Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 6
Encontrada(s) 1 página(s)

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Detection, size characterization and quantification of silver nanoparticles in consumer products by particle collision coulometry

  • Hernández, D.
  • Vidal, J.C.
  • Laborda, F.
  • Pérez-Arantegui, J.
  • Giménez-Ingalaturre, A.C.
  • Castillo, J.R.
Silver nanoparticles (AgNPs) are widely used in industrial and consumer products owing to its antimicrobial nature and multiple applications. Consequently, their release into the environment is becoming a big concern because of their negative impacts on living organisms. In this work, AgNPs were detected at a potential of + 0.70 V vs. Ag/AgCl reference electrode, characterized, and quantified in consumer products by particle collision coulometry (PCC). The electrochemical results were compared with those measured with electron microscopy and single-particle inductively coupled plasma mass spectrometry. The theoretical and practical peculiarities of the application of PCC technique in the characterization of AgNPs were studied. Reproducible size distributions of the AgNPs were measured in a range 10–100 nm diameters. A power allometric function model was found between the frequency of the AgNPs collisions onto the electrode surface and the number concentration of nanoparticles up to a silver concentration of 1010 L-1 (ca. 25 ng L-1 for 10 nm AgNPs). A linear relationship between the number of collisions and the number concentration of silver nanoparticles was observed up to 5 × 107 L-1. The PCC method was applied to the quantification and size determination of the AgNPs in three-silver containing consumer products (a natural antibiotic and two food supplements). The mean of the size distributions (of the order 10–20 nm diameters) agrees with those measured by electron microscopy. Graphical abstract: [Figure not available: see fulltext.].
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Silver nanoparticles-clays nanocomposites as feed additives: Characterization of silver species released during in vitro digestions. Effects on silver retention in pigs

  • Abad-Alvaro, I.
  • Trujillo, C.
  • Bolea, E.
  • Laborda, F.
  • Fondevila, M.
  • Latorre, M.A.
  • Castillo, J.R.
Two different clay nanocomposites, as sepiolite-Ag and kaolinite-Ag, are studied as carriers for silver nano particles (AgNPs) oral administration as antimicrobial agent in additives for animal feed. A three-step digestibility assay, corresponding to stomach, small and large intestine simulations, has been followed. Ultrafiltration and asymmetrical flow field-flow fractionation (AF4) coupled to UV-Vis absorption and ICPMS detectors have been used for size characterisation of the silver species released during the in vitro digestibility assays. Less than 1% of the total silver is released in the stomach simulation step, probably due to the formation of silver chloride on the nanocomposite surface. In the case of the intestine simulation, silver released increases and tends to form complexes with the enzymes present in the media. A larger amount of silver was released from kaolinite-Ag compared to sepiolite-Ag (17 vs. 7%), probably due to a higher retention rate of silver shown by sepiolite, justified by its sorption capacity and fibrous structure. No evidences were found about a significant release of silver nanoparticles along the in vitro assay from any of the two nanocomposites studied. These results have been compared to the silver levels found in liver and faeces from weaned pigs fed with these supplements for 35 days and followed by basal diet free of silver for 4 weeks in an in vivo assay. Piglets fed with kaolinite-Ag retained more silver in liver than those receiving sepiolite-Ag, and the opposite was observed in faeces, although differences were not statistically significant. Silver levels found in muscles were below the limit of detection (0.009 mu g Ag g(-1)) in all cases.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Catching particles by atomic spectrometry: Benefits and limitations of single particle - inductively coupled plasma mass spectrometry

  • Laborda, Francisco
  • Abad-Álvaro, Isabel
  • Jiménez, María S.
  • Bolea, Eduardo
Single particle inductively coupled plasma mass spectrometry (SP-ICP-MS) has led ICP-MS into a new dimension, turning an ensemble technique for elemental and isotope ratio analysis into a particle counting technique and well beyond. SP-ICP-MS allows the detection of particles, their size characterization and the quantification of their number and mass concentrations, as well as the dissolved forms of the target element(s). Although the technique is mostly applied to metal- and metalloid-based nanoparticles, its application to microparticles and carbon-based particles are emerging. After twenty years since the first publications and more than ten years of ongoing development, SP-ICP-MS has reached a high degree of maturity, with an increasing number of applications in a wide range of fields. Despite this trend, there are aspects related to the fundamentals of the technique that still require further studies. This review is organized around the fundamentals of the technique along with the different steps and processes involved, from the sample introduction to the signal processing, offering an updated view of these topics, focusing on the benefits and current limitations of the technique, as well as its future perspectives.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Exploring the boundaries in the analysis of large particles by single particle inductively coupled plasma mass spectrometry: application to nanoclays

