arredondo, Raquel
  • Poggioli, Francesco|||0000-0002-4787-9687
  • Martínez-Díaz, Santos
  • Piera-Trilla, María
  • Torres-Claramunt, Raúl|||0000-0002-3097-2439
  • Tío Barrera, Laura|||0000-0003-1408-7381
  • Monllau García, Joan Carles|||0000-0002-2418-4874
Partial meniscectomy is one of the most common surgical strategy for a meniscal injury, but sometimes, patients complain of knee pain due to an overload in the ablated compartment. In these cases, implantation of tissue engineering scaffold could be indicated. Currently, two commercial scaffolds, based on collagen or polycaprolactone-polyurethane (PCL-PU), are available for meniscus scaffolding. In short term follow-up assessments, both showed clinical improvement and tissue formation. However, long-term studies carried out in PCL-PU showed that the new tissue decreased in volume and assumed an irregular shape. Moreover, in some cases, the scaffold was totally reabsorbed, without new tissue formation. Mesenchymal stem cells (MSCs) combined with scaffolds could represents a promising approach for treating meniscal defects because of their multipotency and self-renewal. In this work, we aimed to compare the behaviour of MSCs and chondrocytes on a PCL-PU scaffold in vitro. MSCs express integrins that binds to fibronectin (FN), so we also investigate the effect of a FN coating on the bioactivity of the scaffold. We isolated rabbit bone marrow MSCs (rBM-MSCs) from two skeletally mature New Zealand white rabbits and stablished the optimum culture condition to expand them. Then, they were seeded over non-coated and FN-coated scaffolds and cultured in chondrogenic conditions. To evaluate cell functionality, we performed an MTS assay to compare cell proliferation between both conditions. Finally, a histologic study was performed to assess extracellular matrix (ECM) production in both samples, and to compare them with the ones obtained with rabbit chondrocytes (rCHs) seeded in a non-coated scaffold. A culture protocol based on low FBS concentration was set as the best for rBM-MSCs expansion. The MTS assay revealed that rBM-MSCs seeded on FN-coated scaffolds have more cells on proliferation (145%; 95% CI: 107%-182%) compared with rBM-MSCs seeded on non-coated scaffolds. Finally, the histologic study demonstrated that rCHs seeded on non-coated scaffolds displayed the highest production of ECM, followed by rBM-MSCs seeded on FN-coated scaffolds. Furthermore, both cell types produced a comparable ECM pattern. These results suggest that MSCs have low capacity attachment to PCL-PU scaffolds, but the presence of integrin alpha5beta1 (FN-receptor) in MSCs allows them to interact with the FN-coated scaffolds. These results could be applied in the design of scaffolds, and might have important clinical implications in orthopaedic surgery of meniscal injuries.