Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Experimental validations of a tunable-lens-based visual demonstrator of multifocal corrections

  • Akondi, Vyas
  • Sawides, L.
  • Marrakchi, Y.
  • Gambra, Enrique
  • Marcos, Susana
  • Dorronsoro, Carlos
16 pags., 8 figs. 2 tabs., The Simultaneous Vision simulator (SimVis) is a visual demonstrator of multifocal lens designs for prospective intraocular lens replacement surgery patients and contact lens wearers. This programmable device employs a fast tunable lens and works on the principle of temporal multiplexing. The SimVis input signal is tailored to mimic the optical quality of the multifocal lens using the theoretical SimVis temporal profile, which is evaluated from the through-focus Visual Strehl ratio metric of the multifocal lens. In this paper, for the first time, focimeter-verified on-bench validations of multifocal simulations using SimVis are presented. Two steps are identified as being critical to accurate SimVis simulations. Firstly, a new iterative approach is presented that improves the accuracy of the theoretical SimVis temporal profile for three different multifocal intraocular lens designs – diffractive trifocal, refractive segmented bifocal, and refractive extended depth of focus, while retaining a low sampling. Secondly, a fast focimeter is used to measure the step response of the tunable lens, and the input signal is corrected to include the effects of the transient behavior of the tunable lens. It was found that the root-mean-square of the difference between the estimated through-focus Visual Strehl ratio of the multifocal lens and SimVis is not greater than 0.02 for all the tested multifocal designs., Consejería de Educación, Juventud y Deporte of Comunidad de Madrid and the People Programme (Marie Curie Actions) of the European Union’s Seventh Framework Programme (FP7/2007-2013) (n 291820 to VA); EU H2020 SME Innovation Associate (GA-739882); Spanish Government Torres-Quevedo Program (PTQ-15-07432); EIT Health (2017 HS PoC Spain 05); Ministerio de Economía y Competitividad (DTS16-00127); ERC (ERC-2011-AdC 294099); Spanish Government (FIS2014-56643-R, FIS2017-84753-R)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Multifocal contact lens vision simulated with a clinical binocular simulator

  • Barcala, Xoana
  • Viñas, María
  • Ruiz, Sofia
  • Hidalgo, Fernando
  • Nankivil, Derek
  • Karkkainen, Tom
  • Gambra, Enrique
  • Dorronsoro, Carlos
  • Marcos, Susana
Artículo con 10 figuras, Purpose: The purpose of this study is to compare the binocular visual perception of participants wearing multifocal contact lenses and these same lens designs viewed through a temporal multiplexing visual simulator. Methods: Visual performance and perceived visual quality at various distances were obtained in 37 participants wearing soft M−CLs and through the SimVis Gekko programmed with the same lenses. In a pilot study (n = 10) visual performance was measured in terms of LogMAR visual acuity (VA) at far (4 m), intermediate (64 cm) and near (40 cm) distances and through-focus VA (TFVA) curves with the simulated M−CLs. In the follow-up study (n = 27), LogMAR VA at far, intermediate and near distances were measured both with the actual and simulated M−CLs. Perceived visual quality was measured in both studies using the Multifocal Acceptance Score (MAS-2EV), and a Participants Reported Outcomes Vision questionnaire. Differences between the metrics obtained with simulated and actual lenses were obtained. Results: Both actual and simulated M−CLs increased depth-of-focus by a similar amount. Mean LogMAR VA differences with actual and simulated M−CLs ranged between 4 and 6 letters (0.08 ± 0.01, 0.12 ± 0.01 and 0.10 ± 0.01, for far, intermediate and near distances, respectively). MAS-2EV average score differences with actual and simulated M−CLs ranged between −1.00 and + 4.25. Average MAS-2EV scores were not correlated significantly with VA. However, MAS-2EV (average and individual scores) were highly correlated to visual quality questionnaire responses (p < 0.005). Conclusions: A simultaneous vision simulator accurately represented vision with M−CLs both VA at various distances and perceived visual quality, as measured in a clinical setting. The MAS-2EV metric accurately captured participant reported outcomes of standard vision questionnaires. The combination of SimVis Gekko and MAS-2EV has the potential to largely reduce chair time in M−CLs fitting., This research has received funding from the European Research Council under the IMCUSTOMEYE Ref. 779,960 H2020 - EU.2.1.1. In- dustrial Leadership to SM; SILK-EYE Ref. 833,106 Excellent Science – ERC to SM; and the H2020-MSCA-IF-GF-2019-MYOMICRO-893557 to MV. National Eye Institute P30 Core Grant EY001319-46 (Center for Visual Science) and Unrestricted grant Research to Prevent Blindness (Flaum Eye Institute) to SM. This research was supported also from the Spanish Government under the Spanish Government Grant FIS2017- 84753-R to SM, and ISCIII DTS16/00127 to CD; Madrid Regional Gov- ernment IND2017/BMD7670 to XB; and Master Clinical Research Agreement between Johnson and Johnson Vision Care (USA), 2Eye- sVision, Centro Boston de Optometría and IO-CISC