  • Ojeda, D.
  • Bolea, E.
  • Pérez-Arantegui, J.
  • Laborda, F.
The analysis of microparticles by single particle inductively coupled plasma mass spectrometry (SP-ICP-MS) requires sample introduction systems that guarantee transport efficiencies similar to those obtained with dissolved standards across the size range covered. The utilization of a nebulisation system based on a linear pass spray chamber and a micronebuliser is discussed and optimized for the introduction of large inorganic particles. Limitations caused by incomplete ionisation or the counting limit of detectors affecting particle size characterisation are also considered. The procedure developed has been applied to the characterisation of suspensions of a natural clay (kaolinite), with a thickness in the range of a few nanometers and lateral dimensions up to 1 mu m. The application of different sensitivity conditions by the modification of the ion transmission allowed us to cover the whole size range of the suspension monitoring the Al-27 isotope and achieve a quantitative mass recovery with respect to ICP-MS analysis. Finally, the migration of nanoclays (montmorillonite) from food containers and their detection by SP-ICP-MS are presented. The results have been compared to those obtained by TEM, showing that nanoclays migrated from the containers into water.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Detection, quantification, and characterization of polystyrene microplastics and adsorbed bisphenol A contaminant using electroanalytical techniques

  • Vidal, Juan C.
  • Midón, Javier
  • Vidal, Ana B.
  • Ciomaga, Dragos
  • Laborda, Francisco
The potential applications of electroanalytical techniques for the quantification and size characterization of nonelectroactive polystyrene microplastics is reported, in addition to characterizing the kinetics of adsorption of bisphenol A on these polystyrene microparticles. The individual adsorption events of very diluted polystyrene microparticles dispersions on glassy-carbon microelectrodes produce the blocking of the charge transfer of a mediator (ferrocene-methanol) thus decreasing the current of the recorded chronoamperogram in a stepwise manner. The magnitude of the current steps are in the order of pA values and can be related to the diameter of the plastic microparticles in the size range 0.1 to 10 µm. The frequency of the current steps in the domain time used (120 s) allows to quantify the number concentration of these microparticles in the range 0.005 to 0.500 pM. Electrochemical impedance spectroscopy confirms the adsorption of the polystyrene microplastics on carbon microelectrodes (and to a lesser extent on platinum microelectrodes) under the same experimental conditions as above. On the other hand, the adsorbed microplastics become concentrators of other pollutants found in the environment. The sensitive differential-pulse voltammetry determination of bisphenol A (linear range 0.80–15.00 µM; detection limit 0.24 µM) was used together with a simple separation procedure for studying the adsorption of bisphenol A on polystyrene microparticles. The adsorption capacity (mg of bisphenol A retained per g of the polystyrene microplastics) decreased from approximately 5.7 to 0.8 mg g−1 with increasing dosages of polystyrene microparticles from 0.2 to 1.6 g l−1. The adsorption isotherms were modeled resulting in a monolayer of bisphenol A adsorbed on the microplastics (i.e., best fitted to a Langmuir model).
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Comparative study of extraction methods of silver species from faeces of animals fed with silver-based nanomaterials

  • Jiménez, María S.
  • Bakir, Mariam
  • Ben-Jeddou, Khaoula
  • Bolea, Eduardo
  • Pérez-Arantegui, Josefina
  • Laborda, Francisco
Extractions methods based on ultrapure water, tetramethylammonium hydroxide (TMAH), and tetrasodium pyrophosphate (TSPP) were applied to faeces collected from two in vivo experiments of pigs and chickens fed with a silver-based nanomaterial to study the fate and speciation of silver. For TMAH extraction, cysteine and CaCl2 were used to evaluate their stabilization effect on the silver forms. The analytical techniques single-particle inductively coupled plasma mass spectrometry (SP-ICP-MS), hydrodynamic chromatography hyphenated to ICP-MS (HDC-ICP-MS) and asymmetric flow field flow fractionation coupled to ICP-MS (AF4-ICP-MS) were applied to the simultaneous detection of particulate and dissolved silver. Results have shown that water extraction was a suitable option to assess the environmental release of silver, with percentages of 3 and 9% for faeces of pigs and chickens, respectively. The use of TMAH extraction combined with SP-ICP-MS analysis was useful to characterize Ag-containing particles (less than 1%). Both stabilizers, cysteine and CaCl2, have a similar effect on silver nanoparticle preservation for chicken faeces, whereas cysteine-Triton was better for pig samples. In any case, silver extraction efficiency with TMAH was low (39–42%) for both types of faeces due to a matrix effect. TSPP followed by ICP-MS enabled the fractionation of the silver in the faeces, with silver sulphide (41%) and ionic silver (62%) being the most abundant fractions.